Hospitality institutions are significant consumers of water, electricity and gas resources. These resources may be scarce or critical in several locations. Authors have investigated strategies for efficient building operation, considering various energy carriers. Despite reported methods to enhance efficiency, nowadays they commonly have to be integrated into hotels from the design process through regular operation. This study aims to provide a detailed analysis of sustainable architecture in hotel design to decrease resource usage without compromising the quality of services provided. The considered design process is based on using a structured methodology focused on a energy management system that guarantees an efficient use of resources. The present study also considers incorporating renewable energy sources for the nominal operation of the hotel to achieve a net-zero energy building classification. The design of the building resulted in the proposed architecture that can maintain a comfortable temperature range of $17^{\circ } C$ to $24^{\circ } C$ in the guest rooms throughout the year. The energy generated from the proposed photovoltaic, thermal solar systems and rainwater harvesting can guarantee a nearly negligible net consumption of these resources for the hotel.
The present research develops the parametric estimation of a second-order transfer function in its standard form, employing metaheuristic algorithms. For the estimation, the step response with a known amplitude is used. The main contribution of this research is a general method for obtaining a second-order transfer function for any order stable systems via metaheuristic algorithms. Additionally, the Final Value Theorem is used as a restriction to improve the velocity search. The tests show three advantages in using the method proposed in this work concerning similar research and the exact estimation method. The first advantage is that using the Final Value Theorem accelerates the convergence of the metaheuristic algorithms, reducing the error by up to 10 times in the first iterations. The second advantage is that, unlike the analytical method, it is unnecessary to estimate the type of damping that the system has. Finally, the proposed method is adapted to systems of different orders, managing to calculate second-order transfer functions equivalent to higher and lower orders. Response signals to the step of systems of an electrical, mechanical and electromechanical nature were used. In addition, tests were carried out with simulated signals and real signals to observe the behavior of the proposed method. In all cases, transfer functions were obtained to estimate the behavior of the system in a precise way before changes in the input. In all tests, it was shown that the use of the Final Value Theorem presents advantages compared to the use of algorithms without restrictions. Finally, it was revealed that the Gray Wolf Algorithm has a better performance for parametric estimation compared to the Jaya algorithm with an error up to 50% lower.
1 January 2017 in Programming and Computer Software
We present a method for measuring similarity between source codes. We approach this task from the machine learning perspective using character and word n-grams as features and examining different machine learning algorithms. Furthermore, we explore the contribution of the latent semantic analysis in this task. We developed a corpus in order to evaluate the proposed approach. The corpus consists of around 10,000 source codes written in the Karel programming language to solve 100 different tasks. The results show that the highest classification accuracy is achieved when using Support Vector Machines classifier, applying the latent semantic analysis, and selecting as features trigrams of words.
In the present work, a neuronal dynamic response prediction system is shown to estimate the response of multiple systems remotely without sensors. For this, a set of Neural Networks and the response to the step of a stable system is used. Six basic characteristics of the dynamic response were extracted and used to calculate a Transfer Function equivalent to the dynamic model. A database with 1,500,000 data points was created to train the network system with the basic characteristics of the dynamic response and the Transfer Function that causes it. The contribution of this work lies in the use of Neural Network systems to estimate the behavior of any stable system, which has multiple advantages compared to typical linear regression techniques since, although the training process is offline, the estimation can perform in real time. The results show an average 2% MSE error for the set of networks. In addition, the system was tested with physical systems to observe the performance with practical examples, achieving a precise estimation of the output with an error of less than 1% for simulated systems and high performance in real signals with the typical noise associated due to the acquisition system.
The peak demand or demand limit control is an important part of the actions that industries carry out to optimize their energy consumption and reduce the costs related to their electricity billing. Prioritized switching of multiple appliances is often needed in order to reduce demand and energy consumption during peak load periods. The present article describes a peak load limitation algorithm that estimates the optimal disconnection time for one or more electrical loads before the electric demand exceeds a preset limit. This algorithm uses parametric and variable load factors that vary dynamically depending on what loads are present at a given time. For its validation, a software-in-the-loop testbed was designed and developed, in which multiple electrical loads were simulated via LabVIEW software and connected to a PLC controller emulated through CODESYS software. In this environment, several test configurations were executed and evaluated to study the influence of variables such as the nominal power and the disconnection priority of loads in the algorithm output. The results showed that the control algorithm is effective for peak load limitation, the maximum demand value reached during simulations tests did not exceed the preset demand limit at any time interval. The performance of the algorithm could be improved when prioritizing the shutdown of loads with higher nominal power or when increasing the anticipation time used for the disconnection of the controllable loads.
This study presents an integrated engineering methodology aligned with the planning phase of the ISO 50001:2018 (Energy Management Systems—Requirements with Guidance for Use. International Organization for Standardization (ISO): Geneva, Switzerland, 2018) energy management standard for the design, sizing, and assessment of a solar thermal system applied to domestic hot water production in a medium-scale hotel building. The proposed framework focuses on the energy review stage of ISO 50001, incorporating site-specific climatic assessment, spatial layout optimization, structural feasibility analysis, and energy performance evaluation to support informed technology selection and system viability. Thermal performance is assessed using real operational data from the case study, complemented by a data-driven multivariable regression-based energy performance indicator (EnPI) that relates electricity consumption to cooling degree days and room occupancy. This regression model, developed in accordance with ISO 50001 recommendations, enables transparent monitoring of energy performance under real operating conditions without relying on black-box predictive techniques. Material selection criteria for absorber plates, heat-transfer components, transparent covers, and insulation layers are discussed to support both initial efficiency and performance stability under site-specific climatic conditions. In addition, an indicative and qualitative analysis of material-dependent performance evolution is introduced to support comparative decision-making, without implying quantitative lifetime prediction. Structural feasibility of the collector support system is examined through finite-element simulations under combined gravitational and wind loads, providing illustrative verification of stress distribution under representative operating conditions. The installed system delivers an annual thermal energy contribution of 8468 kWh, resulting in an estimated reduction of 7.79 t of CO2 emissions per year. Economic indicators suggest a short payback period and a favorable internal rate of return, which should be interpreted as order-of-magnitude estimates within the planning scope of the methodology. Overall, the proposed methodology provides a replicable and multidisciplinary planning-phase framework aligned with ISO 50001 for the design and assessment of solar thermal systems in medium-scale buildings under real operating conditions.