Seung Won Lee

Mr. Seung Won Lee

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
SLSeung Won Lee
Seung Won Lee
HKHae-Jong Kim
Hae-Jong Kim
IKIk-Su Kwon
Ik-Su Kwon
JLJang-Seob Lim
Jang-Seob Lim
Demand and need for the application of high voltage direct current (HVDC) are increasing because of high capacity and long-distance transmission. Research on polypropylene (PP) that can increase the operation temperature compared to existing insulation is constantly being considered. This study aimed to evaluate the electrical performance and estimate the life of HVDC application of PP. In this study, a DC V-t characteristic tests were conducted on three types of PP sheets at a temperature of 110 °C. In addition, a life estimation formula based on the electrical stress was derived and the electrical performances were evaluated. The experimental results show that the life exponent of material mixed with block copolymer, homo polymer and high density polyethylene (HDPE) was 23 and the electrical performance was 17% better than block copolymer, thereby demonstrating the reliability and electrical performance for application of HVDC.

31 July 2020 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
SLSeung Won Lee
Seung Won Lee
HKHae-Jong Kim
Hae-Jong Kim
BPByungbae Park
Byungbae Park
HRHee-Suk Ryoo
Hee-Suk Ryoo
JCJeon-Wook Cho
Jeon-Wook Cho
JLJang-Seob Lim
Jang-Seob Lim

24 April 2023 in IEEE Access
Verified
Journal Article
Open access
SLSeung Won Lee
Seung Won Lee
JCJin-Wook Choe
Jin-Wook Choe
IKIk-Su Kwon
Ik-Su Kwon
BPByung-Bae Park
Byung-Bae Park
HKHae-Jong Kim
Hae-Jong Kim
The demand and necessity of direct current (DC) has been increasing owing to large capacity and long distance power transmission. DC application of TP (thermal plastic) materials, which can increase the power transmission capacity compared to existing insulation materials, has been the primary focus of existing studies. This study presents the development of a highly reliable accelerated aging system that can implement the aging conditions of DC power cables. Moreover, we verify its reliability by testing TP model cables and analyzing the aging characteristics. Accordingly, we developed an accelerated aging system that can simulate thermal, electrical, and mechanical stresses collectively. We used the accelerated aging system to perform an accelerated aging test of the TP model cable for 40 cycles. The control precision of the accelerated aging system during the test was numerically calculated. The system was evaluated by using the conduction current and chemical characteristics of the aged TP model cables. The experimental results show that the precision of accelerated aging system is 1 % for 1 cycle. The conduction current of the aged TP model cables was increased by more than 100% before aging, thereby it is verified the performance of the system accelerates the aging of power cables. It is expected that the highly reliable accelerated aging system of power cables can be used to perform long-term reliability tests and as diagnostic technology during the development of DC power cables.

19 December 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KPKeonhee Park
Keonhee Park
SLSeung Won Lee
Seung Won Lee
HKHae-Jong Kim
Hae-Jong Kim
JLJang-Seob Lim
Jang-Seob Lim
Various statistical distributions, such as Weibull, log-normal, and exponential functions, are frequently employed to interpret the dielectric breakdown (BD) strength data of insulating materials, including cross-linked polyethylene, low-density polyethylene, polypropylene (PP), and polyethylene. This study aimed to determine a suitable statistical distribution for analyzing the dielectric BD strength data of PP insulators before and after thermal degradation. Dielectric BD strength tests were conducted on thermally deteriorated PP insulators under various degradation conditions. Additionally, a coefficient of determination was employed to assess the compatibility between the dielectric BD strength data and the statistical distribution of PP insulators before and after thermal degradation. The test results indicate that the coefficient of determination for alternating current BD strength data was 0.955 in the log-normal distribution before degradation and 0.929 in the Weibull distribution after degradation. Consequently, in the analysis of the PP insulation breakdown data, the log-normal distribution was found to be suitable for data before degradation, while the Weibull distribution was deemed suitable for data after degradation. These results can lead to lower errors in the power system design process, enhancing reliability when analyzing the BD strength data of insulation materials.

11 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
SYSung-Ho Yoon
Sung-Ho Yoon
IKIk-Su Kwon
Ik-Su Kwon
JLJinseok LIM
Jinseok LIM
BPByungbae Park
Byungbae Park
SLSeung Won Lee
Seung Won Lee
HKHae-Jong Kim
Hae-Jong Kim
Partial discharge (PD) is a critical indicator of insulation degradation in high-voltage DC systems, necessitating accurate diagnosis to ensure long-term reliability. Conventional AC-based diagnostic methods, such as phase-resolved partial discharge analysis (PRPDA), are ineffective under DC conditions, emphasizing the need for waveform-based analysis. This study presents a novel clustering framework for DC PD pulses, leveraging multi-level wavelet decomposition and statistical feature extraction. Each signal is decomposed into multiple frequency bands, and 70 distinctive waveform features are extracted from each pulse. To mitigate feature redundancy and enhance clustering performance, principal component analysis (PCA) is employed for dimensionality reduction. Experimental data were obtained from multiple defect types and measurement distances using a 22.9 kV cross-linked polyethylene (XLPE) cable system. The proposed method significantly outperformed conventional time-frequency (T-F) mapping techniques, particularly in scenarios involving signal attenuation and mixed noise. Propagation-induced distortion was effectively addressed through multi-resolution analysis. In addition, field noise sources such as HVDC converter switching transients and fluorescent lamp emissions were included to assess robustness. The results confirmed the framework’s capability to distinguish between multiple PD types and noise sources, even in challenging environments. Furthermore, optimal mother wavelet selection and correlation-based feature analysis contributed to improved clustering resolution. This framework supports robust PD classification in practical HVDC diagnostics. The framework can contribute to the development of real-time autonomous monitoring systems for HVDC infrastructure. Future research will explore incorporating temporal deep learning architectures for automated PD-type recognition based on clustered data.

2 September 2024 in IEEE Access
Verified
Journal Article
Open access
SLSeung Won Lee
Seung Won Lee
JCJin-Wook Choe
Jin-Wook Choe
IKIk-Su Kwon
Ik-Su Kwon
JLJin-Seok Lim
Jin-Seok Lim
BPByung-Bae Park
Byung-Bae Park
HKHae-Jong Kim
Hae-Jong Kim
Global warming and environmental issues have necessitated ecofriendly energy generation from offshore wind farms. In this context, submarine cables for offshore wind farms and weak sections of the submarine cables inside the J-tube, which transmit power to offshore substations from the wind turbine generator, have been especially researched. The temperature profiles of the cable inside the J-tube of the offshore wind farm are categorized into three sections: section 1 is the high-temperature region exposed to the air. Section 2 is the temperature-change region, where the cable is repeatedly exposed to the air owing to the rising and falling seawater. Section 3 is the-low temperature region because of the cooling effect of the seafloor. We developed an accelerated aging system for submarine cables and used it to evaluate and analyze the aging characteristics of the submarine cables inside the J-tube. This study presents the different temperature profiles of the three sections of a submarine cable inside a J-tube by applying thermal, electrical, and water stress to the test sample using the developed aging system. The experimental results show that the precision of the accelerated aging system was ±1% for 1 cycle. After aging over 60 cycles, the dielectric strength of the insulation in section 2, where the temperature changes were extreme owing to the rising and falling water level, was decreased by 9% when compared with that before aging. Therefore, section 2 is considered the weak section of the J-tube and requires priority monitoring and diagnosis during cable operation.