In the last five years, the Chilean Ministries of Agriculture and Energy developed a national strategy to incorporate renewable energies into various economic sectors. Since 2013, more than 1500 off-grid solar photovoltaic (PV) systems, with power ranging from 1 kW to 3 kW, were installed to drive existing irrigation systems in small and medium-sized farms for the exportation of fresh fruit. A net billing regulation was also implemented in 2014. This study shows a cost-effective methodology for the sizing of solar PV systems for existing irrigation facilities in Chile, in an effort to improve the competitiveness of the fresh-fruit industry. The same methodology may also be implemented in other Latin American countries. The article presents the analysis of four projects (two in the Atacama Region, and two in the Maule Region). The baseline situation of the four units was studied, as well as the energy-efficient actions that may be applied, in addition to the recommended characteristics of the selected PV system to drive the irrigation systems of small fresh-fruit farms. Off-grid and on-grid solar PV systems were analyzed, including some particularities of the Chilean regulations. The required water demand of the irrigation systems and their corresponding pressure heads were also determined. The electricity demand of the system was calculated, and the PV system was designed for an optimal irrigation system. Additionally, an economical assessment was made for two years. In the first year, the cost effectiveness of energy-efficient actions was evaluated for the irrigation system, and it was found that they had paybacks of approximately two years. In the second year, the implementation of a PV system in each demonstrative unit was evaluated. The on-grid solar PV system performed better than the off-grid system, with evaluated paybacks of approximately 12 years. Finally, some recommendations for a well-designed on-grid solar PV system were made on the basis of it lasting over 25 years, with an adequate operation and maintenance plan.
Ideally, an insulation system must be capable of electrically insulating the active components of a machine or device subjected to high voltages. However, due to the presence of polluting agents or imperfections inside or on the surface of the insulation, small current pulses called partial discharges (PDs) are common, which partially short-circuit the insulation and cause it to lose its insulating properties, and thus its insulation capacity, over time. In some cases, measurements of this phenomenon are limited by the type of sensor used; if it is not adequate, it can distort the obtained results, which can lead to a misdiagnosis of the state of the device. The inductive loop sensor has experimentally been demonstrated to be capable of properly measuring different types of PDs. However, because of its current design, there are several practical limitations on its use in real devices or environments. An example is the presence of a primary conductor located at a fixed distance from the sensor, through which PD pulses must flow for the sensor to capture them. In this article, the sensor’s behavior is studied at different separation distances from the line through which the PD pulses flow. In addition, the measuring capacity of the sensor is tested by removing the presence of the primary conductor and placing the sensor directly over the line through which the PD pulses of a real device flow.
Nowadays, microgrids are gaining importance in electric power generation and distribution environments due to their flexibility, versatility, scalability and the possibility of supplying ancillary services when connected to the grid. They allow for the customization of electric supply for very different types of consumers. Therefore, a new control model for power and energy management based on homeostaticity of electric power systems (EPS) is presented, which has been already analyzed and approved by ENEL Chile in its developmental stage. ENEL, the largest electric utility in the country, is interested in incorporating smart microgrids in the electricity distribution market, as part of a worldwide policy. Such microgrids are to be installed in buildings serviced by ENEL. To demonstrate the model’s utility, a Simulink model of a real microgrid is used, which is comprised of PV generation, energy storage, an air conditioning (AC) equipment and thermal storage of the building upon which the microgrid is installed. The behavior of every element is simulated, including the dynamic thermal model of the building in order to optimize energy management and power supply versus consumption. The behavior of the whole system is analyzed under different environmental profiles and energy consumption patterns using the proposed homeostaticity system.
In this paper a novel model is being proposed and considered by ENEL—the largest electric utility in Chile—and analyzed thoroughly, whereby electric power control and energy management for a 60-apartments’ residential building is presented as an example of the utility’s green energy program, part of its Smart Grid Transformation plan to install grid-tied distributed generation (DG) systems, namely microgrids, with solar generation and energy storage in Santiago, Chile. The particular tariffs scheme analysis shown is part of the overall projected tentative benefits of adopting the new scheme, which will require the utility’s customers to adapt their consumption behavior to the limited supply of renewable energy by changing energy consumption habits and schedules in a way that maximizes the capacity and efficiency of the grid-tied microgrid with energy storage. The change in behavior entails rescheduling power consumption to hours where the energy supply capacity in the DG system is higher and price is lower as well as curtailing their power needs in certain hourly blocks so as to maximize DG system’s efficiency and supply capacity. Nevertheless, the latter presents a problem under the perspective of ENEL’s renewable energy sources (RES) integration plan with the electric utility’s grid supply, which, up until now and due to current electric tariffs law, has not had a clear solution. Under said scenario, a set of strategies based on energy homeostasis principles for the coordination and control of the electricity supply versus customers’ demand has been devised and tested. These strategies which consider various scenarios to conform to grid flexibility requirements by ENEL, have been adapted for the specific needs of these types of customers while considering the particular infrastructure of the network. Thus, the microgrid adjusts itself to the grid in order to complement the grid supply while seeking to maximize green supply capacity and operational efficiency, wherein the different energy users and their energy consumption profiles play a crucial role as “active loads”, being able to respond and adapt to the needs of the grid-connected microgrid while enjoying economic benefits. Simulation results are presented under different tariff options, system’s capacity and energy storage alternatives, in order to compare the proposed strategies with the actual case of traditional grid’s electricity distribution service, where no green energy is present. The results show the advantage of the proposed tariffs scheme, along with power control and energy management strategies for the integration of distributed power generation within ENEL’s Smart Grid Transformation in Chile.
Both in industrial as in controlled environments, such as high-voltage laboratories, pulses from multiple sources, including partial discharges (PD) and electrical noise can be superimposed. These circumstances can modify and alter the results of PD measurements and, what is more, they can lead to misinterpretation. The spectral power clustering technique (SPCT) allows separating PD sources and electrical noise through the two-dimensional representation (power ratio map or PR map) of the relative spectral power in two intervals, high and low frequency, calculated for each pulse captured with broadband sensors. This method allows to clearly distinguishing each of the effects of noise and PD, making it easy discrimination of all sources. In this paper, the separation ability of the SPCT clustering technique when using a Rogowski coil for PD measurements is evaluated. Different parameters were studied in order to establish which of them could help for improving the manual selection of the separation intervals, thus enabling a better separation of clusters. The signal processing can be performed during the measurements or in a further analysis.
13 February 2019 in Periodicals of Engineering and Natural Sciences (PEN)