The preparation of autologous platelet and extracellular vesicle-rich plasma (PVRP) has been explored in many medical fields with the aim to benefit from its healing potential. In parallel, efforts are being invested to understand the function and dynamics of PVRP that is complex in its composition and interactions. Some clinical evidence reveals beneficial effects of PVRP, while some report that there were no effects. To optimize the preparation methods, functions and mechanisms of PVRP, its constituents should be better understood. With the intention to promote further studies of autologous therapeutic PVRP, we performed a review on some topics regarding PVRP composition, harvesting, assessment and preservation, and also on clinical experience following PVRP application in humans and animals. Besides the acknowledged actions of platelets, leukocytes and different molecules, we focus on extracellular vesicles that were found abundant in PVRP.

16 September 2025 in Coatings
Verified
Journal Article
Open access
PDF file
BKBoštjan Kocjančič
Boštjan Kocjančič
EKEma Kocjančič
Ema Kocjančič
ŠKŠpela Tadel Kocjančič
Špela Tadel Kocjančič
JKJanez Kovač
Janez Kovač
Monika JenkoMonika Jenko
Monika Jenko
MDMojca Debeljak
Mojca Debeljak
Total hip arthroplasty (THA) is a widely performed and successful surgical treatment for degenerative joint disease. With increasing use in younger and more active patients, the demand for durable, biocompatible, and low-wear implant materials has grown. Oxidized zirconium (Oxinium, Zr2.5Nb) was introduced as a promising femoral head material, combining the strength of metal with the low-friction properties of ceramic. Despite encouraging early results, clinical reports have documented complications including head wear, especially after dislocation, and metallosis. We present the case of a 64-year-old male who underwent primary THA in 2009 and required revision in 2021 due to severe metallosis. Notably, no dislocation was observed that could explain the damage to the Oxinium head. Surface and subsurface analyses using X-ray photoelectron spectroscopy (XPS) and micro-indentation hardness testing revealed wear and deformation inconsistent with Oxinium’s anticipated durability. These findings highlight the importance of the femoral head–polyethylene liner interface in implant longevity. Although Oxinium–XLPE articulations remain promising, risks such as damage to the femoral head, liner dislocation, impingement, and metallosis must be carefully considered. Surgical technique, liner placement, and locking mechanisms play critical roles in preventing failure. Further biomechanical and clinical studies are needed to optimize implant design and improve long-term outcomes.

19 December 2019 in Materiali in tehnologije
Verified
Journal Article
Closed access
BKBoštjan Kocjančič
Boštjan Kocjančič
ALA. Lapoša
A. Lapoša
DDD. Dolinar
D. Dolinar

6 August 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
BKBoštjan Kocjančič
Boštjan Kocjančič
EKEma Kocjančič
Ema Kocjančič
ŠKŠpela Tadel Kocjančič
Špela Tadel Kocjančič
JKJanez Kovač
Janez Kovač
Monika JenkoMonika Jenko
Monika Jenko
MDMojca Debeljak
Mojca Debeljak
The aim of our study was evaluation of the Oxinium Femoral Heads in Hip Endoprosthesis: Clinical Outcomes, Wear Characteristics, and Long-Term Performance. Orthopaedic patients suffering from joint pain due to arthritis or injury and total hip arthroplasty (THA) is a common and very successful surgical option. THA involves replacing the damaged femoral head and acetabulum with prosthetic components, typically composed of metal alloys, ceramics and polymers. As the procedure becomes more common in younger, active individuals, there is growing demand for durable, low-wear implant materials. Oxidized zirconium Zr2.5Nb alloy (Oxinium, Ox Zr) was introduced as a promising alternative, designed to combine the strength of metal with the low-friction properties of ceramic. Oxinium is created by thermal heat treatment of zirconium-niobium alloy, resulting in a 4–5 µm thick ceramic-like surface diffusion layer. Oxinium femoral heads were expected to reduce wear and extend implant longevity. However, clinical reports have revealed complications. Findings include wear deformation of the Oxinium head, polyethylene liner dislocation, and metallosis in surrounding tissue. These failures are frequently associated with dislocation or impingement between the metal acetabular cup and the femoral head. We report on the case of 64 years old male his primary THA was in 2009 and revision surgery in 2021 after severe metallosis. The surface and subsurface of Oxinium head was examined by surface analytical method XPS and micro-indentation hardness measurements. These observations challenge the initial claims regarding Oxinium’s durability and wear resistance. In certain patients, particularly those at risk of joint instability or dislocation, Oxinium components may lead to accelerated wear, severe metallosis, and reduced implant longevity. The interface between an Oxinium femoral head and a highly cross-linked polyethylene (HXLPE) liner is critical to the long-term success of total hip arthroplasty (THA), particularly in preventing dislocation and wear-related complications. The Oxinium–HXLPE interface shows promise, but more biomechanical and clinical data are needed to refine implant design and surgical protocols.