Matthias Knopf

Mr. Matthias Knopf

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
AGAndreas Gsponer
Andreas Gsponer
MKMatthias Knopf
Matthias Knopf
PGPhilipp Gaggl
Philipp Gaggl
JBJürgen Burin
Jürgen Burin
SWSimon Waid
Simon Waid
TBThomas Bergauer
Thomas Bergauer

25 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
AGAndreas Gsponer
Andreas Gsponer
SOSebastian Onder
Sebastian Onder
SGStefan Gundacker
Stefan Gundacker
JBJürgen Burin
Jürgen Burin
MKMatthias Knopf
Matthias Knopf
TBThomas Bergauer
Thomas Bergauer
Silicon carbide (SiC) has been widely adopted in the semiconductor industry, particularly in power electronics, because of its high temperature stability, high breakdown field, and fast switching speeds. Its wide bandgap makes it an interesting candidate for radiation-hard particle detectors in high-energy physics and medical applications. Furthermore, the high electron and hole drift velocities in 4H-SiC enable devices suitable for ultra-fast particle detection and timing applications. However, currently, the front-end readout electronics used for 4H-SiC detectors constitute a bottleneck in investigations of the charge carrier drift. To address these limitations, a high-frequency readout board with an intrinsic bandwidth of 10 GHz was developed. With this readout, the transient current signals of a 4H-SiC diode with a diameter of 141 μm and a thickness of 50 μm upon UV laser, alpha particle, and high-energy proton beam excitation were recorded. In all three cases, the electron and hole drift can clearly be separated, which enables the extraction of the charge carrier drift velocities as a function of the electric field. These velocities, directly measured for the first time, provide a valuable comparison to Monte Carlo-simulated literature values and constitute an essential input for TCAD simulations. Finally, a complete simulation environment combining TCAD, the Allpix2 framework, and SPICE simulations is presented, which is in good agreement with the measured data.

19 June 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SOSebastian Onder
Sebastian Onder
PGPhilipp Gaggl
Philipp Gaggl
JBJürgen Burin
Jürgen Burin
AGAndreas Gsponer
Andreas Gsponer
MKMatthias Knopf
Matthias Knopf
TBThomas Bergauer
Thomas Bergauer

1 July 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
MKMatthias Knopf
Matthias Knopf
SBSandra Barna
Sandra Barna
DRDaniel Radmanovac
Daniel Radmanovac
TBThomas Bergauer
Thomas Bergauer
AHAlbert Hirtl
Albert Hirtl
GMGiulio Magrin
Giulio Magrin
Objective. Microdosimetry investigates the energy deposition of ionizing radiation at microscopic scales, beyond the assessment capabilities of macroscopic dosimetry. This contributes to an understanding of the biological response in radiobiology, radiation protection and radiotherapy. Microdosimetric pulse height spectra are usually measured using an ionization detector in pulsed readout mode. This incorporates a charge-sensitive amplifier followed by a shaping network. At high particle rates, the pileup of multiple pulses leads to distortions in the recorded spectra. Especially for gas-based detectors, this is a significant issue, that can be reduced by using solid-state detectors with smaller cross-sectional areas and faster readout speeds. At particle rates typical for ion therapy, however, such devices will also experience pileup. Mitigation techniques often focus on avoiding pileup altogether, while post-processing approaches are rarely investigated. Approach. This work explores pileup effects in microdosimetric measurements and presents a stochastic resampling algorithm, allowing for offline simulation and correction of spectra. Initially it was developed for measuring neutron spectra with tissue equivalent proportional counters and is adapted for the use with solid-state microdosimeters in a clinical radiotherapy setting. Main results. The algorithm was tested on data acquired with solid-state microdosimeters at the MedAustron ion therapy facility. The successful simulation and reduction of pileup counts is achieved by establishing a limited number of parameters for a given setup. Significance. The presented results illustrate the potential of offline correction methods in situations where a direct pileup-free measurement is currently not practicable.

1 January 1998 in MRS Proceedings
Verified
Journal Article
Closed access
PDF file
ABA. Burchard
A. Burchard
MDM. Deicher
M. Deicher
DFD. Forkel-Wirth
D. Forkel-Wirth
MKMatthias Knopf
Matthias Knopf
RMR. Magerle
R. Magerle
TIThe Isolde-Collaboration
The Isolde-Collaboration

7 June 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SWSimon Waid
Simon Waid
PGPhilipp Gaggl
Philipp Gaggl
AGAndreas Gsponer
Andreas Gsponer
RTRichard Thalmeier
Richard Thalmeier
JBJürgen Burin
Jürgen Burin
TBThomas Bergauer
Thomas Bergauer