Xiaowei Feng

Mr. Xiaowei Feng


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2026 in Materials
Verified
Journal Article
Open access
PDF file
XFXiaowei Feng
Xiaowei Feng
BLBo Li
Bo Li
YZYan Zhang
Yan Zhang
YXYanrong Xu
Yanrong Xu
To improve night-time visibility of pavement markings, a long-afterglow road-marking coating was developed using strontium aluminate as the phosphorescent component. The influences of particle size (100–400 mesh), dosage (15–35 wt%), filler type, and coating thickness (200–600 μm) on optical behavior were systematically evaluated. The optimal formulation—200-mesh strontium aluminate at 30 wt%, titanium dioxides combined with ultrafine glass powder, and a thickness of 500 μm—achieved an initial brightness of 3.08 cd/m2 and maintained visible afterglow for more than 9 h. Durability tests confirmed satisfactory resistance to water, alkali, and abrasion, meeting the requirements of JTT 280-2022. Twinmotion simulations further demonstrated that when the coating brightness remains above 0.1 cd/m2, it provides effective visual guidance on unlit road sections, thereby enhancing night-time driving safety. This study verifies the feasibility of using long-afterglow coatings to improve road visibility and reduce night-time accident risks.

21 September 2026 in Photonics
Verified
Journal Article
Open access
PDF file
YLYong-Hao Liu
Yong-Hao Liu
ZJZhi-Jian Jia
Zhi-Jian Jia
CGChuan-Yu Guo
Chuan-Yu Guo
RRRui Rui
Rui Rui
XFXiaowei Feng
Xiaowei Feng
Ping XiangPing Xiang
Ping Xiang
The influence of mechanical noise on impact identification using fiber Bragg grating (FBG) accelerometers in complex environments remains insufficiently explored and quantitatively characterized. This study investigates how the intensity and propagation path of mechanical noise affect the output stability and impact-detection capability of a self-developed FBG accelerometer. A quantitative evaluation approach is established using wavelength-variation statistics, impact-response amplitude, and signal-to-noise ratio (SNR). Experimental results show that mechanical noise markedly increased the background wavelength fluctuation, with the maximum standard deviation reaching 16.71 pm, approximately 11 times the no-additional-noise value. By contrast, the RMS of the target impact response increased only slightly, from 0.0300 nm to 0.0353 nm, indicating that mechanical noise primarily affects baseline stability rather than the amplitude of the target impact response. Under the highest-intensity disturbance tested, the SNR remained at 22.98 dB, and the impact event remained distinguishable. The proposed multi-indicator approach provides a quantitative characterization of the FBG accelerometer response under different mechanical-noise conditions. A commercial 941B accelerometer was used as an external reference for sensitivity calibration, and its measurements were not used for direct performance comparison with the FBG accelerometer. The results provide experimental evidence of the impact-identification behavior of the proposed sensor under the investigated mechanical-noise conditions.

5 August 2026 in Symmetry
Verified
Journal Article
Open access
PDF file
JZJing-Cheng Zhou
Jing-Cheng Zhou
RRRui Rui
Rui Rui
XFXiaowei Feng
Xiaowei Feng
Yankewei XiaoYankewei Xiao
Yankewei Xiao
JZJin-Kui Zhang
Jin-Kui Zhang
Ping XiangPing Xiang
Ping Xiang
Internal responses of multilayer pavement structures are difficult to characterize using surface-based inspection alone. This study investigates a scaled multilayer pavement model instrumented with embedded quasi-distributed fiber Bragg grating (FBG) sensing lines to obtain baseline internal strain responses and FBG-derived relative vertical displacement distributions under controlled loading. Central single-point stepwise loading, symmetric two-point loading, and asymmetric two-point loading were applied, and FBG wavelength responses were converted into temperature-compensated strain and then into line-wise relative vertical displacement through strain–curvature conversion, curvature integration, and linear baseline correction. During loading, the ambient temperature ranged from 22.70 to 23.40 °C, and the maximum relative shift of the T-sensor was 0.008297 nm. Under 686 N central loading, SAL1 reached a maximum temperature-compensated strain of 1459.39 με and a maximum relative vertical displacement of 1.079 mm, whereas SAL2 reached 793.13 με and 0.583 mm. Under approximately 490 N asymmetric two-point loading, SAT2 reached 1699.48 με and 0.761 mm. Soil-base responses were substantially lower. Because no independent displacement measurement was acquired, the reconstructed quantity is interpreted as an FBG-derived relative deformation measure rather than an absolute displacement. The results establish intact baseline data for future, separately validated comparisons with abnormal conditions.