Taeyoon Park

Dr. Taeyoon Park

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
TPTaeyoon Park
Taeyoon Park
SLSeung-Eun Lee
Seung-Eun Lee
Sang-Yoon ParkSang-Yoon Park
Sang-Yoon Park
SOSung Woon On
Sung Woon On
SYSangmin Yi
Sangmin Yi
Soohwan ByunSoohwan Byun
Soohwan Byun
Cone-beam computed tomography (CBCT) plays an important role in dental diagnosis; however, radiation exposure remains a concern. This study evaluated the feasibility of artificial intelligence (AI)-based image processing for improving image quality in low-dose CBCT. CBCT scans were acquired from a single healthy adult male at three radiation dose levels (10%, 20%, and 100% of the standard dose), and each dataset was subsequently processed using an AI-based image enhancement model. Five dental specialists independently assessed image quality using a 6-point scoring system across 12 anatomical and diagnostic criteria, including anatomical visibility, structural delineation, and overall diagnostic acceptability. The AI-processed 20% dose images showed no statistically significant difference in image quality compared with the 100% raw dose images (median 4.45, range 3.50–5.30 vs. median 5.05, range 4.50–5.50; p > 0.05). In contrast, the AI-processed 10% dose images demonstrated significantly lower scores (p = 0.0074), and the AI-processed 100% dose images were rated lower than the corresponding raw images. These preliminary findings suggest that AI-assisted enhancement may partially mitigate image quality degradation associated with moderate CBCT dose reduction. Further large-scale studies involving diverse patient populations and clinical settings are required to validate these results.

Verified
Journal Article
Open access
PDF file
Sang-Yoon ParkSang-Yoon Park
Sang-Yoon Park
SOSung Woon On
Sung Woon On
TPTaeyoon Park
Taeyoon Park
SCSeungwon Cho
Seungwon Cho
SYSangmin Yi
Sangmin Yi
Byoung-Eun YangByoung-Eun Yang
Byoung-Eun Yang
This randomized controlled clinical trial compared a conventional combined screw- and cement-retained prosthesis (CSCRP) workflow (control group) with a fully digital cementless screw-retained prosthesis (CL-SRP) system (test group) for single posterior implant restorations. A total of 40 implants in 35 patients were allocated to either workflow. Clinical procedure times, prosthetic accuracy, peri-implant soft tissue changes, and marginal bone loss (MBL) were assessed. The test group demonstrated significantly shorter total prosthetic time (p < 0.001) and impression-taking time (p < 0.001) compared with the control group. Prosthetic adjustment time (p = 0.211) and adjustment volume (p = 0.474) did not differ significantly. Gingival shape changes were likewise not statistically significant (p = 0.966). MBL was significantly lower in the test group (p < 0.05). From a prosthetic standpoint, both workflows yielded clinically acceptable outcomes; however, the digital CL-SRP approach improved procedural efficiency and early peri-implant bone preservation without compromising prosthetic quality. This trial had inherent limitations, including a short follow-up duration, a relatively small sample size, combined test conditions, and restriction to single posterior implants. Therefore, further long-term studies are warranted to confirm durability and broader clinical applicability.