This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard requirements.
6 December 2007 in IEEE Transactions on Instrumentation and Measurement
Power quality instrumentation requires accurate fundamental frequency estimation and signal synchronization, even in the presence of both stationary and transient disturbances. In this paper, the authors present a synchronization technique for power quality instruments based on a single-phase software phase-locked loop (PLL), which is able to perform the synchronization, even in the presence of such disturbances. Moreover, PLL is able to detect the occurrence of a transient disturbance. To evaluate if and how the synchronization technique is adversely affected by the application of stationary and transient disturbing influences, appropriate testing conditions have been developed, taking into account the requirements of the in-force standards and the presence of the voltage transducer.
2 November 2023 in Renewable and Sustainable Energy Reviews
Grid-connected photovoltaic systems are increasingly used in electrical distribution systems. However, they inject distorted currents. Therefore, special attention must be paid to harmonic and interharmonic measurements. The new edition of IEC 61000-4-7 introduces the concept of harmonic and interharmonic groups, which implies new expressions for total harmonic distortion (THD) factors. In this paper, a theoretical and experimental comparison is made between the different THD factors in order to show which of the currently defined distortion factors is best suited to detect harmonic and interharmonic pollution. Experimental tests were carried out first by means of a calibrator and subsequently in a single-phase grid-connected photovoltaic system. In both cases, measurements were carried out with a PC-based instrument developed by the authors and able to calculate the distortion factors according to IEC 61000-4-7.
13 December 2018 in IEEE Transactions on Instrumentation and Measurement
The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the evaluation of CT performance under distorted waveform conditions is not a reliable method.