Gabriella Crotti

Dr. Gabriella Crotti


Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ACAntonio Cataliotti
Antonio Cataliotti
VCValentina Cosentino
Valentina Cosentino
GCGabriella Crotti
Gabriella Crotti
AFAntonio Delle Femine
Antonio Delle Femine
Dario Di CaraDario Di Cara
Dario Di Cara
GTGIOVANNI TINE'
GIOVANNI TINE'

24 September 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
GCGabriella Crotti
Gabriella Crotti
Giovanni D'AvanzoGiovanni D'Avanzo
Giovanni D'Avanzo
PLPalma Sara Letizia
Palma Sara Letizia
MLMario Luiso
Mario Luiso
The measurement of harmonics is one of the key tasks in modern power systems, performed basically for power quality assessment, verification of planning levels compliance, immunity and compatibility purposes, and so on. Especially at medium voltage (MV) and high voltage (HV) levels, harmonics are always measured through voltage and current transformers (VTs and CTs), which very often are inductive. Recent articles show that inductive VTs and CTs, due to the intrinsic iron core nonlinearity, can introduce errors up to some percent in harmonic measurements. This article aims to investigate in-depth this phenomenon by analyzing how the accuracy of harmonic measurements performed through an inductive MV VT is affected by the presence subharmonics in its input voltage. Subharmonics are spectral components having frequencies lower than the power frequency, that is 50 Hz for European countries. Some theoretical considerations are carried out and the performances of two different inductive MV VTs are tested in various operating conditions. Experimental results show that subharmonics can worsen the harmonic measurements done through inductive VTs up to some tens of percent.

2 October 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Marco FaiferMarco Faifer
Marco Faifer
Christian LauranoChristian Laurano
Christian Laurano
Roberto OttoboniRoberto Ottoboni
Roberto Ottoboni
Sergio ToscaniSergio Toscani
Sergio Toscani
Michele ZanoniMichele Zanoni
Michele Zanoni
PMPaolo Mazza
Paolo Mazza
The most recent IEC standards about voltage transformers warn about nonlinearity, which may significantly impact the harmonic measurement performance. However, there is a lack of scientific literature about this topic: usually their characterization consists of frequency response measurements that are clearly not able to capture the nonlinear behavior. In this paper, an innovative approach based on recently developed simplified frequency-domain polynomial models is proposed. The method is applied to two different medium-voltage inductive transformers. Models are identified and validated with a large set of realistic primary waveforms injected by a proper setup. Experimental results confirm the remarkable accuracy of the proposed models especially for low-order harmonics, which are the most affected by nonlinearity.

16 April 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
GCGabriella Crotti
Gabriella Crotti
AFAntonio Delle Femine
Antonio Delle Femine
Daniele GalloDaniele Gallo
Daniele Gallo
DGDomenico Giordano
Domenico Giordano
Carmine LandiCarmine Landi
Carmine Landi
PRPaolo Emilio Roccato
Paolo Emilio Roccato

4 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
GCGabriella Crotti
Gabriella Crotti
YCYeying Chen
Yeying Chen
HÇHuseyin Çayci
Huseyin Çayci
Giovanni D'AvanzoGiovanni D'Avanzo
Giovanni D'Avanzo
Carmine LandiCarmine Landi
Carmine Landi
HBHelko van den Brom
Helko van den Brom
The integration of renewable energy sources on a large scale in the electrical energy distribution systems, as well as the widespread of non-linear loads, has led to a significant increase in power quality (PQ) disturbances. For this reason, PQ monitoring is also becoming a key task in medium voltage (MV) grids. The measurement of PQ at MV levels can only be performed using instrument transformers (ITs) to scale down the level of voltage and current to levels suitable for the input stage of PQ instruments. However, no international standards currently require the verification of the errors introduced by ITs in the measurement of PQ phenomena. Moreover, this issue is only partially addressed in the scientific literature, where papers dealing with specific and limited aspects of the problem can be found. For this reason, this paper aims to comprehensively assess the issue, proposing IT accuracy verification tests for different PQ parameters. First, a set of PQ phenomena relevant for IT testing is chosen, as well as the associated ranges of variation, based on a review of the enforced standards and the scientific literature. For each selected PQ phenomenon, possible performance indices and test waveforms are proposed. Finally, the proposed procedure is validated by applying it to the characterization of two different types of commercial voltage transformers.

12 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
PLPalma Sara Letizia
Palma Sara Letizia
GCGabriella Crotti
Gabriella Crotti
Alessandro MingottiAlessandro Mingotti
Alessandro Mingotti
ROBERTO TINARELLIROBERTO TINARELLI
ROBERTO TINARELLI
YCYeying Chen
Yeying Chen
RSRobert Stiegler
Robert Stiegler
Instrument transformers (ITs) play a key role in electrical power systems, facilitating the accurate monitoring and measurement of electrical quantities. They are essential for measurement, protection, and metering in transmission and distribution grids and accurately reducing the grid voltage and current for low-voltage input instrumentation. With the increase in renewable energy sources, electronic converters, and electric vehicles connected to power grids, ITs now face challenging distorted conditions that differ from the nominal ones. The study presented in this paper is a collaborative work between national metrology institutes and universities that analyzes IT performance in measuring distorted voltages and currents in medium-voltage grids under realistic conditions. Both current and voltage measuring transformers are examined, considering influence quantities like the temperature, mechanical vibration, burden, adjacent phases, and proximity effects. The study provides detailed insights into measurement setups and procedures, and it quantifies potential errors arising from IT behavior in measuring distorted signals in the presence of the various considered influence quantities and their combinations. The main findings reveal that the temperature has the most evident impact on the inductive voltage transformer performance, as well as the burden, causing significant changes in ratio error and phase displacement at the lower temperatures. As for low-power ITs, establishing a priori the effects of adjacent phases and proximity on the frequency responses of low-power ITs is a complex matter, because of their different characteristics and construction solutions.