Xuefeng Ge

Dr. Xuefeng Ge

Distribution Network Technology Research Institute, State Grid Jiangsu Electric Power Co., Ltd. Electric Power Science Research Institute, Nanjing, Jiangsu, China
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
Xuefeng GeXuefeng Ge
Xuefeng Ge
MCMengxing Chen
Mengxing Chen
MSMingming Shi
Mingming Shi
QZQi Zhou
Qi Zhou
JLJuan Li
Juan Li
YYYubo Yuan
Yubo Yuan
This paper proposes a novel single‐stage buck‐boost three‐Level neutral‐point‐clamped (NPC) inverter with two independent dc sources coupled for the grid‐tied photovoltaic (PV) application, which can effectively solve the unbalanced operational conditions generally appearing between two independent PV sources. The proposed control scheme can simultaneously guarantee the maximum power point (MPP) operation of both PV sources and maintain the output waveform quality. Compared to the traditional two‐stage PV inverter, the proposed NPC inverter could reduce the PV array voltage requirement and the voltage rating of dc‐link capacitors; also it shows advantages in operational efficiency. MATLAB simulations and experimental results are presented to examine the performance of the proposed three‐level NPC inverter.

26 November 2025 in Electronics
Verified
Journal Article
Open access
PDF file
JDJunpeng Deng
Junpeng Deng
Liangzhong YaoLiangzhong Yao
Liangzhong Yao
JDJinglei Deng
Jinglei Deng
SLShuai Liang
Shuai Liang
RYRongxiang Yuan
Rongxiang Yuan
Xuefeng GeXuefeng Ge
Xuefeng Ge
Existing studies on commutation failure during fault recovery (CFFR) in line-commutated converter high-voltage direct current (LCC-HVDC) systems often neglect the critical influence of phase-locked loop phase tracking error (PLL-PTE) and fail to provide effective control strategies to address this issue. This paper investigates the influence of PLL-PTE on CFFR through electromagnetic transient simulations based on a modified CIGRE benchmark model. The study reveals that phase angle jump (PAJ) caused by DC power fluctuations (DPF) and AC network reconfigurations (ANR) is the fundamental source of PLL-PTE, which in turn leads to the occurrence of CFFR. To mitigate this, a novel control strategy is proposed that dynamically adjusts the extinction angle based on historical and predicted PAJ data. Simulation results demonstrate that the proposed method effectively suppresses CFFR under various fault conditions, including different fault types, locations, resistances, and initiation times. Compared with existing control schemes, the proposed approach avoids adverse side effects while exhibiting strong robustness and adaptability. The proposed control strategy significantly enhances the stability and reliability of LCC-HVDC systems, offering great potential for practical application in increasingly complex power grid environments.


12 October 2026 in Energies
Verified
Journal Article
Open access
PDF file
Xuefeng GeXuefeng Ge
Xuefeng Ge
QZQi Zhou
Qi Zhou
XFXin Fang
Xin Fang
SCShi Chen
Shi Chen
To address the delayed dynamic response and susceptibility to overcurrent surges of the triple-active-bridge (TAB)-based modular multilevel DC-link T-type converter power electronic transformer (MMDTC-PET) under load step transients, this paper proposes a composite model predictive control (MPC) strategy to enhance the system’s disturbance rejection capability. The proposed strategy adopts a hierarchical control architecture comprising a proportional-integral (PI) outer power loop and an MPC inner loop. To tackle the heavy computational burden caused by multi-port coupling, dimensionality reduction is performed by equating the phase-shift ratios of the two primary-side ports of the TAB, which effectively mitigates the computational cost. Furthermore, a dynamic overcurrent hard-constraint penalty term and a control-effort smoothing term are incorporated into the multi-objective cost function. This not only achieves steady-state error-free tracking of the output voltage but also enhances physical operational safety under complex conditions at the algorithmic level. Comparative simulation results under various operating conditions demonstrate that, compared with the traditional PI-based phase-shift control, the proposed strategy exhibits a faster dynamic response under load step conditions. Moreover, it suppresses transient power overshoots and overcurrent impacts during input voltage sags and recoveries, thereby significantly improving the transient disturbance rejection capability and operational robustness of the system.

5 November 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PZPeng Zhang
Peng Zhang
WPWei Pei
Wei Pei
GZGuoju Zhang
Guoju Zhang
EZEnze Zhu
Enze Zhu
Xuefeng GeXuefeng Ge
Xuefeng Ge
CZChenyu Zhang
Chenyu Zhang
The growing demand for high-power-density and high-efficiency power converters has stimulated a strong interest in soft-switching techniques. However, conventional zero-voltage switching (ZVS) methods based on variable switching frequency control suffer from an excessively wide switching frequency range and large current ripple. To solve this problem, this paper proposes a carrier-based phase-shift modulation scheme with a low calculation burden for parallel silicon carbide (SiC) converters to achieve full range zero-voltage switching (ZVS). A dynamically adjustable phase-shift angle is applied to a pair of new carriers in each carrier cycle, generating a sufficiently large circulating current flowing through the parallel half-bridge (HB) legs to enable all SiC MOSFETs to achieve ZVS operation. As the HB currents are reshaped into a quadrilateral waveform, this operation mode is referred as quadrilateral current mode (QCM). First, a pair of new carriers satisfying the operational requirements of QCM is constructed. Subsequently, the corresponding phase-shift angle is precisely calculated and dynamically updated to create ZVS conditions. Finally, experimental results are provided to validate the advantages of the proposed method in switching loss reduction and efficiency improvement.