Tabea Nikola Schmidt

Ms. Tabea Nikola Schmidt

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
LRLarissa Rosenbaum
Larissa Rosenbaum
MFMartin Freesmeyer
Martin Freesmeyer
TSTabea Nikola Schmidt
Tabea Nikola Schmidt
Christian KühnelChristian Kühnel
Christian Kühnel
FGFalk Gühne
Falk Gühne
PSPhilipp Seifert
Philipp Seifert
Background/Objectives: Autonomously functioning thyroid nodules (AFTNs) are most frequently diagnosed as benign. However, they show high ratings in ultrasound (US) risk stratification systems (RSSs) that utilize the current clinical standard methodology of conventional static image capture (SIC) documentation. The objective of this study was to evaluate the RSS ratings and respective fine needle cytology (FNC) recommendations of cine loop (CL) video sequences in comparison to SIC. Methods: 407 patients with 424 AFTNs were enrolled in this unicentric, retrospective study between 11/2015 and 11/2023. Recorded US CL and SIC were analyzed lesion-wise and compared regarding US features, Kwak and ACR TIRADS, ACR FNC recommendations, as well as assessment difficulties and artifacts. Statistical analyses were conducted using the Chi2 test and Spearman’s correlation coefficient in SPSS software. p-values < 0.05 were considered significant. Results: Strong to very strong correlations were observed for all US features, RSS ratings, and ACR FNC recommendations (Spearman’s correlation: each p < 0.001), comparing CL and SIC. For >60% of the AFTNs, ACR FNC recommendation was given. Kwak TIRADS were more consistent with the benign nature of AFTNs than the ACR ratings. CL captured significantly more “echogenic foci” than SIC (Chi2: p < 0.001). Artifacts (poor image quality, acoustic shadowing, sagittal incompletely displayed AFTN) were significantly more common on CL, affecting ~40% of AFTNs, compared to ~15% on SIC (Chi2: each p < 0.05). Weak correlation was observed for assessment confidence between CL and SIC, with SIC outperforming CL (Spearman’s correlation: each p < 0.001). Conclusions: A strong correlation was identified between CL and SIC in terms of RSS ratings and ACR FNC recommendations. Kwak is a superior representative of the benign character of AFTNs than ACR. However, CL provided more detailed information while being associated with decreased observer confidence and more artifacts. Specific operator training and technical improvements, including AI implementation, could improve image quality in future.

1 March 2026 in Radiology
Verified
Journal Article
Closed access
Christian KühnelChristian Kühnel
Christian Kühnel
TSTabea Nikola Schmidt
Tabea Nikola Schmidt
MFMartin Freesmeyer
Martin Freesmeyer
MSMiriam Schricke
Miriam Schricke
LSLeonie Schreiber
Leonie Schreiber
PSPhilipp Seifert
Philipp Seifert
Transarterial radioembolization generally results in low radiation exposure for medical staff; 166 Ho-poly-L-lactic acid microspheres led to the highest body doses, while 90 Y-resin microspheres generated the highest hand doses, with interventional radiologists receiving the highest overall doses.