David Auslander

Prof. David Auslander

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2005 in Journal of Electronic Packaging
Verified
Journal Article
Closed access
PDF file
TBTimothy D. Boucher
Timothy D. Boucher
DADavid Auslander
David Auslander
CBCullen E. Bash
Cullen E. Bash
CFClifford C. Federspiel
Clifford C. Federspiel
CPChandrakant D. Patel
Chandrakant D. Patel
Data center thermal management challenges have been steadily increasing over the past few years due to rack level power density increases resulting from system level compaction. These challenges have been compounded by antiquated environmental control strategies designed for low power density installations and for the worst-case heat dissipation rates in the computer systems. Current data center environmental control strategies are not energy efficient when applied to the highly dynamic, high power density data centers of the future. Current techniques control the computer room air conditioning units (CRACs) based on the return air temperature of the air—typically set near 20°C. Blowers within the CRACs are normally operated at maximum flow rate throughout the operation of the data center unless they are equipped with nonstandard variable frequency drives. At this setting the blowers typically provide significantly more airflow than is required by the equipment racks to prevent recirculation and the subsequent formation of hot spots. This strategy tends to be overly conservative and inefficient. As an example air entering a given system housed in a rack undergoes a temperature rise of 15°C due to the heat added by the system. The return air control strategy strives to keep the entire room at a fixed temperature. Therefore in a typical data center the CRAC supply temperature, and hence the air entering the racks, is 13–15°C and the CRAC return is 20–22°C. At these settings the CRACs can consume almost as much energy as the computer equipment they are cooling [Friedrich, R., Patel, C.D.,2002, “Towards Planetary Scale Computing – Technical Challenges for Next Generation Internet Computing ,” THERMES 2002, Santa Fe, NM; The Uptime Institute, “Heat Density Trends in Data Processing, Computer Systems and Telecommunications Equipment,” White Paper issued by The Uptime Institute, 2000.]. Experiments conducted by the authors using these CRAC settings show that nearly 0.7W is consumed by the environmental control system for every 1W of heat dissipated by the computer equipment in the authors’ experimental facility indicating that the energy efficiency of standard data center environmental control systems is poor. This study examines several opportunities for improving thermal management and energy performance of data centers with automatic control. Experimental results are presented that demonstrate how simple, modular control strategies can be implemented. Furthermore, experimental data is presented that show it is possible to improve the energy performance of a data center by up to 70% over current standards while maintaining proper thermal management conditions.

15 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
HHHamidreza Heidary
Hamidreza Heidary
RAReza Ahmadi
Reza Ahmadi
SRShahram Rasoulian
Shahram Rasoulian
SVSamira Fazeli Veisari
Samira Fazeli Veisari
DADavid Auslander
David Auslander
Amin KomeiliAmin Komeili
Amin Komeili
Asymmetry, defined as unequal neuromuscular activation or mechanical performance between contralateral limbs, plays a critical role in cycling efficiency and injury risk. While kinematic and kinetic measures are commonly used to assess asymmetry, surface electromyography (EMG) signals offer an additional perspective on neuromuscular asymmetry. This study evaluated muscle activation asymmetry during cycling using the Normalized Symmetry Index (NSI), a metric that quantifies differences in kinematics and kinetics between limbs, where higher values indicate greater asymmetry. NSI was calculated from EMG recordings of seven lower-limb muscles under two test conditions: step incremental and constant-power cycling to task failure. Twenty recreationally active participants performed both tests on a stationary ergometer while EMG data were collected bilaterally. Step incremental cycling resulted in a significant reduction in NSI for key muscles in the quadriceps group: vastus medialis (from 44% to 21%, p < 0.001), vastus lateralis (from 45% to 22%, p = 0.002), rectus femoris (from 54% to 24%, p < 0.001), and biceps femoris (from 52% to 29%, p = 0.003). No significant changes were observed for the tibialis anterior, soleus, or gastrocnemius medialis. In contrast, under constant-power conditions, NSI values remained unchanged over time for all muscles (all p > 0.05), with average NSI values ranging from 12% to 30%, indicating consistent bilateral activation. These findings highlight the sensitivity of surface EMG in detecting workload-dependent changes in muscle activation asymmetry and suggest that higher cycling intensities, compared to lower ones, may promote more balanced engagement of primary cycling muscles.

1 February 2021 in ASME Journal of Engineering for Sustainable Buildings and Cities
Verified
Journal Article
Closed access
PDF file
JSJames A. Shia
James A. Shia
DADavid Auslander
David Auslander
About 41% of total energy consumption in the U.S. of year 2014 is used for heating and air conditioning, that is about 40 quadrillion (40×1015) British thermal units (BTU). Despite the fact that people have been working on on fault detection and diagnosis (FDD) for Heating, Ventilation, and Air Conditioning (HVAC) systems for a long time, very few publications have focused on scalability and low cost. In order to address this challenge, we will propose an approach which focuses on control-system data. Several machine learning algorithms are introduced for data exploration and analysis, a control-system data focused model free approach is presented as well, and finally, FDD is carried out by implementing anomaly algorithms. A simulation model is used to evaluate the performance of the various algorithms.

10 May 2002 in Journal of Dynamic Systems, Measurement, and Control
Verified
Journal Article
Closed access
PDF file
PYPai-Hsueh Yang
Pai-Hsueh Yang
DADavid Auslander
David Auslander
This paper discusses the control problem of launching an open-loop unstable system from its resting state on a mechanical hard stop. Smooth state transition with the appropriate control mode is accomplished by fuzzy transition logic. A “soft tracking” algorithm with on-line trajectory planning is then employed to manage the system stabilization immediately following the launch. The strategies have been successfully applied to an experimental system consisting of a hydraulically balanced beam pivoted at its center.

1 January 2005
Verified
Book Chapter
Closed access
PDF file
DADavid Auslander
David Auslander
JDJean-Dominique Decotignie
Jean-Dominique Decotignie