Byungbae Park

Mr. Byungbae Park


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2020 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
SLSeung Won Lee
Seung Won Lee
HKHae-Jong Kim
Hae-Jong Kim
BPByungbae Park
Byungbae Park
HRHee-Suk Ryoo
Hee-Suk Ryoo
JCJeon-Wook Cho
Jeon-Wook Cho
JLJang-Seob Lim
Jang-Seob Lim

11 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
SYSung-Ho Yoon
Sung-Ho Yoon
IKIk-Su Kwon
Ik-Su Kwon
JLJinseok LIM
Jinseok LIM
BPByungbae Park
Byungbae Park
SLSeung Won Lee
Seung Won Lee
HKHae-Jong Kim
Hae-Jong Kim
Partial discharge (PD) is a critical indicator of insulation degradation in high-voltage DC systems, necessitating accurate diagnosis to ensure long-term reliability. Conventional AC-based diagnostic methods, such as phase-resolved partial discharge analysis (PRPDA), are ineffective under DC conditions, emphasizing the need for waveform-based analysis. This study presents a novel clustering framework for DC PD pulses, leveraging multi-level wavelet decomposition and statistical feature extraction. Each signal is decomposed into multiple frequency bands, and 70 distinctive waveform features are extracted from each pulse. To mitigate feature redundancy and enhance clustering performance, principal component analysis (PCA) is employed for dimensionality reduction. Experimental data were obtained from multiple defect types and measurement distances using a 22.9 kV cross-linked polyethylene (XLPE) cable system. The proposed method significantly outperformed conventional time-frequency (T-F) mapping techniques, particularly in scenarios involving signal attenuation and mixed noise. Propagation-induced distortion was effectively addressed through multi-resolution analysis. In addition, field noise sources such as HVDC converter switching transients and fluorescent lamp emissions were included to assess robustness. The results confirmed the framework’s capability to distinguish between multiple PD types and noise sources, even in challenging environments. Furthermore, optimal mother wavelet selection and correlation-based feature analysis contributed to improved clustering resolution. This framework supports robust PD classification in practical HVDC diagnostics. The framework can contribute to the development of real-time autonomous monitoring systems for HVDC infrastructure. Future research will explore incorporating temporal deep learning architectures for automated PD-type recognition based on clustered data.

16 February 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
JKJunil Kim
Junil Kim
MSMyung-Hwan Sohn
Myung-Hwan Sohn
JCJeonwook Cho
Jeonwook Cho
SKSung-Kyu Kim
Sung-Kyu Kim
BPByungbae Park
Byungbae Park
SKSeokho Kim
Seokho Kim
The rare isotope accelerator complex for online experiments (RAON) is a heavy-ion accelerator equipped with an in-flight fragment separator (IF) system and isotope separation online technique in South Korea. Six quadrupole and a sextupole high-temperature superconducting (HTS) magnets are installed in the hot cell of the IF system, which is a high radiation region, to arrange the ion beams and correct the chromatic aberrations of the ion beams. The magnets are developed and installed for RAON at the Institute for Basic Science (IBS), South Korea. Superconducting magnet systems should be capable of a stable operation against high radiation heating and thermally and electromagnetically robust in the intense radioactive hot cell region. In this paper, we describe the design, fabrication, and evaluation of a sextupole HTS magnet. Electromagnetic designs are conducted considering the position of the HTS magnets and the angle of the yoke pole tip et al. The required design specifications are proposed as a part of RAON of IBS considering the following electromagnetic performance: 1) a magnetic field gradient of $ \geq $ 3.9 T/m 2 , 2) magnetic field uniformity of $ < $ 0.5%, 3) effective length of 450 ± 1 mm, and 4) operating temperature of ∼ 45 K.

21 July 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SLSeung Won Lee
Seung Won Lee
IKIk-Su Kwon
Ik-Su Kwon
BPByungbae Park
Byungbae Park
SYSung-Ho Yoon
Sung-Ho Yoon
DKDONGEUN KIM
DONGEUN KIM
HKHae-Jong Kim
Hae-Jong Kim
The growing demand for direct current transmission emphasizes the need for advanced insulation suitable for high-capacity, long-distance applications. Thermoplastics, especially polypropylene, offer several advantages over conventional materials like XLPE (cross-linked polyethylene) and EPR (ethylene propylene rubber), including higher thermal stability, recyclability, and reduced space charge accumulation. However, due to the inherent rigidity and limited flexibility of PP, its mechanical aging becomes a critical factor in assessing its long-term reliability as a cable insulation. In this study, mechanical aging characteristics, specifically declines in tensile strength and elongation, were selected as key indicators of insulation aging. Accelerated aging tests were conducted at 90 °C, 110 °C, and 130 °C for up to 5000 h. The experimental data were fitted to exponential models to derive aging coefficients, which formed the basis for the proposed aging model and the ACI (aging condition index). The ACI enables quantitative assessment of the current insulation condition and estimation of the remaining lifetime until a predefined threshold (e.g., ACI = 0.5) is reached. These findings contribute to the development of condition-based maintenance strategies and long-term asset management for power cables, offering practical insights for improving the reliability of future power grid systems.

22 June 2026 in Energies
Verified
Journal Article
Open access
PDF file
BPByungbae Park
Byungbae Park
IKIk-Su Kwon
Ik-Su Kwon
JCJeon-Wook Cho
Jeon-Wook Cho
BLBang-Wook Lee
Bang-Wook Lee
Reliable insulation design for LNG feedthroughs requires fundamental dielectric breakdown data obtained under cryogenic LNG conditions. However, such data remain scarce owing to the explosion-proof requirements imposed by the flammable nature of LNG. Furthermore, the influence of phase differences between LNG and NG on creepage dielectric breakdown behavior along insulation surfaces has received little attention. In this study, an explosion-proof cryostat and test facility compliant with the IEC 60079 series of standards were developed, and dielectric breakdown tests were conducted over a range of electrode gap distances and pressures. Two electrode configurations were employed: rod–plate electrodes for dielectric breakdown characterization in LN2 and LNG, and creepage electrodes for surface dielectric breakdown evaluation in NG and LNG. Experimental results show that LNG requires approximately 1–2 bar of additional operating pressure above that of LN2 to achieve equivalent dielectric strength. Moreover, LNG exhibited higher creepage dielectric breakdown voltages than NG under all test conditions, with the difference becoming more pronounced as pressure and creepage distance increased. Post-breakdown surface analysis revealed distinct differences in carbonization patterns between the two media. The findings of this study are expected to serve as fundamental reference data for the insulation design of LNG-based cryogenic feedthroughs.