Maxime Pastor

Dr. Maxime Pastor

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2023 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
Joel GREFFIERJoel GREFFIER
Joel GREFFIER
MPMaxime Pastor
Maxime Pastor
SSSalim Aymeric Si-Mohamed
Salim Aymeric Si-Mohamed
CGCynthia Goutain-Majorel
Cynthia Goutain-Majorel
APAude Peudon-Balas
Aude Peudon-Balas
DDDjamel Dabli
Djamel Dabli

1 March 2024 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
Joel GREFFIERJoel GREFFIER
Joel GREFFIER
SFSebastian Faby
Sebastian Faby
MPMaxime Pastor
Maxime Pastor
JFJulien Frandon
Julien Frandon
JEJulien Erath
Julien Erath
DDDjamel Dabli
Djamel Dabli

16 May 2024 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
Joel GREFFIERJoel GREFFIER
Joel GREFFIER
DDDjamel Dabli
Djamel Dabli
SFSebastian Faby
Sebastian Faby
MPMaxime Pastor
Maxime Pastor
CCCédric Croisille
Cédric Croisille
JBJean Paul Beregi
Jean Paul Beregi

19 September 2024 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
MPMaxime Pastor
Maxime Pastor
Djamel DabliDjamel Dabli
Djamel Dabli
RLRaphaël Lonjon
Raphaël Lonjon
CSChris Serrand
Chris Serrand
FSFehmi Snene
Fehmi Snene
Joel GREFFIERJoel GREFFIER
Joel GREFFIER

1 January 2026 in Radiology
Verified
Journal Article
Closed access
POPatrick Omoumi
Patrick Omoumi
CMCharbel Mourad
Charbel Mourad
SRStanislas Rapacchi
Stanislas Rapacchi
MPMaxime Pastor
Maxime Pastor
Applying the Dixon method to fast spin-echo MRI sequences can generate four sets of contrasts, providing both morphologic and quantitative information, thereby expanding the range of applications in musculoskeletal imaging.

29 November 2025 in Diagnostic and Interventional Imaging
Verified
Journal Article
Open access
Joel GREFFIERJoel GREFFIER
Joel GREFFIER
CSCécile Salvat
Cécile Salvat
MPMaxime Pastor
Maxime Pastor
VBValérie Bousson
Valérie Bousson
SSSalim Si-Mohamed
Salim Si-Mohamed
DDDjamel Dabli
Djamel Dabli
The purpose of this study was to compare the spectral performance of three dual-energy CT (DECT) scanners and one photon-counting CT (PCCT) scanner on virtual monoenergetic images (VMIs) at low-energy levels and on iodine maps. A spectral phantom was scanned using one PCCT scanner and three different DECT scanners that included a rapid kV-switching CT (R-KVSCT), an ultrafast kV-switching (U-KVSCT) and a dual-layer CT (DLCT) scanner. Acquisitions were obtained with each CT system using classical abdominal and pelvic examination parameters, as well as a volume CT dose index at 11 mGy. VMI at 40/50/60/70 keV and iodine maps were reconstructed for each scanner. Noise power spectrum (NPS) and task-based transfer function (TTF) were evaluated. Detectability indexes (d') were computed to model the detection task of two contrast-enhanced lesions. Noise magnitude decreased from 40 to 70 keV for all DECT scanners and this decrease was greater for R-KVSCT (-80.0 ± 0.1 [standard deviation (SD)] %) and less pronounced for DLCT (-14.4 ± 0.8 [SD] %) scanners. The average NPS spatial frequency (fav) values decreased from 40 to 70 keV (0.26 to 0.17 mm-1) for R-KVSCT, increased for DLCT (0.18 to 0.25 mm-1) but were similar for U-KVSCT (0.19 ± 0.002 [SD] mm-1) and PCCT (0.21 ± [SD] 0.008 mm-1) scanner. For R-KVSCT and PCCT scanners, TTF at 50 % (f50) values increased from 40 to 70 keV for both inserts. For U-KVSCT and DLCT scanners, similar f50 values were found according to energy level for both inserts. For both contrast-enhanced lesions, d' values decreased from 40 to 70 keV for PCCT, DLCT and U-KVSCT scanners. For R-KVSCT scanner, d' values peaked at 60 keV. At 40 and 50 keV, the greatest d' values were found with DLCT and PCCT scanners. At 40 or 50 keV, the best combined results (objective and subjective assessments) are obtained with DLCT and PCCT scanners.