Mihai Brezeanu

Dr. Mihai Brezeanu

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2025 in Sensors
Verified
Journal Article
Open access
Bogdan ŞerbanBogdan Şerban
Bogdan Şerban
NDNiculae Dumbravescu
Niculae Dumbravescu
Octavian BuiuOctavian Buiu
Octavian Buiu
MBMarius Bumbac
Marius Bumbac
CDCarmen Dumbravescu
Carmen Dumbravescu
OBOana Brincoveanu
Oana Brincoveanu
This paper reports several preliminary investigations concerning the relative humidity (RH) detection response of a chemiresistive sensor that uses a novel sensing layer based on pristine carbon nano-onions (CNOs) and polyvinyl alcohol (PVA) at a 1/1 and 2/1 w/w ratio. The sensing device, including a Si/SiO2 substrate and gold electrodes, is obtained by depositing the CNOs–PVA aqueous suspension on the sensing structure by drop casting. The composition and morphology of the sensing film are explored by means of scanning electron microscopy, Raman spectroscopy, atomic force microscopy, and X-ray diffraction. The manufactured sensor’s room temperature RH detection performance is examined by applying a continuous flow of the electric current between the interdigitated electrodes and measuring the voltage as the RH varies from 5% to 95%. For RH below 82% (sensing layer based on CNOs–PVA at 1/1 w/w ratio) or below 50.5% (sensing layer based on CNOs–PVA at 2/1 w/w ratio), the resistance varies linearly with RH, with a moderate slope. The newly developed sensor, using CNOs–PVA at a 1:1 ratio (w/w), responded as well as or better than the reference sensor. At the same time, the recorded recovery time was about 30 s, which is half the recovery time of the reference sensor. Additionally, the changes in resistance (ΔR/ΔRH) for different humidity levels showed that the CNOs–PVA layer at 1:1 was more sensitive at humidity levels above 80%. The main RH sensing mechanisms considered and discussed are the decrease in the hole concentration in the CNOs during the interaction with an electron donor molecule, such as water, and the swelling of the hydrophilic PVA. The experimental RH detection data are analyzed and compared with the RH sensing results reported in previously published work on RH detectors employing sensing layers based on oxidized carbon nanohorns–polyvinylpirrolidone (PVP), oxidized carbon nanohorns–PVA and CNOs–polyvinylpyrrolidone.

1 April 2007 in Diamond and Related Materials
Verified
Journal Article
Closed access
MBMihai Brezeanu
Mihai Brezeanu
TBT. Butler
T. Butler
NRN.L. Rupesinghe
N.L. Rupesinghe
GAGehan Amaratunga
Gehan Amaratunga
SRS.J. Rashid
S.J. Rashid
Gheorghe BrezeanuGheorghe Brezeanu
Gheorghe Brezeanu

12 August 2025 in Polymers
Verified
Journal Article
Open access
PDF file
Bogdan ŞerbanBogdan Şerban
Bogdan Şerban
Octavian BuiuOctavian Buiu
Octavian Buiu
MBMarius Bumbac
Marius Bumbac
NDNiculae Dumbrăvescu
Niculae Dumbrăvescu
MBMihai Brezeanu
Mihai Brezeanu
Cornel CobianuCornel Cobianu
Cornel Cobianu
Carbon nanohorns (CNHs), along with their nanocomposites and nanohybrids, have shown significant potential for humidity (RH) monitoring at room temperature (RT) due to their exceptional physicochemical and electronic properties, such as high surface area, tunable porosity, and stability in nanocomposites. Resistive sensors incorporating CNHs have demonstrated superior sensitivity compared to traditional carbon nanomaterials, such as carbon nanotubes and graphene derivatives, particularly in specific RH ranges. This review highlights recent advancements in CNH-based resistive RH sensors, discussing effective synthesis methods (e.g., arc discharge and laser ablation) and functionalization strategies, such as the incorporation of hydrophilic polymers or inorganic fillers like graphene oxide (GO) and metal oxides, which enhance sensitivity and stability. The inclusion of fillers, guided by Pearson’s Hard–Soft Acid–Base (HSAB) theory, enables tuning of CNH-based sensing layers for optimal interaction with water molecules. CNH-based nanocomposites exhibit competitive response and recovery times, making them strong candidates for commercial sensor applications. However, challenges remain, such as optimizing materials for operation across the full 0–100% RH range. This review concludes with proposed research directions to further enhance the adoption and utility of CNHs in sensing applications.

20 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Bogdan ŞerbanBogdan Şerban
Bogdan Şerban
NDNiculae Dumbravescu
Niculae Dumbravescu
Octavian BuiuOctavian Buiu
Octavian Buiu
MBMarius Bumbac
Marius Bumbac
MBMihai Brezeanu
Mihai Brezeanu
Cornel CobianuCornel Cobianu
Cornel Cobianu
The study presents the ethanol vapor sensing performance of a resistive sensor that utilizes a quaternary nanohybrid sensing layer composed of holey carbon nanohorns (CNHox), graphene oxide (GO), SnO2, and polyvinylpyrrolidone (PVP) in an equal mass ratio of 1:1:1:1 (w/w/w/w). The sensing device includes a flexible polyimide substrate and interdigital transducer (IDT)-like electrodes. The sensing film is deposited by drop-casting on the sensing structure. The morphology and composition of the sensitive film are analyzed using scanning electron microscopy (SEM), Energy Dispersive X-ray (EDX) Spectroscopy, and Raman spectroscopy. The manufactured resistive device presents good sensitivity to concentrations of alcohol vapors varying in the range of 0.008–0.16 mg/cm3. The resistance of the proposed sensing structure increases over the entire range of measured ethanol concentration. Different types of sensing mechanisms are recognized. The decrease in the hole concentration in CNHox, GO, and CNHox due to the interaction with ethanol vapors, which act as electron donors, and the swelling of the PVP are plausible and seem to be the prevalent sensing pathway. The hard–soft acid-base (HSAB) principle strengthens our analysis.

30 July 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Bogdan ŞerbanBogdan Şerban
Bogdan Şerban
Octavian BuiuOctavian Buiu
Octavian Buiu
MBMarius Bumbac
Marius Bumbac
MBMihai Brezeanu
Mihai Brezeanu
MMMaria-Roxana Marinescu
Maria-Roxana Marinescu
VDVlad Diaconescu
Vlad Diaconescu
In recent years, carbon nano-onions (CNOs), together with their functionalized derivatives, nanocomposites, and nanohybrids, have attracted increasing attention as sensing materials for monitoring relative humidity (RH), gases, and temperature. Their concentric graphitic structure provides good electrical conductivity, chemical and thermal stability, accessible surface sites, tunable surface chemistry, and compatibility with polymer matrices and flexible substrates. This review highlights recent advances in the synthesis and functionalization of CNOs and examines their integration into chemiresistive, surface acoustic wave, flexible, and printed sensing platforms. Particular attention is devoted to pristine and oxidized CNOs, heteroatom-doped materials, and composites incorporating hydrophilic or conducting polymers, metal oxides, and other functional fillers. CNOs-based sensing layers demonstrate room-temperature (RT) detection of RH, hydrogen, ammonia, acetone, ethanol, isopropanol, carbon dioxide, hydrogen sulfide, and other volatile organic compounds. In addition, CNOs and CNOs–polymer films exhibit significant temperature-dependent variations in resistance, supporting their potential use in flexible and wearable temperature sensors. Although several CNOs-based devices show superior performance in sensitivity, response, recovery characteristics, mechanical flexibility, and low-power operation, the studies on CNOs available in the literature remain limited compared with those on carbon nanotubes, graphene derivatives, and other carbonaceous materials. Further progress on CNOs-based structures requires reproducible, large-scale synthesis; improved film uniformity and selectivity; standardized testing; compensation for temperature–humidity cross-sensitivity; and long-term stability studies. This review concludes by highlighting research directions to bridge the gap between laboratory prototypes and commercially viable CNOs-based sensing devices.

30 July 1991 in ChemInform
Verified
Journal Article
Closed access
PDF file
PSP. Spacu
P. Spacu
MBMihai Brezeanu
Mihai Brezeanu
LPL. Patron
L. Patron
ACA. Contescu
A. Contescu
DCD. Crisan
D. Crisan
ESEvelyne Ségal-bendirdjian
Evelyne Ségal-bendirdjian