Eline Oppersma

Dr. Eline Oppersma

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2015 in Journal of Clinical Sleep Medicine
Verified
Journal Article
Closed access
MEMichiel M Eijsvogel
Michiel M Eijsvogel
RURinse Ubbink
Rinse Ubbink
JDJanita Dekker
Janita Dekker
EOEline Oppersma
Eline Oppersma
FJFrans H de Jongh
Frans H de Jongh
MBMarjolein G Brusse-Keizer
Marjolein G Brusse-Keizer
Positional therapy (PT) is an effective therapy in positional obstructive sleep apnea syndrome (POSAS) when used, but the compliance of PT is low. The objective of this study was to investigate whether a new kind of PT is effective and can improve compliance. 29 patients were treated with the Sleep Position Trainer (SPT), 26 patients with the Tennis Ball Technique (TBT). At baseline and 1 month polysomnography, Epworth Sleepiness Scale (ESS) and the Quebec Sleep Questionnaire (QSQ) were taken. Daily compliance was objectively measured in both groups. Both therapies prevent supine sleep position to a median of 0% (min-max: SPT 0.0% to 67%, TBT 0.0% to 38.9%), resulting in a treatment success (AHI <5) in 68.0% of the SPT and 42.9% of the TBT patients. The ESS at baseline was <10 in both groups. Sleep quality parameters as wake after sleep onset (WASO; p = 0.001) and awakenings (p = 0.006) improved more in the SPT group. Total QSQ scores (0.4±0.2, p = 0.03) and the QSQ domains nocturnal symptoms (0.7±0.2, p = 0.01) and social interactions (0.8±0.3, p = 0.02) changed in favor of the SPT group. Effective compliance (≥4 h/night + ≥5 days/week) was 75.9% for the SPT and 42.3% for the TBT users (p = 0.01). In mild POSAS with normal EES the new SPT device and the standard TBT are equally effective in reducing respiratory indices. However, compared to the TBT, sleep quality, quality of life, and compliance improved significantly more in the SPT group.

1 November 2017 in Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
EOEline Oppersma
Eline Oppersma
NHNima Hatam
Nima Hatam
JDJonne Doorduin
Jonne Doorduin
JHJohannes G. van der Hoeven
Johannes G. van der Hoeven
GMGernot Marx
Gernot Marx
CBChristian S. Bruells
Christian S. Bruells
Assessment of diaphragmatic effort is challenging, especially in critically ill patients in the phase of weaning. Fractional thickening during inspiration assessed by ultrasound has been used to estimate diaphragm effort. It is unknown whether more sophisticated ultrasound techniques such as speckle tracking are superior in the quantification of inspiratory effort. This study evaluates the validity of speckle tracking ultrasound to quantify diaphragm contractility. Thirteen healthy volunteers underwent a randomized stepwise threshold loading protocol of 0–50% of the maximal inspiratory pressure. Electric activity of the diaphragm and transdiaphragmatic pressures were recorded. Speckle tracking ultrasound was used to assess strain and strain rate as measures of diaphragm tissue deformation and deformation velocity, respectively. Fractional thickening was assessed by measurement of diaphragm thickness at end-inspiration and end-expiration. Strain and strain rate increased with progressive loading of the diaphragm. Both strain and strain rate were highly correlated to transdiaphragmatic pressure (strain r2 = 0.72; strain rate r2 = 0.80) and diaphragm electric activity (strain r2 = 0.60; strain rate r2 = 0.66). We conclude that speckle tracking ultrasound is superior to conventional ultrasound techniques to estimate diaphragm contractility under inspiratory threshold loading. NEW & NOTEWORTHY Transdiaphragmatic pressure using esophageal and gastric balloons is the gold standard to assess diaphragm effort. However, this technique is invasive and requires expertise, and the interpretation may be complex. We report that speckle tracking ultrasound can be used to detect stepwise increases in diaphragmatic effort. Strain and strain rate were highly correlated with transdiaphragmatic pressure, and therefore, diaphragm electric activity and speckle tracking might serve as reliable tools to quantify diaphragm effort in the future.

2 January 2024 in Critical Care
Verified
Journal Article
Open access
PDF file
AJA. H. Jonkman
A. H. Jonkman
RWR. S. P. Warnaar
R. S. P. Warnaar
WBW. Baccinelli
W. Baccinelli
NCN. M. Carbon
N. M. Carbon
RDR. F. D’cruz
R. F. D’cruz
EOEline Oppersma
Eline Oppersma
Surface electromyography (sEMG) can be used to measure the electrical activity of the respiratory muscles. The possible applications of sEMG span from patients suffering from acute respiratory failure to patients receiving chronic home mechanical ventilation, to evaluate muscle function, titrate ventilatory support and guide treatment. However, sEMG is mainly used as a monitoring tool for research and its use in clinical practice is still limited—in part due to a lack of standardization and transparent reporting. During this round table meeting, recommendations on data acquisition, processing, interpretation, and potential clinical applications of respiratory sEMG were discussed. This paper informs the clinical researcher interested in respiratory muscle monitoring about the current state of the art on sEMG, knowledge gaps and potential future applications for patients with respiratory failure.

25 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JZJoske van der Zande
Joske van der Zande
MSMarc Strik
Marc Strik
RDRemi Dubois
Remi Dubois
SPSylvain Ploux
Sylvain Ploux
SASaer Abu-Alrub
Saer Abu-Alrub
PBPierre Bordachar
Pierre Bordachar
Smartwatches that support the recording of a single-lead electrocardiogram (ECG) are increasingly being used beyond the wrist, by placement on the ankle and on the chest. However, the reliability of frontal and precordial ECGs other than lead I is unknown. This clinical validation study assessed the reliability of an Apple Watch (AW) to obtain conventional frontal and precordial leads as compared to standard 12-lead ECGs in both subjects without known cardiac anomalies and patients with underlying heart disease. In 200 subjects (67% with ECG anomalies), a standard 12-lead ECG was performed, followed by AW recordings of the standard Einthoven leads (leads I, II, and III) and precordial leads V1, V3, and V6. Seven parameters (P, QRS, ST, and T-wave amplitudes, PR, QRS, and QT intervals) were compared through a Bland–Altman analysis, including the bias, absolute offset, and 95% limits of agreement. AW-ECGs recorded on the wrist but also beyond the wrist had similar durations and amplitudes compared to standard 12-lead ECGs. Significantly greater amplitudes were measured by the AW for R-waves in precordial leads V1, V3, and V6 (+0.094 mV, +0.149 mV, +0.129 mV, respectively, all p < 0.001), indicating a positive bias for the AW. AW can be used to record frontal, and precordial ECG leads, paving the way for broader clinical applications.

15 October 2020 in SLEEP
Verified
Journal Article
Open access
PDF file
EOEline Oppersma
Eline Oppersma
WGWolfgang Ganglberger
Wolfgang Ganglberger
HSHaoqi Sun
Haoqi Sun
RTRobert J Thomas
Robert J Thomas
MWM Brandon Westover
M Brandon Westover
Study Objectives: Sleep-disordered breathing is a significant risk factor for cardiometabolic and neurodegenerative diseases. High loop gain (HLG) is a driving mechanism of central sleep apnea or periodic breathing. This study presents a computational approach that identifies “expressed/manifest” HLG via a cyclical self-similarity feature in effort-based respiration signals. Methods: Working under the assumption that HLG increases the risk of residual central respiratory events during continuous positive airway pressure (CPAP), the full night similarity, computed during diagnostic non-CPAP polysomnography (PSG), was used to predict residual central events during CPAP (REC), which we defined as central apnea index (CAI) higher than 10. Central apnea labels are obtained both from manual scoring by sleep technologists and from an automated algorithm developed for this study. The Massachusetts General Hospital sleep database was used, including 2466 PSG pairs of diagnostic and CPAP titration PSG recordings. Results: Diagnostic CAI based on technologist labels predicted REC with an area under the curve (AUC) of 0.82 ± 0.03. Based on automatically generated labels, the combination of full night similarity and automatically generated CAI resulted in an AUC of 0.85 ± 0.02. A subanalysis was performed on a population with technologist-labeled diagnostic CAI higher than 5. Full night similarity predicted REC with an AUC of 0.57 ± 0.07 for manual and 0.65 ± 0.06 for automated labels. Conclusions: The proposed self-similarity feature, as a surrogate estimate of expressed respiratory HLG and computed from easily accessible effort signals, can detect periodic breathing regardless of admixed obstructive features such as flow limitation and can aid the prediction of REC.

1 January 2013 in Critical Care
Verified
Journal Article
Open access
PDF file
EOEline Oppersma
Eline Oppersma
JDJonne Doorduin
Jonne Doorduin
EHErik H.F.M. van der Heijden
Erik H.F.M. van der Heijden
JHJohannes G van der Hoeven
Johannes G van der Hoeven
LHLeo Ma Heunks
Leo Ma Heunks
In an effort to reduce the complications related to invasive ventilation, the use of noninvasive ventilation (NIV) has increased over the last years in patients with acute respiratory failure. However, failure rates for NIV remain high in specific patient categories. Several studies have identified factors that contribute to NIV failure, including low experience of the medical team and patient–ventilator asynchrony. An important difference between invasive ventilation and NIV is the role of the upper airway. During invasive ventilation the endotracheal tube bypasses the upper airway, but during NIV upper airway patency may play a role in the successful application of NIV. In response to positive pressure, upper airway patency may decrease and therefore impair minute ventilation. This paper aims to discuss the effect of positive pressure ventilation on upper airway patency and its possible clinical implications, and to stimulate research in this field.