Daniel Nißler

Dr. Daniel Nißler

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DNDaniel Nißler
Daniel Nißler
SRSabrina Reimers-Kipping
Sabrina Reimers-Kipping
MIMaja Ingwersen
Maja Ingwersen
FBFrank Berger
Frank Berger
FNFelix Niekrenz
Felix Niekrenz
TFTobias Franiel
Tobias Franiel
Objectives: To evaluate the diagnostic accuracy of AI-assisted biparametric MRI (AI-bpMRI) in detecting prostate cancer (PCa) as a possible replacement for multiparametric MRI (mpMRI) depending on readers’ experience. Methods: This fully crossed, multireader multicase, single-centre, consecutive study retrospectively included men with suspected PCa. Three radiologists with different levels of experience independently scored each participant’s biparametric (bp) MRI, mpMRI, and AI-bpMRI according to the PI-RADS V2.1 classification. The AI-assisted image processing was based on a sequential deep learning network. Histopathological findings were used as a reference. The study evaluated the mean areas under the receiver operating characteristic curves (AUCs) using the jackknife method for covariance. AUCs were tested for non-inferiority of AI-bpMRI to mpMRI (non-inferiority margin: −0.05). Results: A total of 105 men (mean age 66 ± 7 years) were evaluated. AI-bpMRI was non-inferior to mpMRI in detecting both Gleason score (GS) ≥ 3 + 4 PCa (AUC difference: 0.03 [95% CI: −0.03, 0.08], p = 0.37) and GS ≥ 3 + 3 PCa (AUC difference: 0.04 [95% CI: −0.01, 0.09], p = 0.14) and was superior to bpMRI in detecting GS ≥ 3 + 3 PCa (AUC difference: 0.07 [95% CI: 0.02, 0.12], p = 0.004). The benefit of AI-bpMRI was greatest for the readers with low or medium experience (AUC difference in detecting GS ≥ 3 + 4 compared to mpMRI: 0.06 [95% CI: −0.03, 0.14], p = 0.19 and 0.06 [95% CI: −0.03, 0.14], p = 0.19, respectively). Conclusions: This study indicates that AI-bpMRI detects PCa with a diagnostic accuracy comparable to that of mpMRI.

1 March 2026 in Radiology
Verified
Journal Article
Closed access
Christian KühnelChristian Kühnel
Christian Kühnel
TSTabea Nikola Schmidt
Tabea Nikola Schmidt
MFMartin Freesmeyer
Martin Freesmeyer
MSMiriam Schricke
Miriam Schricke
LSLeonie Schreiber
Leonie Schreiber
PSPhilipp Seifert
Philipp Seifert
Transarterial radioembolization generally results in low radiation exposure for medical staff; 166 Ho-poly-L-lactic acid microspheres led to the highest body doses, while 90 Y-resin microspheres generated the highest hand doses, with interventional radiologists receiving the highest overall doses.