Energy feedback systems (EFSs) have been widely applied in urban rail transit, and a power flow algorithm and energy-saving evaluation of urban rail power supply systems with EFSs are studied in this paper. First, trains, the reflux system, and traction substations with EFSs are modeled, and the multimode transitions are analyzed, including the maximum power state of the EFS. Then, a modified AC/DC unified power flow algorithm for the DC power supply system, which simplified the DC reflux system is proposed, and a field case study based on a multiple train scenario is presented to validate the algorithm. Furthermore, system-level energy-saving evaluation indexes are applied according to system power flow analysis. When the headway time decreases, the proposed indexes decrease in general mainly as there is more regenerative braking energy absorbed by adjacent trains. The higher the load rates of the step-down substations are, the more daily feedback energy is utilized. When the start voltage of the EFS ranges from 1650 V to 1770 V, the maximum energy-saving rate reaches 11.9%, which occurs when the start voltage is 1670 V. When the no-load voltage is relatively high, the start voltage should not be higher than 1750 V to keep the system running in high efficiency. These results can provide advice for the design and operation of traction power supply systems with EFSs.
31 January 2023 in IEEE Transactions on Power Delivery
The dynamic fluctuation of stray current is the main characteristic of the metro causing harm to surrounding buried metal structures. While establishing the equivalent circuit model of the return system, not only mainline but also metro depot should be considered. The diffusion models of the dynamic stray current of the DC traction power supply system (DTS) in multi-layer soil medium and massive texture soil medium are established. They are co-simulated with the DC traction power supply return system. The massive texture model (MTSM) is verified by an on-site experiment of ground potential distribution. In the case study, the direct grounding of the rail in the depot will deteriorate the ground potential gradient and stray current. When considering the impact of the river or lake, the stray current easily flows to the low resistivity texture soil, the maximum ground potential gradient increases.
2 September 2021 in IET Generation, Transmission & Distribution
The bidirectional converter device (BCD) can substitute the substation rectifier and the energy feedback system (EFS) by transforming energy between the AC side and DC side. However, the performance of the railway system with BCDs as only converters has not been fully understood. A simulation approach is required to evaluate the system performance and guide the design. In this paper, the traction power supply system considering the capacity constraint of BCDs is modelled first, and the AC/DC power calculating algorithm is studied. A three‐layer double‐loop parameter designing strategy based on the enhanced brute force is proposed, which considers the N −1 principle. In the case study, the power source model for trains and power constraint for BCDs are verified. The boundary configuration set is obtained. The capacity of BCDs is at least 7 MW, while the slope is 0 and the no‐load voltage is between 1730 and 1750 V. Finally, compared with the system with rectifiers and EFSs, the system with BCDs has better performance, which is 46.7 V less of the rail potential, 127.8 V less of network voltage fluctuation, and 735.56 kWh per hour more of the feedback energy.
8 March 2023 in IEEE Transactions on Transportation Electrification
In the power supply system with energy feedback system (EFS)s, the energy from EFS (WF) will flow to rectifiers, which is circulation flow (CF). However, the efficiency of CF between substations has been rarely studied. Besides, the relationship between the train operation and regenerative braking energy (RBE) utilizing efficiency is not clear. In this paper, the energy flow structure of the AC/DC railway power supply system including CF is established. In the double-train system, promoting CF when the trains’ distance is long can be beneficial to power utilization efficiency. Chengdu Metro Line 9 is analyzed as the multi-train system based on the iterative AC/DC power flow algorithm. The key to energy saving includes reducing the energy consumption of on-board resistance and the DC traction network loss. Compared with the catenary and rail system, the fourth-rail system can promote system energy efficiency by 23.5% at most. The CF and energy fed to main substations counts for less than 2% and 8% of WF. When the headway time is short, RBE should be avoided feedback to EFS, while the feedback power of EFS should be advocated when the headway time is long. The results can help guide the operation of urban rail to save energy.
4 April 2022 in IEEE Transactions on Power Delivery
Auditing the energy consumption in urban rail is vital for energy consumption evaluation and system parameter design. There are multiple ways to audit energy consumption, but a universal and global approach is missing. The system-level traction energy consumption (STEC) is proposed. Compared to the main substation energy consumption (MSEC), STEC is more accurate by eliminating the influence of step-down loads based on field test studies. An optimization parameter designing model is built, which takes the system cost as the optimal object considering the life span of energy feedback system (EFS)s. The modified salp swarm algorithm (MSSA) is proposed as the optimization algorithm. The numerical tests show that MSSA has better converge performance than salp swarm algorithm (SSA) and particle swarm optimization (PSO). The impact factors of STEC are analyzed. Compared with SSA and PSO, the initial value of the MSSA is improved and it evolves faster. Compared with the case that does not take the no-load voltage of rectifiers and start voltage of EFSs as optimal parameters, the composite cost of the case that takes the abovementioned parameters as optimal parameters is 3.49% less. Compared to the system without EFSs, the optimal system with EFSs can save costs by 29.47%.
28 July 2021 in IET Generation, Transmission & Distribution
With the large‐scale increasing demand for passenger transportation, the alternating current (AC) 25 kV traction power supply system (TPSS) of electrified railway is introduced into the construction of urban rail transit in China instead of the direct current (DC) TPSS. In order to suppress the negative sequence current and cancel the neutral section at the exit of traction substation of the AC TPSS, a novel AC integrated power supply system (IPSS) of the urban rail transit based on single‐phase static var generator (SVG) is proposed, which the capacity of SVGs can be further reduced. The topology of the novel AC IPSS is introduced. By defining the constraint factors of negative sequence current and reactive power compensated, the comprehensive compensation model of negative sequence current and reactive power of the novel system is established based on the corresponding standards, which the full compensation and satisfactory compensation can be achieved. The method of determining the compensation scheme and the control strategy are proposed. Taking the actual data as an example, the effectiveness of the compensation scheme is proved. In addition, the correctness of the control strategy proposed is proved by simulation and experiment.