Offshore wind turbines are supported by various foundations, each with its considerations in design and construction. Gravity, monopile, and suction bucket foundations encounter geotechnical issues, while jacket and tripod foundations face fatigue problems. Considering this, a gravity foundation based on a steel skirt was developed, and a monopile foundation was analyzed for Pile-Soil Interaction using the p–y curve and 3D finite element method (3D FEM). In addition, for suction bucket foundations, the effects of lateral and vertical loads were analyzed using 3D FEM and centrifuge tests. Fatigue analysis for jacket and tripod foundations was conducted using a hotspot stress approach. Some hybrid foundations and shape optimization techniques that change the shape to complement the problems of each foundation described above were assessed. Hybrid foundations could increase lateral resistance compared to existing foundations because of the combined appendages, and optimization techniques could reduce costs by maximizing the efficiency of the structure or by reducing costs and weight. This paper presents the characteristics and research directions of the foundation through various studies on the foundation. In addition, the optimal design method is presented by explaining the problems of the foundation and suggesting ways to supplement them.
Partial discharge (PD) is a critical indicator of insulation degradation in high-voltage DC systems, necessitating accurate diagnosis to ensure long-term reliability. Conventional AC-based diagnostic methods, such as phase-resolved partial discharge analysis (PRPDA), are ineffective under DC conditions, emphasizing the need for waveform-based analysis. This study presents a novel clustering framework for DC PD pulses, leveraging multi-level wavelet decomposition and statistical feature extraction. Each signal is decomposed into multiple frequency bands, and 70 distinctive waveform features are extracted from each pulse. To mitigate feature redundancy and enhance clustering performance, principal component analysis (PCA) is employed for dimensionality reduction. Experimental data were obtained from multiple defect types and measurement distances using a 22.9 kV cross-linked polyethylene (XLPE) cable system. The proposed method significantly outperformed conventional time-frequency (T-F) mapping techniques, particularly in scenarios involving signal attenuation and mixed noise. Propagation-induced distortion was effectively addressed through multi-resolution analysis. In addition, field noise sources such as HVDC converter switching transients and fluorescent lamp emissions were included to assess robustness. The results confirmed the framework’s capability to distinguish between multiple PD types and noise sources, even in challenging environments. Furthermore, optimal mother wavelet selection and correlation-based feature analysis contributed to improved clustering resolution. This framework supports robust PD classification in practical HVDC diagnostics. The framework can contribute to the development of real-time autonomous monitoring systems for HVDC infrastructure. Future research will explore incorporating temporal deep learning architectures for automated PD-type recognition based on clustered data.
The growing demand for direct current transmission emphasizes the need for advanced insulation suitable for high-capacity, long-distance applications. Thermoplastics, especially polypropylene, offer several advantages over conventional materials like XLPE (cross-linked polyethylene) and EPR (ethylene propylene rubber), including higher thermal stability, recyclability, and reduced space charge accumulation. However, due to the inherent rigidity and limited flexibility of PP, its mechanical aging becomes a critical factor in assessing its long-term reliability as a cable insulation. In this study, mechanical aging characteristics, specifically declines in tensile strength and elongation, were selected as key indicators of insulation aging. Accelerated aging tests were conducted at 90 °C, 110 °C, and 130 °C for up to 5000 h. The experimental data were fitted to exponential models to derive aging coefficients, which formed the basis for the proposed aging model and the ACI (aging condition index). The ACI enables quantitative assessment of the current insulation condition and estimation of the remaining lifetime until a predefined threshold (e.g., ACI = 0.5) is reached. These findings contribute to the development of condition-based maintenance strategies and long-term asset management for power cables, offering practical insights for improving the reliability of future power grid systems.
Biofouling on offshore wind farm substructures threatens operational reliability and raises maintenance demands, underscoring the need for effective antifouling strategies. This study presents a 27-month evaluation of fouling development on a conventional non-antifouling coating and self-polishing copolymer (SPC) systems at a South Korean offshore wind farm. Biofouling coverage was assessed through long-term image analysis, and surface energy was characterized via contact angle measurements. Species analyses identified successional communities dominated by barnacles, coralline algae, and bryozoa. The conventional coating showed rapid colonization, exceeding 90% coverage within 10 months, whereas the SPC systems exhibited superior performance by suppressing settlement, though their effectiveness declined over time. Quantitative analysis revealed a clear relationship between higher surface energy and increased fouling rates, highlighting material properties as a key factor in colonization. This study provides one of the first long-term quantitative datasets from South Korean waters, advancing understanding of biofouling dynamics and informing antifouling strategies for offshore wind infrastructure.
31 December 2025 in Journal of Ocean Engineering and Technology
Offshore demonstration of submarine cables is conducted under uncertain marine conditions and complex offshore operations, requiring a systematic risk assessment. This study divides the demonstration process into four phases (loading/unloading, transport, installation/decommissioning, and offshore testing/maintenance) and identifies potential hazards through expert workshops. Hazard items were first identified using a checklist-based review and a task-based hazard identification (HAZID) workshop, in which offshore work procedures were decomposed into step-by-step tasks and potential accident scenarios were derived. Based on these identified hazards, the analytic hierarchy process (AHP) was applied to evaluate the relative risk level of each phase, and a risk matrix (Likelihood–Severity, LS) was used to assess the risk level of individual hazards. The AHP results indicate that the installation/decommissioning phase poses the highest risk (36.9%), followed by offshore testing/maintenance (29.1%), transport (22.6%), and loading/unloading (11.4%). In the LS analysis, cable damage during installation/decommissioning and lightning strikes during offshore testing/maintenance were evaluated as the highest-grade hazards. These findings provide a risk profile that spans the entire offshore demonstration cycle of submarine cables and offer a basis for prioritizing safety management, allocating resources, and planning operational procedures.