Bone specimens obtained for biomechanical experiments are fresh-frozen for storage to slow down tissue degradation and autolysis in long-term storage. Alternatively, due to infectious risks related to the fresh tissues, fixative agents are commonly used. However, fixatives will likely change the mechanical properties of bone. Existing studies on this issue gave controversial results that are hardly comparable due to a variety of measurement approaches. For this reason, the influence of ethanol and a formalin-based fixative agent was evaluated on the mechanical properties of human cortical bone specimens by means of four-point-bending tests. 127 prismatic specimens with rectangular cross sections (2.5 x 2.5 x 20 mm3) were obtained from different regions of two fresh human femora (medial, lateral, dorsal, ventral). Specimens were either fixed in ethanol or in a mixed formalin solution or frozen following a given scheme. After two weeks of storage the samples were re-hydrated in isotonic saline and subsequently tested mechanically. The elastic bending modulus and ultimate bending strength were computed considering the actual dimensions of each specific specimen. For statistical analysis a one-way-ANOVA and an LSD post-hoc-test were performed. For ultimate bending strength no significant differences due to formalin or ethanol fixation, as compared to unfixed-fresh bone specimens could be found. And only for few cases significant differences in elastic bending modulus were observed when the two bones were evaluated separately. Since more differences of significant level due to the anatomical region of the samples were determined, the original location seems to have more influence on the evaluated mechanical properties than the method of (chemical) fixation. Consequently, ethanol and the mixed formalin solution can be recommended as a fixation agent for samples in biomechanical testing, if these samples are rinsed in isotonic saline prior to static mechanical testing.
Ceramics are a very popular material in dental implant technology due to their tribological properties, their biocompatibility and their esthetic appearance. However, their natural surface structure lacks the ability of proper osseointegration, which constitutes a crucial process for the stability and, thus, the functionality of a bone implant. We investigated the application of a glass solder matrix in three configurations—consisting mainly of SiO2, Al2O3, K2O and Na2O to TZP-A ceramic specimens. The corresponding adhesive strength and surface roughness of the coatings on ceramic specimens have been analyzed. Thereby, high adhesive strength (70.3 ± 7.9 MPa) was found for the three different coatings. The obtained roughness (Rz) amounted to 18.24 ± 2.48 µm in average, with significant differences between the glass solder configurations. Furthermore, one configuration was also tested after additional etching which did not lead to significant increase of surface roughness (19.37 ± 1.04 µm) or adhesive strength (57.2 ± 5.8 MPa). In conclusion, coating with glass solder matrix seems to be a promising surface modification technique that may enable direct insertion of ceramic implants in dental and orthopaedic surgery.
Both titanium and ceramic materials provide specific advantages in dental implant technology. However, some problems, like hypersensitivity reactions, corrosion and mechanical failure, have been reported. Therefore, the combining of both materials to take advantage of their pros, while eliminating their respective cons, would be desirable. Hence, we introduced a new technique to bond titanium and ceramic materials by means of a silica-based glass ceramic solder. Cylindrical compound samples (Ø10 mm × 56 mm) made of alumina toughened zirconia (ATZ), as well as titanium grade 5, were bonded by glass solder on their end faces. As a control, a two-component adhesive glue was utilized. The samples were investigated without further treatment, after 30 and 90 days of storage in distilled water at room temperature, and after aging. All samples were subjected to quasi-static four-point-bending tests. We found that the glass solder bonding provided significantly higher bending strength than adhesive glue bonding. In contrast to the glued samples, the bending strength of the soldered samples remained unaltered by the storage and aging treatments. Scanning electron microscopy (SEM) and energy-dispersive X-ray (EDX) analyses confirmed the presence of a stable solder-ceramic interface. Therefore, the glass solder technique represents a promising method for optimizing dental and orthopedic implant bondings.