Geothermal heating is considered to be one of the low-carbon-energy technologies for building heating. Aiming at the problem that the operating cost and investment cost of geothermal heating systems are still high, the conventional geothermal heating system coupled with energy storage for office building heating is studied in this paper. Four operational strategy models of the coupled system are established based on time-of-use electricity prices. A genetic algorithm is used to find the optimal value of each decision variable using minimization of levelized cost of heat (LCOH) as the objective function. The influences of electricity and equipment prices on the optimal values of the decision variables are discussed. Four operation strategies are investigated. If only operating cost is considered in the optimization, comparison shows that the best operation strategy is the one giving high priority to use the energy storage tank for heating during the peak electricity period. However, if the investment cost is further considered in the optimization, the best operation strategy is the one using the energy storage tank for heat load peak-regulating. In addition, based on the minimization of LCOH, an optimal energy storage ratio is found for each scenario, and suitable conditions of using energy storage tank are discussed. The geothermal heating system coupled with energy storage can have a good performance when the peak-valley electricity price difference is higher than CNY 0.566/kW·h (USD 0.0847/kW·h)+ or the energy storage tank price is lower than CNY 900/m3 (USD 134.64/m3). The results obtained from this study prove that the cost of geothermal heating systems can be effectively reduced by choosing an optimal operation strategy and using an energy storage device with an optimal energy storage ratio.
Medium-depth and deep geothermal energy has been widely used because of its abundant resources and supply stability. Recently, attention has been given to the closed-loop heat extraction system using a deep borehole heat exchanger (DBHE), which enables geothermal energy to be harnessed almost everywhere. In this study, a check valve is adopted in a DBHE system in which the whole section of the well is used for heat extraction in winter during building heating and the upper part of the well is used for heat injection in summer during building cooling. The influence of injected water flowrates, water inlet temperatures, depths of the check valve and formation of thermal conductivities on the performance of this novel DBHE system has been investigated. It is found that heat injection through the upper part of the well in summer can improve the heat extraction rates to a certain extent during the heating season. In summer, the inlet temperature of water has a great influence on the heat injection rates. The increase in the depth of the check valve improves the heat injection rates of the novel DBHE system. When the depth of the check valve is 900 m, the heat injection rates in summer can reach 51.03 kW, which is 27.55% of the heat extraction rates in winter. In this case, the heat injection in summer has the greatest effect on the improvement of heat extraction in winter, which is 6.05 kW, accounting for 3.38% of the heat extraction in that year. It is found that the thermal conductivity of the formation has a great influence on the heat extraction rates in winter and heat injection rates in summer. The proposed novel DBHE system can be used to inject the heat discharged from the building in summer and extract geothermal energy for building heating in winter, forming a better heat balance at certain depths and resulting in a sustainable operation for heating and cooling. Another benefit of using this system is that the heat discharged from air conditioning into the air can be reduced in summer and “urban thermal pollution” can be alleviated.
Hybrid geothermal–solar systems leverage complementary resources to enhance efficiency, dispatchability, and low-carbon supply. This review compares mainstream configurations (solar-preheating configurations, solar-superheating configuration, and other emerging concepts) and reports typical performance gains—thermal efficiency of 5–80% and exergy efficiency up to ~60%—observed across resource contexts. Findings indicate that preheating routes are generally preferable under medium direct normal irradiance (DNI) and operation-and-maintenance (O&M)-constrained conditions, while superheating routes become attractive at high DNI with thermal storage; integrated multigeneration systems can deliver system-level benefits for multi-energy parks and district applications. In addition, this paper identifies technical bottlenecks—source matching, storage dependence, and the absence of a unified evaluation—and summarizes control/optimization strategies, including emerging advanced artificial-intelligence algorithms. In addition, the review highlights a standardized comprehensive performance evaluation framework, which covers thermal and exergy efficiency, net power output, complexity, the levelized cost of electricity (LCOE), reliability, and storage. Finally, according to the research status and findings, future research directions are proposed, which pave the way for more effective exploitation of geothermal and solar energy.
With the changing world energy structure, the development of renewable energy sources is gradually accelerating. Among them, close attention has been given to geothermal energy because of its abundant resources and supply stability. In this article, a deep borehole heat exchanger (DBHE) is coupled with a heat pump system to calculate the heat supply and daily electricity consumption of the system. To make better use of the peaks and valleys in electricity prices, the following three daily operating modes were studied: 24-h operation (Mode 1), 8-h operation plus 16-h non-operation (Mode 2), and two cycles of 4-h operation and 8-h non-operation (Mode 3). Simulation results show that scheduled non-continuous operation can effectively improve the outlet temperature of the heat extraction fluid circulating in the DBHE. The heat extraction rates of Mode 1 is 190.9 kW for mass flowrate of 9 kg/s; in Mode 2 and Mode 3 cases, the rates change to 304.7 kW and 293.0 kW, respectively. The daily operational electricity cost of Mode 1 is the greatest because of 24-h operation; due to scheduled non-continuous operation, the daily operational electricity cost of Mode 3 is only about 66% of that of Mode 2. After an 8-month period without heating, the formation-temperature can be restored within 4 °C of its original state; 90% recovery of the formation-temperature can be achieved by the end of the second month of the non-operation season.
The thermodynamic analysis of an increasing-pressure endothermic power cycle (IPEPC) integrated with closed-loop geothermal energy extraction (CLGEE) in a geothermal well at a depth from 2 km to 5 km has been carried out in this study. Using CLGEE can avoid some typical problems associated with traditional EGS technology, such as water contamination and seismic-induced risk. Simultaneous optimization has been conducted for the structural parameters of the downhole heat exchanger (DHE), the CO2 mixture working fluid type, and the IPEPC operating parameters. The CO2-R32 mixture has been selected as the optimal working fluid for the IPEPC based on the highest net power output obtained. It has been found that, when the DHE length is 4 km, the thermosiphon effect is capable of compensating for 53.8% of the pump power consumption. As long as the DHE inlet pressure is higher than the critical pressure, a lower DHE inlet pressure results in more power production. The power generation performance of the IPEPC has been compared with that of the organic Rankine cycle (ORC), trans-critical carbon dioxide cycle (t-CO2), and single-flash (SF) systems. The comparison shows that the IPEPC has more net power output than other systems in the case that the DHE length is less than 3 km, along with a DHE outer diameter of 0.155 m. When the DHE outer diameter is increased to 0.22 m, the IPEPC has the highest net power output for the DHE length ranging from 2 km to 5 km. The application scopes obtained in this study for different power generation systems are of engineering-guiding significance for geothermal industries.
In this study, a power cycle (IPEC), with an increasing pressure endothermic process in a downhole heat exchanger (DHE) and a CO2-based working fluid mixture, was developed for geothermal power generation. The increasing pressure endothermic process, which cannot be achieved in a conventional evaporator on the ground, was realized using the gravitational potential energy in the DHE. The parameters of the power cycle and the structural size of the DHE were optimized simultaneously. Using CO2-R32 as the working fluid of the IPEC provides the highest net power output. The net power generated with the IPEC was compared with a single-flash (SF) system, a trans-critical CO2 (t-CO2) system, and an organic Rankine cycle (ORC) under the same heat source and sink conditions. Six selection maps were generated for choosing the optimum power cycle for electricity production, in which four power generation systems (ORC, t-CO2, IPEC, and SF) were included, and two DHE diameters (0.155 m and 0.22 m) were investigated. It was found that the IPEC system had more net power output than the other three systems (ORC, t-CO2, and SF) under the conditions that the geofluid’s mass flow rate was less than 10 kg/s and its temperature was lower than 180 °C.