Thomas Lapauw

Dr. Thomas Lapauw

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Gobinath JegannathanGobinath Jegannathan
Gobinath Jegannathan
VSVolodymyr Seliuchenko
Volodymyr Seliuchenko
TDThomas Van den Dries
Thomas Van den Dries
TLThomas Lapauw
Thomas Lapauw
SBSven Boulanger
Sven Boulanger
MKMaarten Kuijk
Maarten Kuijk
This review paper presents an assortment of research on a family of photodetectors which use the same base mechanism, current assistance, for the operation. Current assistance is used to create a drift field in the semiconductor, more specifically silicon, in order to improve the bandwidth and the quantum efficiency. Based on the detector and application, the drift field can be static or modulated. Applications include 3D imaging (both direct and indirect time-of-flight), optical receivers and fluorescence lifetime imaging. This work discusses the current-assistance principle, the various photodetectors using this principle and a comparison is made with other state-of-the-art photodetectors used for the same application.

5 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MKMaarten Kuijk
Maarten Kuijk
Ayman MorsyAyman Morsy
Ayman Morsy
TLThomas Lapauw
Thomas Lapauw
TDThomas Van den Dries
Thomas Van den Dries
WNWannes Nevens
Wannes Nevens
DNDaniël Van Nieuwenhove
Daniël Van Nieuwenhove
Correlation-Assisted Direct Time-of-Flight (CA-dToF) is demonstrated for the first time on a large 320 × 240-pixel SPAD array sensor that includes on-chip high-speed timing support circuitry. SPAD events are processed in-pixel, avoiding data communication over the array and/or storage bottlenecks. This is accomplished by sampling two orthogonal triangle waves that are synchronized with short light pulses illuminating the scene. Using small switched-capacitor circuits, exponential moving averaging (EMA) is applied to the sampled voltages, delivering two analog voltages (VQ2, VI2). These contain the phase delay, or the time of flight between the light pulse and photon’s time of arrival (ToA). Uncorrelated ambient photons and dark counts are averaged out, leaving only their associated shot noise impacting the phase precision. The QVGA camera allows for capturing depth-sense images with sub-cm precision over a 6 m range of detection, even with a small PDE of 0.7% at an 850 nm wavelength.

7 October 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
MKMaarten Kuijk
Maarten Kuijk
Ayman MorsyAyman Morsy
Ayman Morsy
TLThomas Lapauw
Thomas Lapauw
TDThomas Van den Dries
Thomas Van den Dries
WNWannes Nevens
Wannes Nevens
DNDaniël Van Nieuwenhove
Daniël Van Nieuwenhove
Correlation-Assisted Direct Time-of-Flight (CA-dToF) is demonstrated for the first time with a 320×240-pixel SPAD array. SPAD triggers are processed in-pixel, avoiding data communication over the array and/or storage bottlenecks. This is accomplished by sampling two orthogonal triangle waves that are synchronized with short light pulses illuminating the scene. Using small switched-capacitor circuits, exponential-moving-averaging (EMA) is applied to the sampled voltages, delivering two analog voltages (VQ2, VI2). These contain the phase delay, or the time of flight between the light pulse and photon’s time of arrival (ToA). Uncorrelated ambient photons and dark counts are averaged out, leaving only their associated shot noise impacting the phase precision. The QVGA camera allows capturing depth-sense images with sub-cm precision over 6-m range of detection, even with a small PDE of 0.7% at 850-nm wavelength.

3 July 2025 in IEEE Sensors Letters
Verified
Journal Article
Open access
WNWannes Nevens
Wannes Nevens
TLThomas Lapauw
Thomas Lapauw
Jonathan VrijsenJonathan Vrijsen
Jonathan Vrijsen
TDThomas Van den Dries
Thomas Van den Dries
HIHans Ingelberts
Hans Ingelberts
MKMaarten Kuijk
Maarten Kuijk
A video rate fluorescence lifetime (FLT) imaging system is presented featuring in-pixel lifetime calculation based on the center-of-mass of the times-of-arrival (ToA) of photons received by the single-photon avalanche diode (SPAD) of the pixel. The ToAs of photons received during a gating window placed in the decay of the returned fluorescent emission are averaged by a switched-capacitor circuit, implementing the center-of-mass method (CMM) in a compact pixel circuit. Binning of ToAs or complex time-to-digital circuits are avoided, and instead, optimal use of all received photons is achieved on a small pixel area with low communication and computational overhead. The system is validated through analytical modeling, Monte Carlo simulations, and real-world experiments using fluorophores with known lifetimes, demonstrating agreement with the analytical model and achieving accurate FLT estimations across a large range of photon counts. A dedicated QVGA (320 × 240pixel) image sensor that includes all necessary circuitry for the CMM currently reaches 10 frames per second and demonstrates the real-time FLT imaging capability of the system.

2 September 2024 in IEEE Sensors Letters
Verified
Journal Article
Closed access
Ayman MorsyAyman Morsy
Ayman Morsy
CBCédric Baijot
Cédric Baijot
Gobinath JegannathanGobinath Jegannathan
Gobinath Jegannathan
TLThomas Lapauw
Thomas Lapauw
TDThomas Van den Dries
Thomas Van den Dries
MKMaarten Kuijk
Maarten Kuijk
This letter proposes a novel SPAD-based pixel, designed for direct time-of-flight (dToF) imaging with in-pixel averaging, which provides a promising advancement in low-power and potentially high image resolution for outdoor applications. By utilizing a laser pulse and two orthogonal sinusoidal signals, the pixel averages out the detected ambient light while accumulating the laser pulse round-trip time. A prototype pixel array was fabricated using a 180 nm CMOS process, featuring a commercial SPAD cell. By characterizing one pixel and employing a 100 klux solar emulator as an ambient light source with a fixed 40 ambient-to-signal ratio (ASR) over a 360 $^{\circ }$ phase shift, equivalent to 6 m detection range, the maximum detected accuracy error was 3.3 %, with a 5 cm precision.

20 March 2026 in Biomedical Optics Express
Verified
Journal Article
Closed access
SJSimone Janssen
Simone Janssen
TDThomas Van den Dries
Thomas Van den Dries
NKN. Lina Kheiro
N. Lina Kheiro
TLThomas Lapauw
Thomas Lapauw
JGJeroen De Geeter
Jeroen De Geeter
Sophie HernotSophie Hernot
Sophie Hernot
Indocyanine green (ICG) is used for tumor visualization using fluorescence-intensity imaging, but false-positive signals are common. Fluorescence-lifetime-based tumor identification may overcome this limitation by measuring the time behavior of fluorescent light. However, the optimal time point for fluorescence lifetime imaging after the intravenous administration of ICG is yet to be defined. In this paper, the in vivo time course of ICG is investigated in syngeneic tumor-bearing mice using a novel macroscopic fluorescence lifetime camera. High-dynamic-range images were generated through post-processing, investigated, and subsequently applied for time-domain intensity and lifetime image analysis. The results indicate that fluorescence lifetime imaging may provide higher accuracy in tumor identification than intensity-based imaging, but the optimal imaging time point appears to require a 24-48 hour interval after intravenous injection, similar to intensity measurements. However, earlier time points might be of interest to investigate for liver and intestinal tumors.