Dipole magnet vacuum chambers are among the most critical and costly components of rapid-cycling accelerator facilities. Alternative approaches to traditional ceramic chambers have been explored for the implementation of fast-ramping dipole-magnet vacuum chambers, including thin-wall metallic beam pipe chambers strengthened with transverse ribs and ceramic rings inside thin-walled chambers. Here, we report a novel 3D-printed titanium alloy cage inside the thin-wall vacuum chamber, which is designed for high-intensity heavy ion accelerator facility (HIAF) to reduce manufacturing difficulty and cost, shorten the production cycle, and improve the quality. Comprehensive studies were undertaken to characterize the impedance of the 3D-printed titanium alloy cage inside the thin-wall vacuum chamber. The beam-coupling impedance and eddy currents of the new thin-wall vacuum chamber were studied mostly numerically. Strategies for further reducing the beam-coupling impedance were explored. In addition, impedance bench measurements using the “half wavelength” resonant method were conducted to identify the longitudinal and transverse impedances of the 3D-printed titanium alloy cage inside the thin-wall vacuum chamber prototype experimentally. The simulated and measured results for the impedance were consistent. Furthermore, a campaign for resonance-check measurements on the 3D-printed titanium alloy ring loaded inside a thin-wall vacuum chamber prototype was launched. This novel thin-wall vacuum chamber structure is now entering the fabrication stage and will soon be ready for installation in the Booster Ring (BRing).
19 February 2021 in Nuclear Science and Techniques
Stochastic cooling of the Spectrometer Ring (SRing) at the High Intensity heavy-ion Accelerator Facility (HIAF) project in China, which is used mainly for experiments with radioactive fragment beams, is applied to speed up the cooling process of a stored ion beam. In this study, both a Faltin traveling wave structure and a novel slot-ring standing wave structure based on a ceramic vacuum chamber are discussed and evaluated for the pickup/kicker of the SRing stochastic cooling system. The slot-ring structure should significantly improve the shunt impedance due to the Cherenkov effect. For the Faltin-type structure, the results for the pickup shunt impedance obtained from simulations and from beam measurements agree well. Good agreement is also found between the simulated and measured results for the pickup shunt impedance of the slot-ring structure. Cooling process simulations using the Fokker – Planck equation based on the shunt impedance results for the Faltin and slot-ring type pickups are also presented.
20 May 2020 in IEEE Transactions on Nuclear Science
Due to high ramping rates on the Booster Ring (BRing), which is the key part of the HIAF (High Intensity heavy ion Accelerator Facility) complex at the Institute of Modern Physics (IMP), thin-wall vacuum chambers are required for all magnets to maintain the eddy currents at a tolerable level. A novel thin-wall vacuum chamber supported by ceramic rings was discussed and evaluated for the HIAF at the IMP to reduce the cost of manufacture process, reduce the difficulty, shorten the production cycle, and improve the quality. Because the beam coupling impedance aspects are highly important for beam stability, several approaches were used to evaluate the impedance on the ceramics loaded tube. In this paper, we describe the results from the single- and two-wire bench measurements and the numerical simulations. The simulated and measured impedance results are consistent with each other. Several effective methods to mitigate the impedance were proposed and investigated in detail. According to the simulation and measurement results of the beam coupling impedance mitigation, this novel ceramic rings copper coated thin-wall vacuum chamber structure will be considered for application to the HIAF project with the highest priority.
A new digital beam position and phase measurement (BPM) system was designed for the ion-Linac accelerator at the high intensity heavy ion accelerator facility. The fundamental and second harmonic signals are retrieved from the BPM electrodes to simultaneously calculate their respective beam positions and phases. All data acquisition and digital signal processing algorithm routines are performed in a field programmable gate array (FPGA). The position and phase information are obtained by using the in-phase and quadrature demodulation method. A practical and straightforward method is used to generate the second harmonic reference signal for processing the second harmonic beam signal. The reconfigurable filters are integrated into the FPGA to allow the measurement of short beam pulse length. The laboratory test results show that the achieved phase resolution is better than 0.2° and 0.03° when the input signal is −60 and −45 dBm, respectively. A position resolution better than 30 μm was achieved for an input power level of approximately −60 dBm, and it can reach 7 μm with the input power higher than −45 dBm. The entire execution time of the algorithm is accomplished within 3.4 µs, which provides a sufficient reaction time for the fast beam interlock signal to the machine protection system. The performance of this newly designed prototype BPM electronics was evaluated with the online proton beam.