Ilde Lorato

Dr. Ilde Lorato

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2019 in Nature Electronics
Verified
Journal Article
Closed access
PDF file
MMMarco Mercuri
Marco Mercuri
ILIlde Lorato
Ilde Lorato
YLYao-Hong Liu
Yao-Hong Liu
FWFokko Wieringa
Fokko Wieringa
CHChris Van Hoof
Chris Van Hoof
TTTom Torfs
Tom Torfs

4 April 2018 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
MMMarco Mercuri
Marco Mercuri
YLYao-Hong Liu
Yao-Hong Liu
ILIlde Lorato
Ilde Lorato
TTTom Torfs
Tom Torfs
FWFokko Wieringa
Fokko Wieringa
CHChris Van Hoof
Chris Van Hoof
A continuous wave Doppler radar, operating as a phase-locked-loop in phase demodulator configuration, is proposed and in vivo demonstrated for noncontact vital signs monitoring. The radar architecture exhibits a unique precision in tracking the phase modulation caused by human cardiopulmonary activity from which heartbeat and respiration can simultaneously be extracted. The single mixer architecture is immune to the null point and does not require small-angle approximation conditions, which distinguishes it from pre-existing other approaches. This enables the proposed radar to behave highly linear, with very precise detection of phase modulations induced by any kind of movement, independently from amplitude and speed. After simulations and technical tests to validate functionality and safety of the proposed architecture, a practical setup was demonstrated on human volunteers. Wavelet independent component analysis was applied to successfully retrieve respiratory and heart rate information from the radar baseband signal.

29 March 2017 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
MMMarco Mercuri
Marco Mercuri
YLYao-Hong Liu
Yao-Hong Liu
ILIlde Lorato
Ilde Lorato
TTTom Torfs
Tom Torfs
ABAndre Bourdoux
Andre Bourdoux
CHChris Van Hoof
Chris Van Hoof
A Doppler radar operating as a Phase-Locked-Loop (PLL) in frequency demodulator configuration is presented and discussed. The proposed radar presents a unique architecture, using a single channel mixer, and allows to detect contactless vital signs parameters while solving the null point issue and without requiring the small angle approximation condition. Spectral analysis, simulations, and experimental results are presented and detailed to demonstrate the feasibility and the operational principle of the proposed radar architecture.

24 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ILIlde Lorato
Ilde Lorato
SSSander Stuijk
Sander Stuijk
MMmohammed meftah
mohammed meftah
DKDeedee Kommers
Deedee Kommers
PAPeter Andriessen
Peter Andriessen
Gerard De HaanGerard De Haan
Gerard De Haan
Aiming at continuous unobtrusive respiration monitoring, motion robustness is paramount. However, some types of motion can completely hide the respiration information and the detection of these events is required to avoid incorrect rate estimations. Therefore, this work proposes a motion detector optimized to specifically detect severe motion of infants combined with a respiration rate detection strategy based on automatic pixels selection, which proved to be robust to motion of the infants involving head and limbs. A dataset including both thermal and RGB (Red Green Blue) videos was used amounting to a total of 43 h acquired on 17 infants. The method was successfully applied to both RGB and thermal videos and compared to the chest impedance signal. The Mean Absolute Error (MAE) in segments where some motion is present was 1.16 and 1.97 breaths/min higher than the MAE in the ideal moments where the infants were still for testing and validation set, respectively. Overall, the average MAE on the testing and validation set are 3.31 breaths/min and 5.36 breaths/min, using 64.00% and 69.65% of the included video segments (segments containing events such as interventions were excluded based on a manual annotation), respectively. Moreover, we highlight challenges that need to be overcome for continuous camera-based respiration monitoring. The method can be applied to different camera modalities, does not require skin visibility, and is robust to some motion of the infants.

14 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Israel Campero JuradoIsrael Campero Jurado
Israel Campero Jurado
ILIlde Lorato
Ilde Lorato
JTJohn Fredy Morales Tellez
John Fredy Morales Tellez
LFLonneke Fruytier
Lonneke Fruytier
SSShavini Stuart
Shavini Stuart
ABAarnout Brombacher
Aarnout Brombacher
Cardiovascular diseases (CVD) represent a serious health problem worldwide, of which atrial fibrillation (AF) is one of the most common conditions. Early and timely diagnosis of CVD is essential for successful treatment. When implemented in the healthcare system this can ease the existing socio-economic burden on health institutions and government. Therefore, developing technologies and tools to diagnose CVD in a timely way and detect AF is an important research topic. ECG monitoring patches allowing ambulatory patient monitoring over several days represent a novel technology, while we witness a significant proliferation of ECG monitoring patches on the market and in the research labs, their performance over a long period of time is not fully characterized. This paper analyzes the signal quality of ECG signals obtained using a single-lead ECG patch featuring self-adhesive dry electrode technology collected from six cardiac patients for 5 days. In particular, we provide insights into signal quality degradation over time, while changes in the average ECG quality per day were present, these changes were not statistically significant. It was observed that the quality was higher during the nights, confirming the link with motion artifacts. These results can improve CVD diagnosis and AF detection in real-world scenarios.

3 August 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
ILIlde Lorato
Ilde Lorato
SSSander Stuijk
Sander Stuijk
MMMohammed Meftah
Mohammed Meftah
DKDeedee Kommers
Deedee Kommers
PAPeter Andriessen
Peter Andriessen
GHGerard de Haan
Gerard de Haan
Respiration is monitored in neonatal wards using chest impedance (CI), which is obtrusive and can cause skin damage to the infants. Therefore, unobtrusive solutions based on infrared thermography are being investigated. This work proposes an algorithm to merge multiple thermal camera views and automatically detect the pixels containing respiration motion or flow using three features. The method was tested on 152 minutes of recordings acquired on seven infants. We performed a comparison with the CI respiration rate yielding a mean absolute error equal to 2.07 breaths/min. Merging the three features resulted in reducing the dependency on the window size typical of spectrum-based features.