With the increase in doubly fed induction generator-based wind energy conversion systems (DFIG-WECS) worldwide, improving the fault ride-through (FRT) capability of the entire system has been given much attention. Enhancement of the FRT capability of a DFIG-WECS is conventionally realized by employing a flexible AC transmission system device with a proper control system. This paper presents a non-conventional method for the improvement of the FRT of DFIG-WECS, using a high-temperature superconducting coil interfaced with the DC-link of the rotor and stator side converters through a DC-chopper. A fractional-order proportional-integral (FOPI) controller is utilized to regulate the DC-chopper duty cycle in order to properly manage the power flow between the DC-link and the coil. Two optimization techniques, Harmony Search and Grey Wolf Optimizer, are employed to determine the optimum size of the superconducting coil along with the optimum parameters of the FOPI controller. The effectiveness of the two proposed optimization techniques is highlighted through comparing their performance with the well-known particle swarm optimization technique.
Most power system planners are interested in the savings of electrical power consumption. Various references demonstrate that the highest consumed power is by the lighting systems standing around 19% of worldwide energy consumption. This article presents novel design methodology leading to maximizing revenue due to savings in electrical energy consumption through energy efficient installations. This hybrid methodology is built by combining benefits of the two traditional lighting design methods (lumen and specific connected load methods). This results in developing a new mathematical and applicable model with many advantages such as: high accuracy, fast calculations and most economical design. This proposed methodology is supported by MATLAB® package to shorten the long time consumed by conventional procedures and simplify the complex manual calculations. The hybrid method verifies its effectiveness and efficiency for achieving the maximum savings in energies and costs through the detailed discussion of case studies. A comparison with traditional designs will be introduced to ensure the achieved savings in costs leading to high quality and efficiency of power systems. By practically applying this new hybrid technique particularly for the Egyptian residential and commercial sectors, the system is expected to achieve a huge savings in consumed lighting energies and costs, which can reach 4489.433415 million E£ "≈ 280.5895 million $ "USD"" each year. The presented case studies give accurate and promising results for the proposed methodology as a new trend in energy and money saving system, which is verified by implementing two case studies and comparing with results from DIALux program. The results of the proposed methodology are very effective compared with that of conventional methods for marked benchmarking features and validation. MATLAB® simulation results of the proposed technique are implemented to verify its feasibility for any activity. Header of solarlits.com
Energy is a vital component of life today, and providing reliable power access remains a significant global challenge, particularly in remote areas. In Egypt, several isolated regions, including parts of South Sinai, suffer from limited electricity access. This study presents an enhanced environmental and techno-economic modeling of an off-grid hybrid renewable energy microgrid (HREM) tailored for such regions. A proposed configuration combining photovoltaic (PV) panels, wind turbines (WTs), a converter (CONV), and battery energy storage is evaluated to meet the residential energy demand of an isolated community in South Sinai. Four feasible system models, PV/CONV/BAT, WT/CONV/BAT, PV/WT/CONV/BAT, and a standalone diesel generator, were simulated using hybrid optimization of multiple energy resources. The cost of energy was analyzed under different scenarios. The results show that the combination of a 1109 kW PV system, 16 × 25 kW WTs, 439 kW converter, and 353 batteries is the best configuration that leads to the lowest values of Net Present Cost (NPC) and Levelized Cost of Energy (COE), and zero unmet load, making it the most economically and environmentally viable configuration.
In this paper Static Synchronous Compensator (STATCOM) is used for improving the performance of the power grid with wind turbine that drives synchronous generator. The main feature of the STATCOM is that it has the ability to absorb or inject rapidly reactive power to grid. Therefore the voltage regulation of the power grid with STATCOM device is achieved. STATCOM also improves the stability of the power system after occurring severe disturbance such as faults, or suddenly step change in wind speed. The proposed STATCOM controller is a Proportional-Integral (PI) controller tuned by Genetic Algorithm (GA). An experimental model was built in Helwan University to the proposed system. The system is tested at different operating conditions. The experimental results prove the effectiveness of the proposed STATCOM controller in damping the power system oscillations and restoring the power system voltage and stability.