NAVONITA SHARMA

Dr. NAVONITA SHARMA

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016
Verified
Conference Paper
Closed access
ACAjoy Kumar Chakraborty
Ajoy Kumar Chakraborty
NSNAVONITA SHARMA
NAVONITA SHARMA
Smart Grid has evolved as a recent topic of discussion and research in many parts of the world and thus the smart metering systems. The electrical supply industry is in the process of integration with bidirectional information and power flow infrastructure commonly called smart grid. In laymen's terms Smart grid is the integration of Information Technology and Electrical Grid. Advance metering infrastructure (AMI) is an important component of the smart grid in which data and signal are transferred from consumer smart meter to smart grid and vice versa. In this work, design of smart meter scheme, its hardware and software requirements, and its technologies has been discussed. This paper also focuses on the communication protocol developments as well as information security associate with smart meters. A detailed discussion on the financial and other technological issues related to smart meter has been presented in this paper and a few remedies have also been suggested.

1 May 2016
Verified
Conference Paper
Closed access
ACAjoy Kumar Chakraborty
Ajoy Kumar Chakraborty
NSNAVONITA SHARMA
NAVONITA SHARMA
Permanent magnet synchronous motors (PMSM) are mainly used in high-performance and high-efficiency motor drives such as used in railways. PMSM has the performance required for traction motors and is more compact, light weighted and efficient than induction motors. This paper presents the detailed modeling of PMSM drive in Simulink environment and also presents the speed control of PMSM using vector control approach and by use of state feedback (SFB) controller. The observer is designed to eliminate the need of sensors. The observer is designed for estimating any one of the state variable if the other state variable is known thus eliminating the need to sense both speed and current. The state feedback (SFB) controller is designed such to provide zero steady state error. For observation purpose a PI controller is also designed and the results of control actions have been compared and observed that SFB controller are more robust than PI controllers bpth in case of normal and over loading. In this paper, we have designed and simulated the mathematical model of PM synchronous motor and designed the state feedback control system using pole placement method and PI controller using bode plot method, for speed control of PMSM. The controller hence designed is found to be satisfactory and robust over wide range of operating condition and parameter variations.

28 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
NSNAVONITA SHARMA
NAVONITA SHARMA
ACAjoy Kumar Chakraborty
Ajoy Kumar Chakraborty
In this paper, an introduction and comprehensive analysis have been presented for the implementation and application of modern smart meters which include Unbundled Smart Meters (USM) and Next-Generation Open Real-Time Smart Meters (NORM). This article also contributes to methods through which USM and NORM could provide a better perspective to the already available technologies for grid-tied-inverter controlled feeding renewables to the grid. The research proposes a next-generation smart meter model with the feature of a phasor measurement unit. The meter is further integrated with a controller board that controls the power injection from the inverter to the grid based on the real-time data obtained from the smart meter. The inverter is simulated with an open-circuit fault and is controlled to provide non-oscillatory power to the grid based on an instantaneous grid power factor or phase requirement. The proposed meter has the flexibility to add additional features to control the inverter based on other grid requirements such as active and reactive power control, tariff implementation, etc. This manuscript provides the analytical aspects of the use of smart meters in efficient energy management and also addresses the need for smart technologies for grid modernization.

22 October 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
NSNAVONITA SHARMA
NAVONITA SHARMA
SPSouradeep Pal
Souradeep Pal
MMManas Mishra
Manas Mishra
AVApurva Verma
Apurva Verma
ACAjoy Kumar Chakraborty
Ajoy Kumar Chakraborty
ACAbanishwar Chakrabarti
Abanishwar Chakrabarti
An open circuit fault-tolerant operation of a grid connected inverter requires switching reconfigurations or redundant inverter leg to bypass the faulty device. Such measures led to increased cost and design complexities. In the absence of such reconfiguration mechanisms, a grid-connected inverter with an open-circuit fault in one of the inverter leg injects negative sequence current into the grid. The negative sequence current causes oscillation in DC-link voltage and thereby inject lower order harmonic into the grid. The present work proposes a novel control strategy (Open Circuit Non-Oscillatory Power- OCNOP) to deliver a steady power into a balanced three phase grid with only two active legs of the grid connected inverter. The current of these two active phases are controlled to be equal in magnitude and 60° phase apart. This inhibits the flow of negative sequence current and in turn limits the lower order harmonic injection within the permissible limit. A control strategy is also proposed to modify the power references during post fault operation so that the post fault current in two active phases are limited within the converter current rating. The performance of the proposed scheme is compared with the conventional vector control scheme through a simulation study. The simulation results for the proposed control scheme are verified through experimental study in a laboratory prototype.

12 June 2023 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
ACAbanishwar Chakrabarti
Abanishwar Chakrabarti
NSNAVONITA SHARMA
NAVONITA SHARMA
PKPrabir Ranjan Kasari
Prabir Ranjan Kasari
BDBikram Das
Bikram Das
SBSujit K. Biswas
Sujit K. Biswas
A retrofit solution is proposed in this article for providing fault-tolerant capability in the existing three-leg grid synchronized converter operating at unity displacement factor, during open circuit fault of one of its phases. During such a fault, the scheme controls the current in the two operative phases of the converter for equal magnitude with a mutual phase shift of 60°. This 60° phase-shifted two-phase current is distributed as a balanced three-phase grid current at unity displacement factor, using an existing Δ-Y isolation transformer or a lower power-rated zig-zag autotransformer. Existing fault-tolerant schemes are applicable only if the device or its driver fails, with the addition of hardware in the form of the redundant leg for the total failure of one phase of the converter. In retrofit application, the proposed scheme modifies the control logic and does not require modification in the controller hardware circuit or addition of a leg in the converter power circuit. Hence, it can be conveniently implemented to add fault-tolerant capability to an existing three-leg voltage source converter in either an inversion or rectification mode of operation. In addition to semiconductor failure, the proposed scheme is applicable during an open-circuit fault in other parts of the circuit viz., line reactor, connecting wire, transformer, etc., which is not possible using the existing fault-tolerant techniques. Simulation and experimental results are provided to validate the proposed concept.

1 December 2017
Verified
Conference Paper
Closed access
NSNAVONITA SHARMA
NAVONITA SHARMA
ACAjoy Kumar Chakraborty
Ajoy Kumar Chakraborty
ACAbanishwar Chakraborti
Abanishwar Chakraborti
In this paper, we proposed a smart energy meter prototype with the feature of three-phase inverter control that is supplied by a solar PV system and is connected to a grid. The inverter is controlled according to grid requirement and hence promotes the optimized penetrations of renewable to the grid. The smart meter designed has been incorporated with the feature of active and reactive power control. The controller is placed in the design of smart meter to eliminate the need of excess control system for controlling grid-connected inverters. This approach has been taken into account considering the need of inverter control for renewable integration in smart grid and hence including the control design in the smart energy meter can eliminate the use of excess equipment and also reduces the cost involved. This paper also describes the various literatures involved for control of grid connected inverter for non-ideal grid connections and also shows how the present system can be more efficient and cost effective for renewable integration with the grid system.