Fathalla Fereig Selim

Prof. Fathalla Fereig Selim

Vice Dean For Community and Environmental Affairs, Faculty of Engineering, Kafrelshiekh University, Egypt
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
AOAbdul Ghani Olabi
Abdul Ghani Olabi
Hegazy RezkHegazy Rezk
Hegazy Rezk
Mohammad AbdelkareemMohammad Abdelkareem
Mohammad Abdelkareem
TWTabbi Wilberforce
Tabbi Wilberforce
Hussein Mohamed MaghrabieHussein Mohamed Maghrabie
Hussein Mohamed Maghrabie
AZAlaa A. Zaky
Alaa A. Zaky
In this paper, a modified bald eagle search optimization algorithm was applied for the first time to determine the parameters of the triple diode model (TDM) of perovskite solar cells (PSCs). Two experimental datasets are considered; the first is measured I–V points for a PSC at standard conditions. The second consists of the measured I–V points for a modified PSC. In contrast, the cost function to be minimized is the root mean square error (RMSE) between the experimental dataset and the calculated one. To prove the superiority of modified bald eagle search optimization (mBES), a comparison with the original bald eagle search optimization (BES), particle swarm optimizer (PSO), Hunger games search (HGS), and recent Coronavirus Disease Optimization Algorithm (COVIDOA) was implemented. Furthermore, statistical analysis of ANOVA and Tukey tests was performed. The results demonstrate the lead of the recommended mBES in identifying the parameters of the TDM for PSCs, where the RMSE achieved the least value among the used optimization algorithms in this study.

5 July 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
AZAlaa A. Zaky
Alaa A. Zaky
RGRania Ghoniem
Rania Ghoniem
FSFathalla Fereig Selim
Fathalla Fereig Selim
The proton exchange membrane fuel cell (PEMFC) is a green energy converter that is based on the chemical reaction process. The behavior of this system can change with time due to aging and operating conditions. Knowing the current state of this system requires an accurate model, and an exact PEMFC model requires precise parameters. These parameters should be identified and used to properly fit the polarization curve in order to effectively replicate the PEMFC behavior. This work suggests a precise unknown PEMFC parameter extraction based on a new metaheuristic optimization algorithm called the modified bald eagle search algorithm (mBES). The mBES is an optimization algorithm based on the principles of bald eagle behavior that combines local search and global search to achieve a balance between the exploration and exploitation of search spaces. It is a powerful and efficient technique for optimization problems where accurate and near-optimal solutions are desired. To approve the accuracy of the proposed identification approach, the proposed algorithm is compared to the following metaheuristic algorithms: bald eagle search algorithm (BES), artificial ecosystem-based optimization (AEO), leader Harris Hawk’s optimization (LHHO), rain optimization algorithm (ROA), sine cosine algorithm (SCA), and salp swarm algorithm (SSA). This evaluation process is applied to two commercialized PEMFC stacks: BCS 500 W PEMFC and Avista SR-12 PEM. The extracted parameters’ accuracy is measured as the sum of square errors (SSE) between the results produced by the optimizer and the experimental data in the objective function. As a result, the proposed PEMFC optimizing model outperforms the comparison models in terms of system correctness and convergence. The proposed extraction strategy, mBES, obtained the best results, with a fitness value of 0.011364 for the 500 W BCS and 0.035099 for the Avista SR-12 500 W PEMFC.

22 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
Mohamed I. AbdelwanisMohamed I. Abdelwanis
Mohamed I. Abdelwanis
Essam Eddin M. RashadEssam Eddin M. Rashad
Essam Eddin M. Rashad
Ibrahim B. M. TahaIbrahim B. M. Taha
Ibrahim B. M. Taha
FSFathalla Fereig Selim
Fathalla Fereig Selim
This paper is interested in implementing and controlling a modified six-phase induction motor (MSPIM) when fed from a three-phase supply either via an inverter or with a direct grid connection loaded by a centrifugal pump. The main aims of using the MSPIM are to enhance motor reliability and reduce torque pulsation. A three-to-six phase transformer has been designed, implemented, and employed to enable the SPIM to be driven from a three-phase supply. It is preferable to use the three-to-six phase transformers integrated with three-phase inverter on using the six-phase inverter to generate lower values of harmonics and lower steady-state error of speed and reduce the starting current and because also it isolates the primary circuit from the secondary, and the cost will be lower compared to the design of a special six-phase inverter. Dynamic models of SPIM, three-to-six phase transformer, and three-phase variable speed drive are derived. Then, a scalar (V/F) closed-loop control of SPIM is employed, and the results are discussed. Fine-tuning of PID controllers is used to keep the motor speed tracking the reference value. A low pass filter is connected to reduce the ripple of voltage and current waveforms. An experimental setup has been built and implemented to check the possibility of controlling SPIM by a variable speed drive system fed from a three-to-six phase transformer. It is found that the proposed method can be effectively used to drive the SPIM from a three-phase supply.

22 May 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
FSFathalla Fereig Selim
Fathalla Fereig Selim
MHMohamed A. Hassan
Mohamed A. Hassan
AAAhmed Azmy
Ahmed Azmy
EAEman G. Atiya
Eman G. Atiya
Dissolved gas analysis (DGA) is a technique, which is more frequently employed in power transformers to assess the incipient faults that are developed in oil-immersed transformers. Duval triangle-I is the simplest methodology for DGA to evaluate the incipient faults. In addition, it is more accurate than other conventional methods like Doernenburg (DRM), Roger’s, and IEC techniques. The main disadvantage of conventional methods is their inability to identify a large percentage of fault cases. However, Hydrogen (H $_{{2}}\text {)}$ concentration, which is crucial for diagnosing various faults, particularly low temperature thermal fault and partial discharge (PD), was not considered in the Duval triangle-I method. Rather, only three gases, which are Methane (CH $_{{4}}\text {)}$ , Ethylene (C2H $_{{4}}\text {)}$ , and Acetylene (C2H $_{{2}}\text {)}$ , are used in Duval triangle-I method. Consequently, this article introduces a new graphical method for power transformer incipient faults discrimination based on three new ratios of gases that consider the concentration of H2 and the influence of ethane (C2H $_{{6}}\text {)}$ . These three ratios are converted to a point ( ${x},{y}\text {)}$ in the cartesian plane. Based on the position of this point within the new graphical shape, the type of incipient fault is determined with an accuracy reaching 92%. A practical DGA database is collected from different transformers in service and IEC TC 10 database and used to evaluate the accuracy of this method. Additionally, various incipient faults are experimentally simulated in the laboratory and their results are utilized in the proposed method. This methodology aims to overcome the drawbacks of Duval triangle-I and other conventional methods. The results ensured that the proposed graph provides better diagnosis accuracy when compared to Duval triangle-I and other techniques.

3 June 2024 in IEEE Access
Verified
Journal Article
Open access
MNMasood Nazir
Masood Nazir
FSFathalla Fereig Selim
Fathalla Fereig Selim
AAAijaz Ahmad
Aijaz Ahmad
Ikhlaq HussainIkhlaq Hussain
Ikhlaq Hussain
SDSamir Dawoud
Samir Dawoud
AZAlaa A. Zaky
Alaa A. Zaky
This work proposes the techno-economic analysis of a three-phase, three wire grid integrated third-generation perovskite solar cells-wind energy conversion system (PSC-WECS) controlled by a two-level voltage source converter (VSC) which is driven by the application of polynomial zero-attracting least mean square (PZA-LMS) algorithm. The proposed algorithm enhances the dynamic performance of the system by introducing sinusoidal grid currents with low total harmonic distortion (THD) which enhances system performance by providing acceptable outcomes under dynamic loading, fluctuating wind velocity, and solar insolation by compensating for load reactive power and balancing load and power demands at the point of coupling. This work replaces the conventional silicon PVs with PSCs to improve the economics of power generation thanks to their higher efficiency. For relative comparisons, the performance of the proposed 36kWPSC-WECS is compared with the conventional silicon PV-WECS. The results reveal that the proposed system has a low net present cost (NPC) of $68843 compared to the conventional system which costs $160917, translating to a reduction of 58% in total cost. Sensitivity Analysis (SA) is performed to analyse the dependence of optimal solutions on the uncertainty of key variables namely NPC, cost of energy (COE), windspeed & insolation. The results show that the total NPC is more sensitive to the COE and the average wind speed as compared to the other variables. Moreover, the area covered by the proposed system is reduced by 50% while as the cost of power generation is reduced by 72% due to the high efficiency of PSCs. The results obtained in MATLAB/Simulink and HOMER to determine the optimum quantity of the renewable energy sources (RES) model demonstrate the effectiveness of the recommended system.

26 November 2021 in Electronics
Verified
Journal Article
Open access
PDF file
FSFathalla Fereig Selim
Fathalla Fereig Selim
AAAlmoataz Abdelaziz
Almoataz Abdelaziz
Ibrahim B. M. TahaIbrahim B. M. Taha
Ibrahim B. M. Taha
Clean and renewable energy sources are the preferable power system generations for the overall world. This research aims to present a very highly integrated, economic, professional, and simple construction, clean and natural resources usage of the renewable hybrid generation system. This research performs analysis, systematic representation, evaluation, and design of the hybrid proposed system—pico-hydraulic from home usage water and photovoltaic (PV)—to generate an optimal renewable generation system using a new professional control system. Applying this proposed technique in Egypt shows that the hybrid system successfully overcame Egypt’s energy crisis. Renewable energy will rise to 8.782% by increasing 7.323% (14,408.83 GWh/Y). Besides, this system increases the power supply reliability; it gives an additional emergency supply and reduces the exhausts from other generation stations (e.g., CO2). The saving from this hybrid system is very effective for; the residential sector (subscribes), which will be ranged from 9599.298 million E£/10Ys up to 86,393.68 million E£/10Ys that equals 5399.6 million $, government to use this extra generation energy to reduce the maximum loads from various stations. A practical model has been presented with results to verify the high efficiency of the proposed system that illustrates the effective performance of the used hybrid system.