Multi-Level Inverters (MLI) has wide applications due to their numerous advantages. An improved configuration of eleven-level MLI suitable for medium voltage range has been proposed in this paper. The proposed topology contains two half-bridge sub-modules (HBSM), one flying capacitor (FC) MLI and one full bridge sub-module (FBSM). A simple method of capacitor voltages balancing (CVB) has been demonstrated with less ripple. The study about the effectiveness of proposed MLI has been justified by loss calculation to find efficiency and voltage ripple analysis of capacitor. The comparative assessment in terms of switch count, driver count, capacitor requirement, device peak inverse voltage (PIV), total standing voltage (TSVp.u), cost function etc. for developed hybrid inverter (HI) topology has been presented to establish the utility of the proposed HI. This topology has been checked for its operation under various operating conditions including frequency and modulation index (MI) variation, over-modulation range and also with motor load. The grid connectivity option of the proposed HI has been verified to ensure the suitability for application with renewables.
8 September 2020 in IEEE Transactions on Industry Applications
This paper proposes the integration of a battery energy storage system in a doubly-fed induction generator based wind energy conversion system. A modified triple star bridge cell converter is proposed for the control of doubly fed induction generator and battery energy storage system. The modular structure of the converter facilitates the integration of large energy storage using low rated converters. A median filter is used to segregate the fluctuating component of power generation because of wind speed variation. A control strategy is proposed to mitigate a part of this fluctuation within the rating of the battery energy storage system thereby reducing the fluctuation of power fed to the grid. Wind velocity at an interval of 30second is obtained from online resources and the performance of the proposed algorithm is evaluated via a simulation study. A wind turbine is emulated in a separately excited DC motor and the performance of the proposed scheme is experimentally validated in a laboratory prototype
3 October 2022 in IEEE Transactions on Industrial Electronics
A generalized Carrier-Based Pulse Width Modulation (CB-PWM) scheme is proposed here for the elimination of common-mode voltage (CMV) in a multilevel multiphase voltage source inverter (VSI). In this CB-PWM scheme, the switching function of x-level, q-phase VSI is obtained from the switching function of virtual y-level and (y+1) level, q-phase VSI, where y = (x+1)/2 when x is odd and y = x/2 when x is even. It is established here that the pole voltages of q-phase x-level VSI thus obtained generate zero CMV. The proposed CB-PWM technique is computationally less intensive and hence can be easily implemented in hardware. Extensive simulation and experimental results are presented to validate the proposed CMV elimination technique in 3-phase 7-level VSI, 5-phase 5-level VSI, and 6-phase 4-level VSI. A comparative study of the proposed PWM scheme with the existing technique shows the superiority of the proposed technique in eliminating CMV.
30 December 2024 in IEEE Transactions on Industry Applications
This article presents a fast and accurate active islanding detection scheme for a grid-tied voltage source inverter (VSI). In the proposed scheme, the VSI generates a small negative sequence voltage to continuously inject a small negative sequence current into the system. The voltage at the point of common coupling (PCC) is measured and the negative sequence component of PCC voltage is extracted. The negative sequence voltage generated by the VSI and the negative sequence voltage at PCC are combined to yield a time-invariant coefficient, which is proposed here to be used for islanding detection. In case detection is done solely based on the magnitude of negative sequence voltage at PCC, higher threshold has to be set as a small magnitude of negative sequence voltage at PCC may also be present due to grid unbalance and other transient events. In the proposed scheme, the islanding detection coefficient depends on the similarity between the injected and measured negative sequence voltage and hence is not dependent on the absolute magnitude of the negative sequence voltage. Thus a very low magnitude of negative sequence current can be injected to effectively detect islanding conditions without a significant impact on power quality. Simulation results show that the proposed scheme is effective for unbalanced grid voltage, or unbalanced load, even in the presence of noise in acquired data. Experimental studies on a laboratory prototype validate the performance of the proposed islanding detection scheme.
29 June 2023 in IEEE Transactions on Industry Applications
This article proposes an energy efficient 5-level neutral point clamped (NPC) inverter based boost inverter topology for transformer-less medium voltage high power Open End Induction Motor (OEIM) drive. A conventional boost circuit cannot be used in such drives as single semiconductor device may not be able to block the total dc link voltage and simultaneously carry full load current. In the proposed scheme, two partly rated soft switched isolated dc-dc converters which generate only the required boost fraction of the voltage are connected in cascade with the two ends of the input dc bus. The input dc is divided into two equal parts using a capacitor voltage divider circuit. These four effective voltage sources in cascade serve as the four dc bus for the two five level NPC VSI of the OEIM drive. A substantial amount of power directly flows to the inverter through the capacitor voltage divider circuit and hence the size as well as power loss of the dc-dc converter of the proposed scheme is much smaller. The voltage generated from the dc-dc converter is lower than the voltage in the capacitor voltage divider circuit, creating unequal step heights in the pole voltage of the 5-level NPC VSI. These unequal steps in the pole voltage of the two VSI of open end drive restrict the use of existing technique for operating an OEIM drive from a single dc source. In this article, a carrier based PWM technique is proposed to restrict the circulating current caused by CMV even when the voltage steps are unequal.
22 October 2020 in IEEE Transactions on Industry Applications
An open circuit fault-tolerant operation of a grid connected inverter requires switching reconfigurations or redundant inverter leg to bypass the faulty device. Such measures led to increased cost and design complexities. In the absence of such reconfiguration mechanisms, a grid-connected inverter with an open-circuit fault in one of the inverter leg injects negative sequence current into the grid. The negative sequence current causes oscillation in DC-link voltage and thereby inject lower order harmonic into the grid. The present work proposes a novel control strategy (Open Circuit Non-Oscillatory Power- OCNOP) to deliver a steady power into a balanced three phase grid with only two active legs of the grid connected inverter. The current of these two active phases are controlled to be equal in magnitude and 60° phase apart. This inhibits the flow of negative sequence current and in turn limits the lower order harmonic injection within the permissible limit. A control strategy is also proposed to modify the power references during post fault operation so that the post fault current in two active phases are limited within the converter current rating. The performance of the proposed scheme is compared with the conventional vector control scheme through a simulation study. The simulation results for the proposed control scheme are verified through experimental study in a laboratory prototype.