Chiedza Hwata

Ms. Chiedza Hwata

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2024 in Medicine
Verified
Journal Article
Open access
CHChiedza Hwata
Chiedza Hwata
OGOmar Gatera
Omar Gatera
NRNicola Ritsch
Nicola Ritsch
TUTherese Meng Uwiragiye
Therese Meng Uwiragiye
GRGerard RUSHINGABIGWI
Gerard RUSHINGABIGWI
DNDaniel Msc Nsengiyera
Daniel Msc Nsengiyera
Accuracy and reliability of medical device measurements are essential for high-quality healthcare delivery. Electromagnetic compatibility (EMC) is 1 of the conditions that can be monitored when managing electronic and wireless medical devices in hospitals. Noncompliance with EMC can lead to electromagnetic interference (EMI), risking catastrophic failures, especially in vital sign devices such as defibrillators and pacemakers, and potentially irreversible harm to patients’ health. This study assessed the knowledge of biomedical engineers and technicians regarding EMC and EMI in hospital devices and their effects. It also examines how hospitals manage biomedical equipment and the frequency of wireless communication usage. This study utilized an anonymous questionnaire administered to 35 biomedical personnel in Rwanda district hospitals. Face-to-face interviews were used for data collection. SPSS was used to analyze the data through descriptive analyses statistically, and a regression model was designed to evaluate the impact of electromagnetic compatibility and interference on medical device management (MDM). A statistical significance of 0.05 was assumed. The regression model predicted MDM with a significance level of 0.009 based on ANOVA values. A Pearson’s correlation test was also performed for the model. The results indicated an inverse relationship of −0.470 for EMI against MDM and −0.469 for EMC against MDM. A total of 24 (68.6%) respondents were unaware of electromagnetic compatibility/interference issues and 11 (31.4%) were familiar with it. All 35 respondents indicated that maintenance is currently being performed on medical devices. High usage of wireless devices, for professional and personal purposes is highlighted. Based on the results, both electromagnetic compatibility and understanding of interference influenced MDM. To ensure optimal medical device performance and improve hospital safety, we recommend continuous monitoring of medical device electromagnetic compatibility. Additionally, EMC/EMI awareness training can be incorporated into on-the-job training programs for biomedical staff members.

20 November 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CHChiedza Hwata
Chiedza Hwata
GRGerard RUSHINGABIGWI
Gerard RUSHINGABIGWI
OGOmar Gatera
Omar Gatera
DMDidacienne Mukalinyigira
Didacienne Mukalinyigira
CTCelestin Twizere
Celestin Twizere
Diego Peluffo-OrdóñezDiego Peluffo-Ordóñez
Diego Peluffo-Ordóñez
Electromagnetic compatibility is the capability of electrical and electronic equipment to function properly around devices radiating electromagnetic energy, without mutual disturbance. Hospital environments contain numerous devices operating simultaneously and sharing resources. Undetected electromagnetic interference can cause medical devices’ malfunctions, exposing patients and staff. Traditional monitoring is time-consuming and relies on expert interpretation. An Internet of Things-enabled embedded system architecture for remote and real-time monitoring of electromagnetic fields from medical devices is proposed. It integrates frequency probes, a Raspberry Pi 4, and a communication module. A three-month study conducted at Muhima District Hospital, Kigali, Rwanda, demonstrated the system’s effectiveness in monitoring electromagnetic field levels and cloud transmission. The signals were benchmarked against International Electrotechnical Commission and Rwanda Standards Board standards. Alerts are triggered when thresholds are exceeded, with results plotted on website and mobile interfaces. Emissions were highest at noon when the equipment was most active and lower after 1:30 PM, indicating reduced activity. The sample recorded statistics of electric fields include mean (1.0028), minimum (0.7228), and maximum (1.3515). Among the five filters evaluated, the Savitzky–Golay performed better, with MSE (0.235) and SNR (9.308). A 412 ms average latency and 24 h operation was achieved, offering a portable solution for hospital safety and equipment optimization.