29 August 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
MLMax Lihs
Max Lihs
FKFinn Knüppel
Finn Knüppel
BTBenjamin Torner
Benjamin Torner
MHMario Hahne
Mario Hahne
CWCalvin Wolfgramm
Calvin Wolfgramm
FWFrank-Hendrik Wurm
Frank-Hendrik Wurm
To better understand the actual flow fields in blood-contacting mechanical medical devices, such as ventricular assist devices (VADs), accurate in vitro and in silico studies are essential. Traditionally, these studies have treated blood as a single-phase fluid. In reality, however, blood is a multi-phase fluid consisting of plasma and suspended blood cells. Cell migration leads to heterogeneous cell distribution, which significantly impacts flow dynamics, particularly in the narrow gaps of these devices. This migration is not usually considered in in vitro analyses using blood analog fluids or in in silico simulations of VADs. This study presents an advanced viscosity modeling approach that accounts for cell migration effects under gap-relevant conditions. The model is based on local particle distribution data obtained from experiments with blood and particle-laden blood analog fluids in microchannels. It is applicable to both blood and particle-laden blood analog fluids, covering gap heights of 150 µm, Reynolds numbers in the range of 50 < Re < 150 and particle volume fractions of up to 30%. Previous works have investigated blood flows with significantly lower volume fractions of up to 5%. The model’s accuracy was validated by comparing results with experimental data on pressure losses of blood flowing through a microchannel, demonstrating good agreement. By incorporating variations in local viscosity, this enhanced viscosity distribution model improves the accuracy of flow simulations, offering a more realistic representation of blood flow in narrow gaps compared to the single-phase assumption. Future work will extend the model to accommodate physiological particle volume fractions of up to 45%.

1 January 2025
Verified
Conference Paper
Open access
PDF file
MHMario Hahne
Mario Hahne
BTBenjamin Torner
Benjamin Torner
FWFrank-Hendrik Wurm
Frank-Hendrik Wurm
Complex flows, such as those in pumps, are highly sensitive to various parameters, where even small changes can significantly alter flow conditions. Transient complex flow phenomena are particularly pronounced in the side chambers of radial pumps, along with the exchange flow between the side chamber, impeller, and volute. These flow phenomena dominate the resulting axial forces on the impeller. Especially in partial load condition, the flow and resulting axial forces changes significantly and can even reverse directions. This paper investigates the influence of the operating point and gap width on the flow in the impeller side chambers and the resulting axial forces. The study focuses on a radial pump with a low specific rotational speed of 13 rpm. High-fidelity simulations and experiments are used for this purpose. The simulation method utilized is the Stress-Blended Eddy Simulation (SBES), a hybrid LES-URANS method. The simulation setup is optimized to primarily resolve the core flow using LES, with a k-omega-SST (URANS) model applied only in the immediate vicinity of the wall. These high-fidelity simulations enable the identification and analysis of secondary flows in the impeller side chambers. In the experiments, pressure distributions in both side chambers, in the volute, and in the gap are analyzed. The pressure in the side chambers is measured at approximately 200 positions using pin-holes. Additionally, measurements of the wall shear stresses using a floating element sensor in the front side chamber are foreseen. The results demonstrate a dominant influence of the gap width and operating point on side chamber flow and the resulting axial forces. The pressure difference between the impeller outlet and the gap induces significant exchange flows between the side chambers, the volute, and the impeller. The paper presents a detailed analysis of the resulting axial forces as functions of gap width and operating point.