Maximilian Modelhart

Dr. Maximilian Modelhart

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2026 in Royal Society Open Science
Verified
Journal Article
Open access
EHEva C. Herbst
Eva C. Herbst
HHHeath B. Henninger
Heath B. Henninger
FSFlavia Stettler
Flavia Stettler
MMMaximilian Modelhart
Maximilian Modelhart
MTMatteo Tanadini
Matteo Tanadini
PMPhilipp Moroder
Philipp Moroder
The aims of this study were to (i) quantify glenohumeral (GH) joint translations in healthy shoulders, (ii) assess subject-specific variability in GH translations, (iii) determine whether bony joint geometry (glenoid height, width, retroversion, inclination, GH asphericity and congruence), upright scapular posture, motion and handheld load affect translation magnitude and (iv) analyse the position of the humeral head centre (HHC) starting point relative to different glenoid centre definitions. We measured translations of the HHC relative to the glenoid axes in 19 healthy subjects during five arm motions. Mean 3D, superoinferior (SI), anteroposterior (AP), and mediolateral (ML) translation magnitudes were 14.7% of glenoid height, 9.5% of glenoid height, 15.4% of glenoid width, and 7.4% of glenoid height, respectively. Glenoid height affected 3D and SI translation magnitude inclination angle, glenoid asphericity and scapular tilt affected 3D and AP translation magnitudes and motion affected 3D, AP and SI translation magnitudes (p≤ 0.05, but effect sizes are small and large confidence intervals warrant further experiments). The starting point of the HHC was closer to the glenoid geometric mean than to the inferior glenoid circle center, which may be useful clinically when attempting to restore healthy HHC positioning.

24 June 2026 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Open access
ASAbdelkader Shekhbihi
Abdelkader Shekhbihi
PRPatric Raiss
Patric Raiss
MMMaximilian Modelhart
Maximilian Modelhart
LRLisa-Marie Randlkofer
Lisa-Marie Randlkofer
EHEva C. Herbst
Eva C. Herbst
PMPhilipp Moroder
Philipp Moroder
In reverse total shoulder arthroplasty (rTSA), glenoid component inclination critically influences complications and implant performance. Current literature predominantly advocates for neutral or 0° inclination referenced to the supraspinatus fossa in order to avoid superior tilt which may lead to loosening. However, the influence of resting scapular rotation (RSR) on the effectively obtained inclination relative to the global reference system (gravity) remains poorly defined. This study aims to address this gap by evaluating the impact of RSR on global glenoid component inclination following rTSA. This retrospective cohort included 93 consecutive patients who underwent rTSA with 3D preoperative planning and patient-specific instrumentation (PSI) for baseplate placement targeting 0° inclination. Standardized pre- and postoperative true anteroposterior radiographs were obtained with a vertical plumb line aligned to gravity. Measured parameters included scapular rotation angle (SRA), humeral abduction resting angle (HARA), scapulohumeral abduction resting angle (S-HARA), glenoid inclination angle (GIA), global glenoid inclination (GGI), and arthroplasty scapulohumeral abduction resting angle (AS-HARA). Interrater reliability was assessed using intraclass correlation coefficients (ICC). The effect of preoperative RSR on postoperative GGI was evaluated. Correlations among radiographic parameters and associations with clinical outcomes at 9 and 26 weeks were analyzed using multiple regression. Interrater reliability for the measured parameters was excellent (ICC=0.953-0.989). SRA varied widely from 14° upward rotation to 42° downward rotation with a mean of -15±9°. Three reproducible SRA types were identified, which remained mostly constant postoperatively. Despite a targeted glenoid inclination angle of 0°, GGI differed significantly with a mean of -18±10° and a range from 1 to -53° (p<0.0001) and demonstrated a strong correlation with SRA (r=0.77). Preoperatively, S-HARA averaged 113±10° and HARA 7±8°; postoperatively, S-HARA 117±10°, HARA 7±8°, and AS-HARA 116±10°. At 9 weeks, higher postoperative AS-HARA and S-HARA were associated with better ASES Index Scores, whereas by 26 weeks patients had recovered regardless. Preoperative RSR varied substantially across the cohort. Consequently, the effective postoperative global glenoid component inclination ranged from downward to superior inclination depending on the scapula rotation angle, despite targeted glenoid inclination angle of 0° executed with PSI. Therefore, accounting for scapula rotation in terms of the global glenoid inclination when planning the glenoid component inclination seems warranted. The consistency of SRA before versus after rTSA allows its incorporation into personalized planning to avoid superior inclination in the global reference system, which may increase shear forces on the glenoid component and lead to a slower recovery.

17 September 2025 in JSES International
Verified
Journal Article
Open access
MMMaximilian Modelhart
Maximilian Modelhart
EHEva C. Herbst
Eva C. Herbst
AKAlexander M.H. Kunde
Alexander M.H. Kunde
ASAbdelkader Shekhbihi
Abdelkader Shekhbihi
THThomas Hoffelner
Thomas Hoffelner
PMPhilipp Moroder
Philipp Moroder
The labral complex plays a crucial role in shaping the glenoid fossa morphology, thereby enhancing passive joint stability. This study aimed to investigate the influence of the labrum on glenoid inclination, a key determinant for load distribution within the joint. In addition, the labral influence on glenoid concavity depth and radius of curvature in the supero-inferior plane was evaluated. Forty-three patients (mean age: 42 years [range 21-64 years]; 35 males, 8 females) with acromioclavicular (AC)-joint dislocation and no glenohumeral pathologies, who received a full series of magnetic resonance imaging or magnetic resonance arthrography, were retrospectively included. For each patient, the glenoid surface inclination, concavity depth, and radius of curvature was measured and compared to their respective values of the bony glenoid. In addition, the bony humeral head radius was measured to evaluate the influence of the labrum on joint congruency. Paired t-tests were used to assess the differences between bony and glenoid surface inclination and concavity depth. Repeated measures analysis of variance and pairwise comparisons were made to compare radius of curvature measurements. The correlation between the bony glenoid inclination and its difference to glenoid surface inclination, as well as between the bony glenoid radius and its difference to glenoid surface radius, was analyzed. The bony glenoid inclination measured 7.1° ( ± 4.1° standard deviation [SD]), the glenoid surface inclination 1.6° ( ± 3.2° SD); the bony glenoid concavity depth measured 4.0 mm ( ± 0.8 mm SD), the glenoid surface concavity depth 7.1 mm ( ± 0.9 mm SD). The bony glenoid radius of curvature measured 33.4 mm ( ± 3.3 mm SD), the glenoid surface radius 25 mm ( ± 2.1 mm SD) and the humeral head radius 24.1 mm ( ± 1.7 mm SD). The labrum significantly decreased the glenoid fossa inclination by 5.5° (P < .001), significantly decreased the glenoid fossa radius by 8.4 mm (P < .001) and significantly increased the concavity depth by 3.2 mm (P < .001). There was a positive correlation between the bony glenoid inclination and its respective difference to the glenoid surface inclination (r = 0.71, P < .001). Also, there was a positive correlation between bony glenoid radius of curvature and its respective difference to the glenoid surface radius (r = 0.77, P < .001). The labral complex decreases glenoid inclination and increases joint concavity and congruency in the supero-inferior plane. Differences between bony and surface glenoid measures were higher in individuals with increased superior bony inclination and larger bony radii, suggesting a compensatory role to the labrum for the underlying bony morphology.

27 July 2026 in JSES International
Verified
Journal Article
Open access
MMMaximilian Modelhart
Maximilian Modelhart
EHEva C. Herbst
Eva C. Herbst
ASAbdelkader Shekhbihi
Abdelkader Shekhbihi
SBStefan Bauer
Stefan Bauer
JWJean-David Werthel
Jean-David Werthel
PMPhilipp Moroder
Philipp Moroder

26 December 2025 in JSES International
Verified
Journal Article
Open access
ASAbdelkader Shekhbihi
Abdelkader Shekhbihi
AAAbdelhady Abdalla
Abdelhady Abdalla
MMMaximilian Modelhart
Maximilian Modelhart
EHEva C. Herbst
Eva C. Herbst
PRPatric Raiss
Patric Raiss
PMPhilipp Moroder
Philipp Moroder
Anatomic total shoulder arthroplasty (aTSA) is a viable option for select patients with favorable long-term outcomes. However, instability with static decentering and eccentric wear remains a concern. An important factor contributing to the stability of aTSA is the liner-generated stability ratio, constituted by jump-height and radius of curvature. This study aimed to measure jump height and radius of curvature as well as to assess the liner stability ratio (LSR) of various aTSA glenoid components, enabling comparisons of the degree of constraint between implant systems. Using manufacturer-independent planning software, glenoid component height, jump height, and radius of curvature in the longitudinal and transverse axes were measured across 28 aTSA systems from 14 companies by two independent raters, with transverse measurements taken at the broadest diameter (t1) and at the corresponding midpoint level of the longitudinal axis (t2); data were validated by comparison with manufacturer-provided specifications. LSR were calculated using a previously validated mathematical formula. The inter-rater reliability was determined using the intraclass correlation coefficient. Visual diagrams illustrated the relationship between glenoid component height, jump height, and LSR across glenoid components of various aTSA designs. The mean glenoid component height was 32.8 ± 4.9 mm (range, 22.3-43.8 mm), while the mean jump height and radius of curvature were 5.1 ± 1.5 mm (range, 2.4-9.9 mm) and 29.7 ± 3.6 mm (range, 21.7-38.1 mm) in the longitudinal axis, 2.7 ± 0.7 mm (range, 1.5-5.1 mm) and 29.5 ± 3.9 mm (range, 19.9-38.5 mm) in the transversal axis (t1), and 2.6 ± 0.7 mm (range, 1.3-4.7 mm) and 29.7 ± 3.9 mm (range, 20.1-39.7 mm) for t2, respectively. Calculated LSR ranged from 39% to 115% (68% ± 15%) for the longitudinal axis, 31% to 71% (47% ± 8%) for t1, and from 28% to 65% (45% ± 8%) for t2, across available aTSA systems. Manufacturer-provided specifications from two companies showed high concordance with the obtained measurements. Regarding LSR consistency, only 2 systems were consistent (≤5% variation) in both axes. Slight inconsistencies (>5-10%) appeared in 3 systems longitudinally and 5 transversely, while most showed >10% variation across sizes. Inter-rater reliability demonstrated near-perfect agreement between testers. This study highlights significant variability in the LSR across different glenoid components of aTSA systems, with inconsistencies often even observed within the same system. While the direct clinical impact remains uncertain, the LSR of the glenoid component in aTSA may have an effect on aTSA stability, component wear and loosening attributed to the rocking horse phenomenon. Further research is needed to clarify the biomechanical consequences of LSR variations on aTSA.

14 July 2026 in JBMR Plus
Verified
Journal Article
Open access
MMMaximilian Modelhart
Maximilian Modelhart
DADennis C Agbanyim
Dennis C Agbanyim
DCDavide Cester
Davide Cester
PMPhilipp Moroder
Philipp Moroder
SFStephen John Ferguson
Stephen John Ferguson
EHEva C Herbst
Eva C Herbst
Evaluation of glenoid trabecular bone quality is important for patients undergoing shoulder arthroplasty, as the density of the glenoid bone is likely to influence implant stability. Routine CT scans show promise for quantitative bone density assessments, but CT-based calibration typically involves scanning a phantom, which limits its application in clinical practice and in retrospective research studies. Here, we developed and validated a phantomless BMD measurement technique to evaluate glenoid trabecular bone density (mg/cc) using clinical shoulder CT scans of 88 patients (48 males, 40 females; mean age: 53 years). Air, fat, and muscle tissue were used as internal density references to develop patient-specific calibration functions for glenoid BMD estimation. The phantomless calibration was validated by comparison with an asynchronous phantom-based calibration using the European Spine Phantom. A Bland-Altman analysis yielded a mean difference of 0.37 mg/cc (95% CI: [–1.39, 2.14] mg/cc) between the two methods. Further improvement in internal calibration accuracy was achieved by implementing an age-stratified approach (two age groups; cut-off 55 years) to account for age-related declines in muscle density. With age stratification of reference tissue densities, the mean difference between internal and phantom-based calibration was reduced to 0.20 mg/cc (95% CI: [–1.38, 1.78] mg/cc). The proposed phantomless calibration approach provides a robust and clinically feasible method to evaluate glenoid trabecular bone density in both research and clinical applications. Moreover, the results highlight the importance of considering patient-specific variations in shoulder muscle density to ensure accurate internal calibration.