Bong Kuk Lee

Dr. Bong Kuk Lee


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2012 in Journal of Materials Chemistry
Verified
Journal Article
Closed access
PDF file
BLBong Kuk Lee
Bong Kuk Lee
KPKun-Sik Park
Kun-Sik Park
DKDong-Pyo Kim
Dong-Pyo Kim
JRJin-Hwa Ryu
Jin-Hwa Ryu
JPJaehoon Park
Jaehoon Park
LDLee-Mi Do
Lee-Mi Do
A material approach to fabricating high-performance nonstick molds for manufacturing ultrahigh-resolution features (92% at 365 nm), high modulus and wide-range modulus tunability (0.757–4.192 GPa), high resistance to organic solvents (<1.2 wt%), low shrinkage (<3%), and high water contact angle (91–103°). The Si-SSQA–acrylic blends with a nonstick property were easily transferred to high-resolution replica molds with sub-25 nm features, a pitch of 25 nm and a height of 100 nm, even if the release agent was not modified onto the master. In addition, nonstick replica molds with a low concentration of uncross-linked (meth)acrylate showed the ability to duplicate ultrasmall nanostructures with a sub-8 nm parallel line, a pitch of 17 nm and a height of 6–7 nm. Furthermore, the Si-SSQA-based replica mold prevented the formation of bubble defects during imprinting owing to sufficient gas permeability.

1 October 2014 in ETRI Journal
Verified
Journal Article
Open access
PDF file
JRJin Hwa Ryu
Jin Hwa Ryu
WLWoo-Jin Lee
Woo-Jin Lee
BLBong Kuk Lee
Bong Kuk Lee
LDLee-Mi Do
Lee-Mi Do
KLKang Bok Lee
Kang Bok Lee
KBKyu-Ha Baek
Kyu-Ha Baek
This study proposes a novel optical sensor structure based on a refractometer combining a bend waveguide with an air trench. The optical sensor is a 12 splitter structure with a reference channel and a sensing channel. The reference channel has a straight waveguide. The sensing channel consists of a U-bend waveguide connecting four C-bends, and a trench structure to partially expose the core layer. The U-bend waveguide consists of one C-bend with the maximum optical loss and three C-bends with minimum losses. A trench provides a quantitative measurement environment and is aligned with the sidewall of the C-bend having the maximum loss. The intensity of the output power depends on the change in the refractive index of the measured material. The insertion loss of the proposed optical sensor changes from 3.7 dB to 59.1 dB when the refractive index changes from 1.3852 to 1.4452.

18 April 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JRJin Hwa Ryu
Jin Hwa Ryu
SBSangwon Byun
Sangwon Byun
BLBong Kuk Lee
Bong Kuk Lee
BLBong Kuk Lee
Bong Kuk Lee
WJWon Ick Jang
Won Ick Jang
HYHan Young Yu
Han Young Yu
This study proposes a simple method of fabricating flexible electronic devices using a metal template for passive alignment between chip components and an interconnect layer, which enabled efficient alignment with high accuracy. An electrocardiogram (ECG) sensor was fabricated using 20 µm thick polyimide (PI) film as a flexible substrate to demonstrate the feasibility of the proposed method. The interconnect layer was fabricated by a two-step photolithography process and evaporation. After applying solder paste, the metal template was placed on top of the interconnect layer. The metal template had rectangular holes at the same position as the chip components on the interconnect layer. Rectangular hole sizes were designed to account for alignment tolerance of the chips. Passive alignment was performed by simply inserting the components in the holes of the template, which resulted in accurate alignment with positional tolerance of less than 10 µm based on the structural design, suggesting that our method can efficiently perform chip mounting with precision. Furthermore, a fabricated flexible ECG sensor was easily attachable to the curved skin surface and able to measure ECG signals from a human subject. These results suggest that the proposed method can be used to fabricate epidermal sensors, which are mounted on the skin to measure various physiological signals.

1 March 2016 in Journal of Nanoscience and Nanotechnology
Verified
Journal Article
Closed access
BLBong Kuk Lee
Bong Kuk Lee
HYHan Young Yu
Han Young Yu
YKYarkyeon Kim
Yarkyeon Kim
YYYong Sun Yoon
Yong Sun Yoon
WJWon Ik Jang
Won Ik Jang
JPJaehoon Park
Jaehoon Park
We report the fabrication of flexible replica molds for transfer printing of Ag ink on a rigid glass substrate. As mold precursors, acrylic mixtures were prepared from silsesquioxane-based materials, silicone acrylate, poly(propylene glycol) diacrylate, 3,3,4,4,5,5,6,6,7,7,8,8, 9,9,10,10,10-heptadecafluorodecyl methacrylate, and photoinitiator. By using these materials, the replica molds were fabricated from a silicon master onto a flexible substrate by means of UV-assisted molding process at room temperature. The wettability of Ag ink decreased with increase in the water contact angle of replica molds. On the other hand, the transfer rate of Ag ink onto adhesive-modified substrates increased with increase in the water contact angle of replica molds. Transferred patterns were found to be thermally stable on the photocurable adhesive layer, whereas Ag-ink patterns transferred on non-photocurable adhesives were distorted by thermal treatment. We believe that these characteristics of replica molds and adhesives offer a new strategy for the development of the transfer printing of solution-based ink materials.

1 August 2012 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
JPJaehoon Park
Jaehoon Park
KPKun-Sik Park
Kun-Sik Park
YJYe-Sul Jeong
Ye-Sul Jeong
KBKyu-Ha Baek
Kyu-Ha Baek
BLBong Kuk Lee
Bong Kuk Lee
JCJong Sun Choi
Jong Sun Choi
The influence of tetrafluoromethane (CF4) gas on the electrical characteristics of monolithic graphene field-effect transistors (FETs) is reported. Compared with the results in nitrogen ambient, FETs in CF4 ambient exhibit a positive shift in the Dirac point voltage and an increase in drain current. These changes are ascribed to the electronegative nature of the fluorine atoms in CF4 gas, which is found to induce p-type doping and excess charge carriers in graphene. The electrical response to CF4 gas exposure demonstrates the feasibility of using monolithic graphene FETs as chemical sensors.

10 September 2025 in Agriculture
Verified
Journal Article
Open access
PDF file
SSSookeun Song
Sookeun Song
MJMinseo Jo
Minseo Jo
BLBong Kuk Lee
Bong Kuk Lee
SLSangkeum Lee
Sangkeum Lee
HYHyunbean Yi
Hyunbean Yi
Determining sow (Sus scrofa domesticus Erxleben) estrus status requires considerable labor investment, and continuous real-time monitoring is impractical. Workers typically identify estrus at scheduled intervals and determine artificial insemination timing based on experience. However, experience-based methods are subjective, vary with operator expertise, and impede standardized management in large-scale farms. This study employs cameras and deep learning to detect sows and analyze postural changes, enabling estrus detection and optimal insemination timing prediction. Experimental results indicate that the proposed method achieved an accuracy of 70% (42/60), where the recommended insemination timing differed by less than 24 h from human decisions. This approach facilitates data-driven estrus detection and insemination scheduling, potentially reducing labor intensity and improving reproductive outcomes, particularly beneficial for labor-intensive and large-scale swine production systems.