School of Energy and Safety Engineering, Tianjin Chengjian University 1 , Tianjin 300384, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Chunmei GuoChunmei Guo
Chunmei Guo
YLYu Li
Yu Li
XLXianli Li
Xianli Li
RBRuxue Bai
Ruxue Bai
Chuanshuai DongChuanshuai Dong
Chuanshuai Dong
In order to promote the engineering application of indirect evaporative cooling (IEC) in the field of building air conditioning, as well as reduce air conditioning energy consumption and carbon emissions, this paper proposes a fresh air unit using indirect evaporative cooling to achieve heat recovery from exhaust air, which gives the recommended values of air and spray water operation parameters. The indirect evaporative cooler heat and mass transfer mathematical model and numerical solution procedure were made. In summer outdoor design conditions, the fresh air outlet state parameters, cooling capacity, fresh air cooling load, wet bulb efficiency and enthalpy efficiency were numerically solved for thirty typical cities from five climate zones of China. In addition, also based on the model results for the cities in China, two representative operating conditions points of medium and high humidity were selected. Eight models of fresh air unit coolers in the air volume range of 1000–10,000 m3/h commonly used in engineering were simulated to obtain the optimal heat transfer area and size selection of ERIEC heat exchangers for fresh air units, and economic analysis was performed. The results show that the wet bulb efficiency ranges from 0.67–0.98, and increases as the outdoor design wet bulb temperature decreases; the enthalpy efficiency ranges from 0.76–1.29, and increases as the outdoor design wet bulb temperature increases; and the fresh air load that the exhaust air heat recovery type indirect evaporative cooler can bear ranges from 55–100%, which could largely decrease the cold load of the matched surface cooler. As demonstrated, the energy-saving effect is remarkable.

1 September 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
CGChunmei Guo
Chunmei Guo
RBRuxue Bai
Ruxue Bai
RGRong Gao
Rong Gao
YLYu Li
Yu Li
HXHang Xiong
Hang Xiong
LWLeilei Wang
Leilei Wang
Compared to conventional condensation dehumidification systems, a solar liquid desiccant air conditioning system (SLDAC) offers distinct advantages, enabling independent control of temperature and humidity while operating at low carbon levels. This paper proposes a low-carbon SLDAC thermal mass exchange model that uses an indirect evaporative cooling liquid dehumidifier and photovoltaic thermal and air source heat pump for combined driving of the solution regeneration process. The system simulation model was created using MATLAB and TRNSYS software. An experimental comparison was conducted between the dehumidification module and the regeneration module, and the system's performance was simulated with an airflow of 150 m3/h in the Tianjin area. The results indicate an average dehumidification efficiency of 44.03% and a regeneration efficiency of 40.80% throughout the cooling season. During the cooling season, the power generation of the system met the power demand and produced a surplus of 85.36 kWh, achieving overall self-sufficiency in power consumption. The optimized system's operating parameters were proposed, with regeneration temperatures of 57 °C in June and September and 65 °C in July and August. During the cooling season, the system's regeneration capacity exceeded its dehumidification capacity for 84.90% of the operating time. As a result of optimization, the system's carbon emissions were reduced by 59.35%.