Antonio Cataliotti

Prof. Antonio Cataliotti

Department of Engineering, Università degli studi di Palermo, Viale delle Scienze, 90128 Palermo, Italy
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GAGiovanni Artale
Giovanni Artale
ACAntonio Cataliotti
Antonio Cataliotti
VCValentina Cosentino
Valentina Cosentino
Dario Di CaraDario Di Cara
Dario Di Cara
SNSalvatore Nuccio
Salvatore Nuccio
GTGIOVANNI TINE'
GIOVANNI TINE'
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard requirements.

6 December 2007 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ACAntonio Cataliotti
Antonio Cataliotti
VCValentina Cosentino
Valentina Cosentino
SNSalvatore Nuccio
Salvatore Nuccio
Power quality instrumentation requires accurate fundamental frequency estimation and signal synchronization, even in the presence of both stationary and transient disturbances. In this paper, the authors present a synchronization technique for power quality instruments based on a single-phase software phase-locked loop (PLL), which is able to perform the synchronization, even in the presence of such disturbances. Moreover, PLL is able to detect the occurrence of a transient disturbance. To evaluate if and how the synchronization technique is adversely affected by the application of stationary and transient disturbing influences, appropriate testing conditions have been developed, taking into account the requirements of the in-force standards and the presence of the voltage transducer.

2 November 2023 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
VBValeria Boscaino
Valeria Boscaino
VDVito Ditta
Vito Ditta
GMGiuseppe Marsala
Giuseppe Marsala
PNPanzavecchia Nicola
Panzavecchia Nicola
GTGIOVANNI TINE'
GIOVANNI TINE'
Dario Di CaraDario Di Cara
Dario Di Cara

26 June 2006 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MAM. Aiello
M. Aiello
ACAntonio Cataliotti
Antonio Cataliotti
SFSalvatore Favuzza
Salvatore Favuzza
GGG. Graditi
G. Graditi
Grid-connected photovoltaic systems are increasingly used in electrical distribution systems. However, they inject distorted currents. Therefore, special attention must be paid to harmonic and interharmonic measurements. The new edition of IEC 61000-4-7 introduces the concept of harmonic and interharmonic groups, which implies new expressions for total harmonic distortion (THD) factors. In this paper, a theoretical and experimental comparison is made between the different THD factors in order to show which of the currently defined distortion factors is best suited to detect harmonic and interharmonic pollution. Experimental tests were carried out first by means of a calibrator and subsequently in a single-phase grid-connected photovoltaic system. In both cases, measurements were carried out with a PC-based instrument developed by the authors and able to calculate the distortion factors according to IEC 61000-4-7.

13 December 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ACAntonio Cataliotti
Antonio Cataliotti
VCValentina Cosentino
Valentina Cosentino
GCGabriella Crotti
Gabriella Crotti
AFAntonio Delle Femine
Antonio Delle Femine
Dario Di CaraDario Di Cara
Dario Di Cara
GTGIOVANNI TINE'
GIOVANNI TINE'

13 January 2009 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ACAntonio Cataliotti
Antonio Cataliotti
Dario Di CaraDario Di Cara
Dario Di Cara
AEAlexander E. Emanuel
Alexander E. Emanuel
SNSalvatore Nuccio
Salvatore Nuccio
The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the evaluation of CT performance under distorted waveform conditions is not a reliable method.