G. Gebremichael Elias

Mr. G. Gebremichael Elias


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2021 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
JPJayavelu Udaya Prakash
Jayavelu Udaya Prakash
SPSivaprakasam Palani
Sivaprakasam Palani
IGIlhan Garip
Ilhan Garip
SJS. Jebarose Juliyana
S. Jebarose Juliyana
GEG. Gebremichael Elias
G. Gebremichael Elias
ICIlhami Colak
Ilhami Colak
The present study looks into the effect of WEDM process parameters on the material removal rate (MRR) and surface roughness (SR) responses when machining hybrid composites (Al-Si12/boron carbide/fly ash) using the Taguchi technique. Fly ash and boron carbide (B4C) particles were used for reinforcement (3, 6, and 9 by weight), and aluminium alloy (Al-Si12) was used as a matrix material. ANOVA was used to find out the importance of machining factors that affect the quality features of the WEDM process, as well as the relative role of input parameters in determining the WEDM process responses. The greatest impact on the response is finalised by the signal-to-noise (S/N) ratio response analysis. However, as a last step, a confirmation experiment with the best combination was carried out to predict and validate the accuracy of the observed values. As the pulse on time and reinforcement increases, MRR also increases. As the gap voltage, wire feed, and pulse off time decrease, it increases. SR is increased by increasing the gap voltage, pulse on time, and pulse off time, wire feed, and reinforcement. The maximum MRR of 38.01mm3/min and the minimum SR of 3.24μm were obtained using optimal machining conditions.

12 October 2021 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
JXJ. Francis Xavier
J. Francis Xavier
BRB. Ravi
B. Ravi
DJD. Jayabalakrishnan
D. Jayabalakrishnan
CEChakaravarthy Ezilarasan
Chakaravarthy Ezilarasan
JVJayaseelan Veerasundaram
Jayaseelan Veerasundaram
GEG. Gebremichael Elias
G. Gebremichael Elias
Aircraft component manufacturing sector is looking for high precision machining in aircraft components. The present work explores the operability of green manufacturing of Nimonic C263 using dry turning. Nimonic C263 is tough to turn owing to its inherent quality like low conductivity and more work hardening. Therefore, in order to improve this machined surface/integrity, the controlling factors were optimized based on desirability approach for minimum of surface roughness and flank wear during turning of this alloy using CBN insert. L27 orthogonal array was chosen to carry out the experiment. The effects of controlling factors, such as cutting speed (), feed rate (), and cut penetration/depth of cut () on the outputs, were also explored. The feed rate was a major impact to affect surface finish and flank wear. The average error percentage between the experimental and RSM models for surface finish was 4.76 percent and 2.79 percent for flank wear.

7 May 2020 in International Journal of Ambient Energy
Verified
Journal Article
Closed access
SPSivaprakasam Palani
Sivaprakasam Palani
PHP. Hariharan
P. Hariharan
GEG. Gebremichael Elias
G. Gebremichael Elias
Micro Electric Discharge Machining (Micro-EDM) is an established machining process for making very small parts/components with accuracy and superior surface finish. The present work, investigates the magnetic field assisted Micro-EDM of inconel alloy with Tungsten electrode using Response Surface Methodology (RSM). The experiments were carried out based on RSM design of experiments, especially face center cubic design with and without magnetic field assistance on Micro-EDM processes. The machining parameters for experimental design are voltage; capacitance and feed rate each varying at three levels. Material removal rate (MRR) is the response parameter. Mathematical model was developed for prediction of MRR based on RSM methods. Analysis of variance was used to check the significance of model of MRR for both machining processes. The experimental observation shows that voltage, capacitance and its interactions are significant on the MRR. The MRR of magnetic field assisted Micro-EDM is 22% more than the MRR of non-magnetic field assisted Micro-EDM.

1 January 2021 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
Sridhar JayaprakashSridhar Jayaprakash
Sridhar Jayaprakash
JDJegatheeswaran Dhanapal
Jegatheeswaran Dhanapal
VDVivek D
Vivek D
GEG. Gebremichael Elias
G. Gebremichael Elias
Bending tests were conducted on ferrocement laminates containing chicken mesh and steel slag. The fundamental goal of the examination was to investigate the effects of partial substitution of fine aggregate by steel slag in cement mortar combining chicken mesh of different volume fractions as reinforcement in thin ferrocement laminates. The following variables were investigated: (a) volume fraction of chicken mesh as 0.94%, 1.88%, 2.82%, and 3.77% and (b) level of steel slag substitution from 0% to 50% by weight fine aggregate. Results show that ferrocement laminates with chicken mesh of volume fractions of 3.77% and 30% substitution of fine aggregate with steel slag display better performance in terms of load deflection behaviour, first crack load, ultimate load, energy absorption, and ductility ratio when related with other specimens. An analytical model has been proposed to predict the ultimate moment carrying capacity of ferrocement laminates under flexure to validate the experimental results.

1 January 2021 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
GRGokulan Ravindiran
Gokulan Ravindiran
PSPradeepkumar Sugumar
Pradeepkumar Sugumar
GEG. Gebremichael Elias
G. Gebremichael Elias
An ever increase in the utilization of water for domestic and industrial activities resulted in the depletion of fresh water. Water is being used in huge quantities for manufacturing and other activities. The toxic pollutants used in the industries get mixed with water and result in the degradation of water quality. Textile industries are considered as one of the major industries that release a huge quantity of wastewater. The dye used in the textile industries is not completely utilized in the dyeing process and gets mixed with water and reaches the environment. Caulerpa scalpelliformis, a novel sorbent, was used for the preparation of biochar and successive removal of dyes in a continuous operation. The operating conditions, namely, biochar bed depth, dye flow rate, and initial dye concentration, were investigated, and the experimental result was validated with the mathematical models.

1 January 2021 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
SPSivaprakasam Palani
Sivaprakasam Palani
AKA. Kirubel
A. Kirubel
GEG. Gebremichael Elias
G. Gebremichael Elias
PPP. Maheandera Prabu
P. Maheandera Prabu
PBP. Balasubramani
P. Balasubramani
In this study, the wear behavior of a physical vapor deposition (PVD) AlTiN coated on the titanium alloy was investigated. Response surface methodology (RSM) was used to analyze input factors, such as load (A), sliding speed (B), and sliding distance (C), while wear mass loss (WML) and coefficient of driction (COF) were considered as the response parameters. The statistical analysis shows that main factors, that is, interaction of AC and pure quadratic terms B2 and C2, have maximum influences on WML. However, COF was highly affected by load, sliding speed, and interaction of AB and quadratic term A2. The present work attempts to carry out empirical modeling to predict output response on WML and COF. Desirability‐based optimization technique was employed to obtain minimum WML and COF. Microscopy images of the wear tracks reveal visible grooves and scratches that confirm abrasive wear to be the primary wear mechanism accompanied by adhesive wear. The investigation concluded that AlTiN has better wear resistance properties and can be used to coat titanium implants for biomedical application. The result shows that the minimum WML and COF have been found at applied load 15 N, sliding speed at 0.5 m/s, and sliding distance 500 m.