Tao Meng

Tao Meng


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2020 in IEEE Access
Verified
Journal Article
Open access
HSHuichao Shi
Huichao Shi
XKXirui Kang
Xirui Kang
SHShuman He
Shuman He
TMTao Meng
Tao Meng
For a clamp-on ultrasonic flowmeter based on transit-time differential method, the flow rate calculation model with flow velocity correction is established and verified by experiments carried out in a flow standard facility. Based on established flow rate calculation model, a systematic methodology incorporating the parametric uncertainty distribution is proposed to analyze the influences of multiple parameters with uncertainty on measurement error by establishing the sample-based stochastic model. Monte Carlo sampling (MCS) method is used to randomly select the value of each parameter from its prescribed Gaussian distribution and then combining them together as one sample, and the number of selected samples is determined by conducting stochastic convergence analysis of mean value and the standard deviation of input and output parameters. And finally the influence degrees of multiple parameters are analyzed and compared quantitatively on the same dimension to find out which parameters are influential and which are negligible. The results reveal the different influences of multiple parameters with uncertainty, which can be used as reference for performance improvement and measuring error analysis of the clamp-on ultrasonic flowmeter in industrial local measurement.

1 May 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
TMTao Meng
Tao Meng
SFShangchun Fan
Shangchun Fan
CWChi Wang
Chi Wang
HSHuichao Shi
Huichao Shi
The relationship between flow fluctuation and pressure in a flow facility is studied theoretically and experimentally in this paper, and a method for measuring the flow fluctuation is proposed. According to the synchronicity of pressure and flow fluctuation, the amplitude of the flow fluctuation is calculated using the pressure measured in the flow facility and measurement of the flow fluctuation in a wide range of frequency is realized. Based on the method proposed, uncertainty analysis is used to evaluate the influences of different parameters on the flow fluctuation by the help of a sample-based stochastic model established and the parameters that have great influence are found, which can be a reference for the optimization design and the stability improvement of the flow facility.

1 January 2019 in Journal of Thermal Science and Technology
Verified
Journal Article
Open access
PDF file
TMTao Meng
Tao Meng
XYXiao Yan
Xiao Yan
FZFulong Zhao
Fulong Zhao
HBHanliang Bo
Hanliang Bo
CZChen Zeng
Chen Zeng
STSichao Tan
Sichao Tan
The fuel oil atomization is closely related to the combustion performance of the fuel in the internal combustion engine. However, during the oil atomization, the fast evaporating and moving oil droplets interact strongly with the surrounding gas, posing challenges towards the precise simulation of the combustion process. To precisely capture the interactions between fuel droplets and the surrounding gas, a new multi-droplets motion and evaporation model is deduced by introducing the local parameters surrounding the fuel droplets. The proposed model is validated comparing the simulation results against the experimental data of the containment spray process. Subsequently, the present model is adopted to simulate the fuel spray process in the typical constant volume bomb. The parameters evolution is presented during the course of the spray such as the gas temperature, droplet temperature, evaporating rate, velocity, radii variation, vapor concentration and air-fuel ratio. The analysis of the spray performance is conducted and the superiority of the new model is also discussed. The simulation analysis reveals that the spray droplets interact strongly with the surrounding gas; the developed droplet motion and evaporation model is advantageous in the simulation of the dense multi-droplets spray process.

1 January 2022 in Metrologia
Verified
Journal Article
Closed access
NFN Furuichi
N Furuichi
RAR Arias
R Arias
CYC-T Yang
C-T Yang
SCSejong Chun
Sejong Chun
TMTao Meng
Tao Meng
FSF M Smits
F M Smits
Main text: The objective of the Key Comparison CCM.FF-K1.2015 for water flow measurement was to support and prove the Calibration and Measurement Capabilities (CMC) of the participating NMIs of Japan (AIST), Mexico (CENAM), Chinese Taipei (ITRI), Korea (KRISS), P.R. China (NIM), Germany (PTB), USA (NIST), Sweden (RISE), UK (NEL), Turkey (TUBITAK UME) and Netherlands (VSL). The comparison was organized as a round robin, started in December 2015 at PTB and finished in April 2018, also at PTB. As pilot laboratory, the national metrology institute of Germany (PTB) organised the comparison. A combined setup of a turbine meter and Coriolis meter was used as a transfer standard (TS), which was provided by the pilot laboratory. The nominal calibration conditions of the KC were defined within the flow range between 30 m3/h and 200 m3/h, 20 °C fluid temperature and 3 bar line pressure. A special focus of the comparison was to estimate the uncertainties of the transfer standard (u TS). Both transfer meters were subjected to extensive characterization measurements at pilot laboratory, with the following investigated parameters: fluid temperature, line pressure, repeatability, flow stability, meter sensitivity to varying inflow conditions and hysteresis effects. For turbine meter, all labs passed the E N criteria of ≤ 1.20. The calibrations of the turbine meter were strongly affected by the presence of the large values for u TS with > 0.12 % k =1) which were mainly caused by the meter sensitivity to disturbed inflow conditions. This effect led to inconclusive calibration results for all laboratories. The evaluation criteria u comp/u base exceeded the critical value of 2.00. Finally, the turbine meter was not suitable for a confirmation of all submitted CMC values. For Coriolis meter, all labs passed the E N criteria of ≤ 1.20. In contrast to turbine meter, the evaluation criteria u comp/u base exceeded the critical value of 2.00 for one laboratory, only. The maximum uncertainty u TS of Coriolis meter was estimated with 0.022 % (k =1). In summary, the comparison was successfully finished for a confirmation of the submitted CMC values, related to mass calibrations. For volume related CMCs this comparison was not suitable. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

15 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
TMTao Meng
Tao Meng
焕魏焕昌 魏
焕昌 魏
FGFeng Gao
Feng Gao
HSHuichao Shi
Huichao Shi
In order to accurately evaluate the flow stability of the flow standard facility, the flow fluctuation in the standard facility needs to be accurately measured. However, the flow fluctuation signal is always superimposed with the fluctuation signal of the measuring flowmeter or measurement system (mainly noise), which leads to inaccurate measurement of the flow fluctuation and even an unreliable evaluation result of the flow stability. In addition, when there are multiple fluctuation sources, flow fluctuations with different frequencies are superimposed together, which is extremely unfavorable for evaluating the impact of flow fluctuation with different single frequencies. In this paper, a new measuring method was proposed to obtain the fluctuation signal and the flow fluctuation based on singular value decomposition (SVD). Simulation experiments on the fluctuation signal (single frequency and multiple frequencies) under different levels of noise were conducted, and simulation results showed that the proposed method could accurately obtain the fluctuation signal and the flow fluctuation, even under high noise. Finally, an experimental platform was set-up based on a water flow standard facility and a flow fluctuation generator, and experiments on the output signal of a venturi flowmeter were carried out. The experiment results showed that the proposed method could effectively obtain the fluctuation signal and accurately measure the flow fluctuation.

1 August 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
HSHuichao Shi
Huichao Shi
XKXirui Kang
Xirui Kang
LNLi Niu
Li Niu
TMTao Meng
Tao Meng
SFShangchun Fan
Shangchun Fan
The characteristic of weak resonant signal output by an electrothermally excited microresonator is analyzed, and the principal component analysis (PCA) method is proposed and applied in the resonant frequency detection of the output weak signal by separating the noises. Simulation on weak resonant signals under different levels of noises and different quality factors of the resonator was conducted after the influence of the data selection window width and the principal component number on detection results was analyzed. Finally, the experiment platform was built, and the output signal of the sensor sample was used to verify the detection effect of the proposed PCA method. Simulation and experiment results show that the proposed PCA method could accurately obtain the resonant frequency compared with the resonant frequency obtained by the smoothing filter and Lorentzian fitting method.