Yudhistira Yudhistira

Mr. Yudhistira Yudhistira

School of Electronics Engineering, Kyungpook National University, Daegu, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2022 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
YYYudhistira Yudhistira
Yudhistira Yudhistira
YYYoppy Yoppy
Yoppy Yoppy
ETElvina Trivida
Elvina Trivida
TWTyas Ari Wahyu Wijanarko
Tyas Ari Wahyu Wijanarko
HNHutomo Wahyu Nugroho
Hutomo Wahyu Nugroho
DMDwi Mandaris
Dwi Mandaris
The measurement and analysis of electromagnetic interference (EMI) from light rapid transit (LRT) axle counters against magnetic field interference in Indonesia has been carried out. The low-cost magnetic sensors were developed according to the British Standard (BS) EN 50592:2016. The measurement setup and magnetic field limit were based on the British Standard EN 50592:2016 and ERA/ERTMS/033281 standard. Two frequency range of the measurements, lower and higher frequencies with two different train running mode, acceleration mode and deceleration mode were applied in this research. The results in lower frequency range (10 to 100 kHz) were very close to the limit value in both acceleration and deceleration mode, especially at the 30 to 50 kHz for the y and z directions. Although there may possibly magnetic interference at low frequencies, most of the magnetic field emissions were still in acceptable range.

27 September 2021
Verified
Conference Paper
Closed access
YYYudhistira Yudhistira
Yudhistira Yudhistira
PBPrayoga Bakti
Prayoga Bakti
TWTyas Ari Wahyu Wijanarko
Tyas Ari Wahyu Wijanarko
DMDwi Mandaris
Dwi Mandaris
The phenomenon of harmonic current arising from an inverter connected to the load in an off-grid photovoltaic (PV) system has been identified. The pure sine wave (PSW) and modified sine wave (MSW) inverters were used in this study and were connected to the load of incandescent and LED lamps. The Power Analyzer was used to obtain the output voltage of each inverter and the current harmonic values in the inverter and load lines. The highest percentage value of harmonic current is 72.51 % for the PSW inverter connected to the LED lamp and 49.92% for the MSW inverter connected to the LED Lamp. Further research is needed regarding the filtering method to reduce the harmonic current so that the PSW and MSW inverter could be used properly in the off-grid PV system.

27 September 2021
Verified
Conference Paper
Closed access
YYYudhistira Yudhistira
Yudhistira Yudhistira
DMDwi Mandaris
Dwi Mandaris
YYYoppy Yoppy
Yoppy Yoppy
DHDeny Hamdani
Deny Hamdani
TRTri Desmana Rachmilda
Tri Desmana Rachmilda
FNFerdaus Ario Nurman
Ferdaus Ario Nurman
The comparison and analysis of conducted emission measurements on the off-grid photovoltaic (PV) inverter on the direct current (DC) side using two DC Line Impedance Stabilization Network (DC-LISN) models has been successfully carried out. The DC- LISN originating from the manufacturer was used as the first model while the self-developed model using more affordable materials was used as the second model. The impedance and isolation characteristic values of each DC-LISN are compared based on CISPR 16-1-2:2014. The results of impedance and isolation of each DC-LISN were within the tolerance range allowed by the standard. Furthermore, the measurement setup in the IEC 62920:2017 standard was applied to measure the conducted emission on the DC side of the PV inverter various in no-load mode. The highest level of noise was obtained with the 500 W inverter, both when using the first and second DC-LISN models. In addition, the difference of the maximum peak noise value of about 6 dB between the first and second DC-LISN models were due to the inductance value, 5 μH for the first DC-LISN and 50 μH for the second DC-LISN. The discrepancy of the peak noise profile at high frequency that occurs in all inverters were due to differences in the characteristics of DC-LISN components. However, the entire peak noise profile of the second DC-LISN model is utterly similar to the first model interprets that the low-cost, self-developed DC- LISN could be used as an alternative to conduct the conducted emission measurement of PV inverters.

7 July 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Mohamad AnamMohamad Anam
Mohamad Anam
YYYudhistira Yudhistira
Yudhistira Yudhistira
Sangjo ChoiSangjo Choi
Sangjo Choi
Thermoelectric nanoantennas have been extensively investigated due to their ability to directly convert infrared (IR) radiation into direct current without an additional rectification device. In this study, we introduce a thermoelectric nanoantenna geometry for maximum output voltage (Voc) and propose an optimal series array configuration with a finite number of antennas to enhance the Voc. A finite and open-ended SiO2 substrate, with a thickness of a quarter-effective wavelength at a frequency of 28.3 THz, is used to generate standing waves within the substrate. An array of antennas is then positioned optimally on the substrate to maximize the temperature difference (∆T) between hot and cold areas, thereby increasing the average Voc per antenna element. In numerical simulations, a linearly polarized incident wave with a power density of 1.42 W/cm2 is applied to the structure. The results show that a single antenna with the optimum geometry on a substrate measuring 35 µm × 35 µm generates a ∆T of 64.89 mK, corresponding to a Voc of 1.75 µV. Finally, a series array of 5 × 6 thermoelectric nanoantennas on a 150 µm × 75 µm substrate including measurement pads achieves an average ∆T of 49.60 mK with a total Voc of 40.18 µV, resulting in an average Voc of 1.34 µV per antenna element and a voltage responsivity (βv) of 0.77 V/W. This value, achieved solely by optimizing the antenna geometry and open-ended substrate, matches or exceeds the Voc and βv of approximately 1 µV and 0.66 V/W, respectively, from suspended thermoelectric antenna arrays over air cavities. Therefore, the proposed thermoelectric nanoantenna array device, characterized by high stability and ease of fabrication, is suitable for manufacturing massive nanoantenna arrays for high-output IR-DC energy harvesters.

1 February 2024 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
YYYoppy Yoppy
Yoppy Yoppy
YYYudhistira Yudhistira
Yudhistira Yudhistira
HNHutomo Wahyu Nugroho
Hutomo Wahyu Nugroho
ETElvina Trivida
Elvina Trivida
TWTyas Ari Wahyu Wijanarko
Tyas Ari Wahyu Wijanarko
DMDwi Mandaris
Dwi Mandaris
Measurement of magnetic fields near the railway tracks is crucial to ensure compatibility with the operation of axle counters. According to EN 50592 standard, the magnetic field is detected with a passive magnetic coil and an oscilloscope. From previous studies, in general, there has been no in-depth analysis of how the choice of coil winding parameters could affect the coil output voltage, which then affect the measurement sensitivity, in particular the coil design based on the standard and it is applicability for electromagnetic interference (EMI) evaluation of axle counters. Therefore, this paper will explore the design of a passive magnetic coil to obtain the optimum coil output voltage within the frequency range. Simulations showed that for 10-100 kHz and 100 kHz–1.3 MHz range, the optimum number of turns happened at 60-100 and 15-60 turns, respectively. Based on that, two example coils had been built. Simulations and measurements of their frequency response were in good agreement, with a deviation less than 1.0 dB.

1 July 2016 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
YYYoppy Yoppy
Yoppy Yoppy
Mohamad AnamMohamad Anam
Mohamad Anam
YYYudhistira Yudhistira
Yudhistira Yudhistira
PWPriyo Wibowo
Priyo Wibowo
HAHarry Arjadi
Harry Arjadi
HPHaryo Dwi Prananto
Haryo Dwi Prananto
Pulsed electric fields (PEF) is a novel non-thermal food processing whose purpose is inactivating microbes while at the same time preserving food’s nutrition, color, and taste. This paper presents an analysis of step up transormer for PEF high voltage generator. To achieve the optimum PEF effects, the pulse shape should resemble a square, which is characterized by low voltage drop and fast rising time. Through simulations, it has been shown that higher transformer inductance results in lower voltage drop. However at some points, further increasing the inductance would only produces negligible improvements. Meanwhile fast rising time can be achieved by minimizing leakage inductance and parasitic capacitance. Moreover, maximum energy transfer to the load can be obtained by reducing winding resistances. Finally, a case of high voltage generator using ignition coil has been evaluated. Due to its high winding resistances, ignition coil seems to be not suitable for PEF applications.