This paper reports a comparative study on kinetics of organic matter expressed as BOD5 and nitrogen removal in constructed wetlands operated in Poland. Analyzed data were collected at eight wetland systems, composed of subsurface flow beds: horizontal flow (HF) and vertical flow (VF), in different number and sequences. The analysis involved particularly mass removal rates (MRR) and first-order removal rate coefficients of BOD5 and total nitrogen (kA and kv for VF and HF filters, respectively, and k20 as a parameter averaged for a temperature of 20 °C). It was found that the higher the load of pollutants applied to the beds, the higher MRR values were obtained. The average k-rates in analyzed systems were mostly lower than those reported in the literature, especially in the case of total nitrogen. Its removal obtained in horizontal flow beds was kv = 0.002-0.042 d-1, while in vertical flow systems kA varied from 0.007 m d-1 to 0.0037 m d-1. According to data given by previous studies, first-order reaction rates for nitrogen removal varied in range from kv = 0.048 d-1 to kv = 0.19 d-1 and kA from 0.007 to 0.1 m d-1 in HF and VF beds, respectively. Regarding BOD5 shown in literature, removal rate kv for HF beds varied from 0.071 to 6.11 d-1, and kA for VF beds varied from 0.019 to 1.0 m d-1, while in this study lower k-rates were obtained: kv = 0.005-0.085 d-1 and kA = 0.015-0.130 m d-1. Relatively long monitoring period, for some of constructed wetland up to 16 years, resulted in good data set and enables creation of the graphs, which could be helpful in evaluation and designing of constructed wetlands for PE bigger than 50, in moderate climate conditions.
1 October 2017 in Separation and Purification Technology
This paper presents the use of multi-criteria analysis as a tool that helps choosing an adequate technology for a household wastewater treatment plant. In the process of selection the criteria of sustainable development were taken into account. Five municipal mechanical-biological treatment plants were chosen for the comparative multi-criteria analysis. Different treatment technologies, such as sand filter, activated sludge, trickling filter, a hybrid system - activated sludge/trickling filter and a hybrid constructed wetland system VF-HF type (vertical and horizontal fl ow) were taken into account. The plants’ capacities were 1 m3∙d-1 (PE=8) and they all meet the environmental regulations. Additionally, a solution with a drainage system was included into the analysis. On the basis of multi-criteria analysis it was found that the preferred wastewater treatment technologies, consistent with the principles of sustainable development, were a sand filter and a hybrid constructed wetland type VF-HF. A drainage system was chosen as the best solution due to the economic criteria, however, taking into consideration the primary (ecological) criterion, employment of such systems on a larger scale disagree with the principles of sustainable development. It was found that activated sludge is the least favourable technology. The analysis showed that this technology is not compatible with the principles of sustainable development, due to a lack of proper technological stability and low reliability.
1 September 2016 in Archives of Environmental Protection
The paper presents preliminary results of investigations on a relationship between turbidity and other quality parameters in the SBR plant effluent. The laboratory tests demonstrated a high correlation between an effluent turbidity and a total suspended solids (TSS) concentration as well as between TSS and COD. Such a relationship would help to continuously monitor and control quality of a wastewater discharge using turbidity measurement.
The purpose of this paper is to discuss the problem of changes of effectiveness of Kickuth-type constructed wetland with subsurface flow applied to domestic wastewater treatment. This study is based on an example of a wetland 3000 m2 in surface, serving 800 inhabitants, located in Poland. The results of chemical analysis showed that after an initial year of 'start-up time', the efficiency of pollutant removal gradually increased to reach an apex in the 6th year of operation. Such maximum efficiency continued up to the 10th year of operation; afterwards it gradually dropped. Moreover, after 12 years of operation, a serious problem with overland flow was observed, which indicated the porous media clogging processes.
Many municipal wastewater treatment plants are retrofitted with membrane filtration that replaces secondary clarification. Such a solution saves space and improves overall treatment efficiency but at the cost of increased energy consumption and reduced potential for energy recovery from sewage sludge. Thus, the plant takes a step back from reaching energy self-sufficiency. In the presented case study, two alternative upgrade options were simulated for a medium-size municipal wastewater treatment plant in Poland: the first one assumed optimization of the existing bioreactor, and the other – installation of microfiltration membrane units inside the bioreactor. In both cases, anaerobic digestion of waste sludge with biogas utilization is planned. The results have shown that while under both upgrade options, the plant's capacity can be effectively increased by approximately 50%, their effects on the plant's energy balance will be very different. Although the installation of membrane modules accompanied by the construction of anaerobic digestion tanks improves the plant's energy balance, it will remain negative. The option of optimizing the existing biological treatment system produces a positive energy balance with more energy produced from biogas than consumed. Thus, the plant is able to approach energy self-sufficiency. It has been concluded that retrofitting the plants with membrane filtration is not always the best option from the energy balance point of view and it should be preceded with a detailed analysis on a case-by-case basis.