11 January 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GAGiovanni Artale
Giovanni Artale
ACAntonio Cataliotti
Antonio Cataliotti
VCValentina Cosentino
Valentina Cosentino
Dario Di CaraDario Di Cara
Dario Di Cara
SNSalvatore Nuccio
Salvatore Nuccio
GTGIOVANNI TINE'
GIOVANNI TINE'
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard requirements.

4 April 2008 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Maria Carmela Di PiazzaMaria Carmela Di Piazza
Maria Carmela Di Piazza
GTGIOVANNI TINE'
GIOVANNI TINE'
Gianpaolo VitaleGianpaolo Vitale
Gianpaolo Vitale
This paper presents a new device for the compensation of common-mode (CM) disturbance in induction motor drives, based on the active cancellation approach. The detailed design and the experimental implementation issues of the new active compensation device for a 380-V/50-Hz pulsewidth-modulation (PWM) induction motor drive are discussed. Starting from the idea of the active common-noise canceller, the proposed active compensation device is suitably improved in order to overcome the limitations of similar previously proposed circuits. In fact, it can be successfully used within a drive system with a rated voltage of 380 V or higher by employing an improved active circuit with a dedicated dc power supply derived from the ac power supply line. In addition, the design follows the criteria of compactness and minimum cost. The performance of the realized active compensation device is verified through experimental measurements of the CM voltage, the CM current, and the motor shaft voltage. The effectiveness of the proposed solution is demonstrated by experimental results.

2 November 2023 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
VBValeria Boscaino
Valeria Boscaino
VDVito Ditta
Vito Ditta
GMGiuseppe Marsala
Giuseppe Marsala
PNPanzavecchia Nicola
Panzavecchia Nicola
GTGIOVANNI TINE'
GIOVANNI TINE'
Dario Di CaraDario Di Cara
Dario Di Cara

13 December 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ACAntonio Cataliotti
Antonio Cataliotti
VCValentina Cosentino
Valentina Cosentino
GCGabriella Crotti
Gabriella Crotti
AFAntonio Delle Femine
Antonio Delle Femine
Dario Di CaraDario Di Cara
Dario Di Cara
GTGIOVANNI TINE'
GIOVANNI TINE'

31 March 2008 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ACAntonio Cataliotti
Antonio Cataliotti
ADAlfredo Daidone
Alfredo Daidone
GTGIOVANNI TINE'
GIOVANNI TINE'
The aim of this paper is to illustrate the development of a theoretical and experimental study on the characterization of medium voltage (MV) cables in the frequency range 25-200 kHz. Two transmission line configurations, line-ground and line-line, were considered in order to evaluate the main parameters, such as the characteristic impedance and the attenuation constant alpha. A simplified model of the line-ground configuration is proposed which allows one to evaluate the characteristic impedance and the attenuation constant by means of geometrical dimensions. The model was verified by experimental measurements on commonly used MV cables, RG7H1R, with an aluminium core of different sections, 95 mm2 and 185 mm2. Moreover, the experimental tests were carried out for the line-line configuration.

6 November 2015 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ACAntonio Cataliotti
Antonio Cataliotti
VCValentina Cosentino
Valentina Cosentino
Dario Di CaraDario Di Cara
Dario Di Cara
GTGIOVANNI TINE'
GIOVANNI TINE'
This paper deals with the issue of measurement device placement for load flow analysis in medium-voltage (MV) distribution networks. The study is carried out using an innovative measurement algorithm for load flow analysis developed by the authors. It is based on low-voltage (LV) load power measurements applied on a backward/forward algorithm for the load flow resolution. The final aim is to identify the most suitable number and placement of the LV measurement points in order to limit the uncertainty on the power flow estimation to a target value. The proposed approach is based on the uncertainty evaluation of the estimated power flows; a sensitivity analysis is performed in order to assess the uncertainty contribution of each LV power measurement to the estimated power flow upstream of each MV feeder of the distribution network. The LV measurement device placement is presented and discussed in a real case study, i.e., the distribution network of the Ustica Island.