Rammed earth (RE) is a low-tech recyclable building material with good heat storage and moisture absorption performance that can better maintain the stability of the indoor thermal environment and improve indoor comfort. With innovations in and the development of new technology, the field of rammed earth construction technology is gradually expanding. However, deficiencies in the thermal insulation of traditional rammed earth structures make it impossible for them to meet China’s building energy codes in cold regions. This study constructs a comprehensive evaluation index of the thermal performance of rammed earth walls that is based on the heat transfer mechanism, optimizing the thickness of the boundary conditions of the building interior’s design temperature, as well as the energy demand and economic efficiency. This research also offers a new design for the thermal insulation of rammed earth construction by combining the building energy savings design code with WUFI Pro software. This study demonstrates that the optimum thickness of rammed earth construction in Beijing is about 360 mm, the thickness of extruded polystyrene board (XPS) is 50 mm (for public buildings) and 70 mm (for residential buildings), and the structural form of external insulation offers the highest performance benefit. In addition, this work also evaluates the risk of condensation inside composite rammed earth construction, finding that there is a risk of condensation on the exterior side of the wall and at the interface between the insulation panels and rammed earth wall, thus requiring an additional moisture-proof layer. In this study, thermal mass and insulation are fully considered and a design strategy for rammed earth construction given quantitatively, providing a theoretical basis for the application of rammed earth materials in cold regions.
Reflective materials, characterized by high albedo and thermal emissivity, offer effective passive cooling strategies for reducing building energy demand. While prior studies have developed thermal transfer models validated under laboratory conditions or conducted short-term monitoring in non-air-conditioned spaces, their effectiveness in operational buildings remains underexplored. This research evaluates the change in cooling energy demand and indoor thermal comfort in a retrofitted office building with reflective materials in China’s Hot Summer and Cold Winter (HSCW) zone. The calibrated WUFI®Plus simulations show that the application of reflective roof and window materials can result in an 11.3% reduction in cooling energy demand. Moreover, occupant surveys indicate improved thermal perception, with the mean Thermal Comfort Vote (TCV) rising from −0.75 to −0.30, thermal acceptability increasing from 0.10 to 0.35, and 80% of occupants reporting cooler conditions. These subjective results align with simulated Predicted Mean Vote (PMV) reductions (0.82 → 0.74), confirming the retrofit’s effectiveness. While the energy savings are more modest than those reported in Mediterranean climates, they are generally consistent with the energy saving ratios of buildings in the HSCW region as evaluated by previous studies. This study provides a framework for assessing retrofits in occupied buildings with reflective materials and indicates the practicality of such retrofits as an economic, low-disruption strategy for upgrading aging office building stocks in the HSCW zone.