Sebastian Onder

Sebastian Onder


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
AGAndreas Gsponer
Andreas Gsponer
SOSebastian Onder
Sebastian Onder
SGStefan Gundacker
Stefan Gundacker
JBJürgen Burin
Jürgen Burin
MKMatthias Knopf
Matthias Knopf
TBThomas Bergauer
Thomas Bergauer
Silicon carbide (SiC) has been widely adopted in the semiconductor industry, particularly in power electronics, because of its high temperature stability, high breakdown field, and fast switching speeds. Its wide bandgap makes it an interesting candidate for radiation-hard particle detectors in high-energy physics and medical applications. Furthermore, the high electron and hole drift velocities in 4H-SiC enable devices suitable for ultra-fast particle detection and timing applications. However, currently, the front-end readout electronics used for 4H-SiC detectors constitute a bottleneck in investigations of the charge carrier drift. To address these limitations, a high-frequency readout board with an intrinsic bandwidth of 10 GHz was developed. With this readout, the transient current signals of a 4H-SiC diode with a diameter of 141 μm and a thickness of 50 μm upon UV laser, alpha particle, and high-energy proton beam excitation were recorded. In all three cases, the electron and hole drift can clearly be separated, which enables the extraction of the charge carrier drift velocities as a function of the electric field. These velocities, directly measured for the first time, provide a valuable comparison to Monte Carlo-simulated literature values and constitute an essential input for TCAD simulations. Finally, a complete simulation environment combining TCAD, the Allpix2 framework, and SPICE simulations is presented, which is in good agreement with the measured data.

19 June 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SOSebastian Onder
Sebastian Onder
PGPhilipp Gaggl
Philipp Gaggl
JBJürgen Burin
Jürgen Burin
AGAndreas Gsponer
Andreas Gsponer
MKMatthias Knopf
Matthias Knopf
TBThomas Bergauer
Thomas Bergauer

13 September 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
MKMatthias Knopf
Matthias Knopf
AGAndreas Gsponer
Andreas Gsponer
MKMatthias Kausel
Matthias Kausel
SWSimon Waid
Simon Waid
SOSebastian Onder
Sebastian Onder
AHAlbert Hirtl
Albert Hirtl

1 January 2026 in Journal of Instrumentation
Verified
Journal Article
Open access
DRDaniel Radmanovac
Daniel Radmanovac
AGAndreas Gsponer
Andreas Gsponer
SWSimon Waid
Simon Waid
SOSebastian Onder
Sebastian Onder
MKMatthias Knopf
Matthias Knopf
TBThomas Bergauer
Thomas Bergauer
Silicon carbide (SiC) planar PiN diodes from two different manufacturers were irradiated with 252.7 MeV protons from a medical synchrotron. Over the course of two 8h irradiation shifts, the samples were exposed to increasing fluences ranging from 1.4 × 10 11 to 3.5 × 10 13 p + /cm 2 . Electrical characterizations, including IV and CV measurements, were performed both before and after irradiation using probe stations, and for selected samples even in-situ between fluence steps directly at the irradiation facility. The results show a gradual compensation of the effective epitaxial doping concentration with each incremental fluence step, observed as a reduction in capacitance before full depletion and confirmed by the extracted effective doping concentration. From these measurements, linear donor removal rates are determined for all sample groups, with values ranging from 4.2 cm -1 to 6.4 cm -1 . These findings provide a quantitative basis for understanding radiation-induced charge carrier removal in 4H-SiC devices and are relevant for predicting the performance and lifetime of future radiation-hard detector technologies, including 4H-SiC LGADs.

1 July 2026 in Journal of Instrumentation
Verified
Journal Article
Closed access
SWSimon Waid
Simon Waid
MKMatthias Knopf
Matthias Knopf
GMGiulio Magrin
Giulio Magrin
AHAlbert Hirtl
Albert Hirtl
SOSebastian Onder
Sebastian Onder
TBThomas Bergauer
Thomas Bergauer
Recent clinical evidence shows a correlation between LET and tumor control in carbon ion radiotherapy. This prompts the direct inclusion of LET into the treatment planning. Currently, LET is mainly extracted from simulations. Good clinical practice requires adopting measurement routines that correlate with LET, such as microdosimetry. In this work, we describe an ASIC for reading out microdosimeteric sensors. The ASIC is designed for input capacitances up to 3pF. It contains four readout channels, each with a different saturation charge ranging from 75fC to 3.2pC. In the 75fC range, at 1pF input capacitance and a shaping time of 1µs, the ASIC has an equivalent noise contribution (ENC) below 15e at ambient temperature. This low noise level is expected to enable new measurement possibilities, including the assessment of microdosimetric proton spectra in the low-LET region of the entrance channel, as well as studying the contribution of delta electrons.

1 October 2026 in Journal of Instrumentation
Verified
Journal Article
Open access
MKMatthias Knopf
Matthias Knopf
SWSimon Waid
Simon Waid
SGStefan Gundacker
Stefan Gundacker
SOSebastian Onder
Sebastian Onder
DRDaniel Radmanovac
Daniel Radmanovac
AHAlbert Hirtl
Albert Hirtl
Detector characterization and instrumentation testing are often performed at cyclotron and synchrotron facilities, many of which were originally developed for medical applications in cancer therapy. For particle physics experiments requiring a single-particle resolution, pileup can significantly degrade data quality, making precise knowledge of the beam time structure essential for selecting appropriate readout parameters. However, such information is often unavailable from the facilities and challenging to determine experimentally. Here, we report measurements of the spill time structure at two medical accelerator facilities using a silicon carbide (SiC) particle sensor coupled to a high-frequency readout system. Owing to its high carrier saturation velocity and the tolerance to large bias voltages, SiC is well suited for fast readout and measurements requiring precise timing. Using an analog readout circuit with 6 GHz bandwidth and custom SiC diodes, we characterize the micro-spill structure of both cyclotron and synchrotron beams on a sub-nanosecond timescale. The measured arrival-time distributions exhibit modulation with the accelerator RF frequencies, reflecting features of the extraction process. The resolved micro-spill structure enables quantitative estimation of pileup contributions and provides design constraints for future readout electronics. The presented results emphasize the importance of the characterization of the beam time-structure characterization for the development of precise readout systems.