The paper addresses a problem of ballistic object tracking with the use of the cinetheodolite electro-optical tracking system. Electro-optical systems are applied for acquiring the trajectory data of missiles, satellites, and rockets used for delivery of satellites to their prevised orbits. Despite the importance of such systems and their applications, in the open literature there are no publications describing tracking algorithms processing data from cinetheodolites. The paper describes a model-based algorithm of estimation of position and parameters of target motion for such a system, developed by the authors. The model of the system, nonlinear both in its description of the target dynamics and the measurement equations, is presented in detail. The proposed algorithm of estimation is also described, and chosen simulation results are included in the paper. Furthermore, a comparison of the proposed estimation algorithm with other possible, but simpler algorithms is presented.
Pedestrian navigation in outdoor environments where global navigation satellite systems (GNSS) are unavailable is a challenging problem. Existing technologies that have attempted to address this problemoften require external reference signals or specialized hardware, the extra size,weight, power, and cost of which are unsuitable for many applications. This article presents a real-time, self-contained outdoor navigation application that uses only the existing sensors on a smartphone in conjunction with a preloaded digital elevation map. The core algorithm implements a particle filter, which fuses sensor data with a stochastic pedestrian motion model to predict the user’s position. The smartphone’s barometric elevation is then compared with the elevation map to constrain the position estimate. The system developed for this research was deployed on Android smartphones and tested in several terrains using a variety of elevation data sources. The results fromthese experiments showthe systemachieves positioning accuracies in the tens of meters that do not grow as a function of time
Scanning probe microscopy (SPM) is a broad family of diagnostic methods. Common restraint of SPM is only surficial interaction with specimen, especially troublesome in case of complex volumetric systems, e.g. microbial or microelectronic. Scanning thermal microscopy (SThM) overcomes that constraint, since thermal information is collected from broader space. We present transformer bridge-based setup for resistive nanoprobe-based microscopy. With low-frequency (LF) (approx. 1 kHz) detection signal bridge resolution becomes independent on parasitic capacitances present in the measurement setup. We present characterisation of the setup and metrological description—with resolution of the system 0.6 mK with sensitivity as low as 5 mV K−1. Transformer bridge setup brings galvanic separation, enabling measurements in various environments, pursued for purposes of molecular biology. We present results SThM measurement results of high-thermal contrast sample of carbon fibres in an epoxy resin. Finally, we analyse influence of thermal imaging on topography imaging in terms of information channel capacity. We state that transformer bridge-based SThM system is a fully functional design along with low driving frequencies and resistive thermal nanoprobes by Kelvin Nanotechnology.
25 February 2025 in IEEE Transactions on Instrumentation and Measurement
Scanning thermal microscopy methods typically utilize the Wheatstone bridge for temperature readout. In this paper, we present a small form-factor transformer bridge developed for investigating thermal properties through resistance change measurements. Compared to resistive bridges, this method allows galvanic separation between the system and sample, thereby enabling the measurement of biased samples. We present magnetic measurements of the nanocrystalline transformer core, including magnetization curve and permittivity, which are crucial for proper winding design. The characteristics of the fabricated transformers are presented, based on inductances and losses measurements. The response of the entire setup is assessed, and the equivalent circuits are discussed, which provides the system performance in terms of noise, sensitivity, and resolution. The voltage noise of the circuitry 1 μVRMS and thermal sensitivity of 5 mV/K yielded a theoretical limit of 0.6 mK for the temperature resolution. The proposed transformer bridge is intended for use in indirect thermal measurements in an in-house developed scanning thermal microscope.