Celestin Twizere

Celestin Twizere

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2024
Verified
Conference Paper
Open access
FBFabien Bulonza Baseme
Fabien Bulonza Baseme
DHDamien Hanyurwimfura
Damien Hanyurwimfura
CTCelestin Twizere
Celestin Twizere
Road incidents caused by driver distractions (such as phone usage), drunkenness, and excessive speed constitute significant dangers to public safety in Rwanda. A comprehensive study of the design and implementation of an AI and IoT-based system for accident detection, prevention, and enhanced emergency response is presented in this article as one of the solutions to the problem. Using Raspberry Pi microcontroller as the central server, the system incorporates several sensors and actuators connected to ESP8266, including GPS Gn801 GPS Glonass dual mode for speed detection and car localization, MQ3 alcohol gas sensor SEN42, R16 for alcohol detection, ADXL335-3 Axis compass accelerometer GY-6l for car movement changes. In addition, a Raspberry Pi 4Bl3B 5MP fisheye night vision focal camera is integrated into the system to detect driver distractions such as phone usage while driving. Sophisticated machine learning and artificial intelligence (AI) algorithms, with a specific focus on Convolutional Neural Networks (CNNs), were utilized to identify instances of driver distraction and facilitate real-time monitoring and alert systems. By leveraging on edge and cloud computing to process, store and analyze data, the system guarantees efficient and impactful correspondence with emergency response teams. Our objective is to contribute to the domain of road safety by developing an efficient solution for emergency response and accident prevention in Rwanda. Our primary focus is on our distinctive contribution, which is to address driver distraction monitoring and real-time reporting to a person in charge in hospital and police in an innovative manner. This addresses a crucial aspect that is currently not sufficiently addressed by other solutions in the field. The study's findings demonstrate the accuracy of the integrated IoT sensors in accurately detecting accidents, speed, monitoring alcohol consumption, and identifying distractions, specifically phone usage. A remarkable 86-100% accuracy is attained by Custom Convolutional Neural Networks (CNNs) when it comes to identifying driver distractions. The combination of edge and cloud computing guarantees timely and effective communication with emergency response teams. This study highlights the critical role that technology plays in improving road safety by proposing a technologically advanced solution for emergency response and accident prevention in Rwanda. The capabilities of the system to monitor in real-time and its efficacy in accident detection and prevention demonstrate its potential to make a substantial impact on the field of road safety.

27 December 2024 in Medicine
Verified
Journal Article
Open access
CHChiedza Hwata
Chiedza Hwata
OGOmar Gatera
Omar Gatera
NRNicola Ritsch
Nicola Ritsch
TUTherese Meng Uwiragiye
Therese Meng Uwiragiye
GRGerard RUSHINGABIGWI
Gerard RUSHINGABIGWI
DNDaniel Msc Nsengiyera
Daniel Msc Nsengiyera
Accuracy and reliability of medical device measurements are essential for high-quality healthcare delivery. Electromagnetic compatibility (EMC) is 1 of the conditions that can be monitored when managing electronic and wireless medical devices in hospitals. Noncompliance with EMC can lead to electromagnetic interference (EMI), risking catastrophic failures, especially in vital sign devices such as defibrillators and pacemakers, and potentially irreversible harm to patients’ health. This study assessed the knowledge of biomedical engineers and technicians regarding EMC and EMI in hospital devices and their effects. It also examines how hospitals manage biomedical equipment and the frequency of wireless communication usage. This study utilized an anonymous questionnaire administered to 35 biomedical personnel in Rwanda district hospitals. Face-to-face interviews were used for data collection. SPSS was used to analyze the data through descriptive analyses statistically, and a regression model was designed to evaluate the impact of electromagnetic compatibility and interference on medical device management (MDM). A statistical significance of 0.05 was assumed. The regression model predicted MDM with a significance level of 0.009 based on ANOVA values. A Pearson’s correlation test was also performed for the model. The results indicated an inverse relationship of −0.470 for EMI against MDM and −0.469 for EMC against MDM. A total of 24 (68.6%) respondents were unaware of electromagnetic compatibility/interference issues and 11 (31.4%) were familiar with it. All 35 respondents indicated that maintenance is currently being performed on medical devices. High usage of wireless devices, for professional and personal purposes is highlighted. Based on the results, both electromagnetic compatibility and understanding of interference influenced MDM. To ensure optimal medical device performance and improve hospital safety, we recommend continuous monitoring of medical device electromagnetic compatibility. Additionally, EMC/EMI awareness training can be incorporated into on-the-job training programs for biomedical staff members.

20 November 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CHChiedza Hwata
Chiedza Hwata
GRGerard RUSHINGABIGWI
Gerard RUSHINGABIGWI
OGOmar Gatera
Omar Gatera
DMDidacienne Mukalinyigira
Didacienne Mukalinyigira
CTCelestin Twizere
Celestin Twizere
Diego Peluffo-OrdóñezDiego Peluffo-Ordóñez
Diego Peluffo-Ordóñez
Electromagnetic compatibility is the capability of electrical and electronic equipment to function properly around devices radiating electromagnetic energy, without mutual disturbance. Hospital environments contain numerous devices operating simultaneously and sharing resources. Undetected electromagnetic interference can cause medical devices’ malfunctions, exposing patients and staff. Traditional monitoring is time-consuming and relies on expert interpretation. An Internet of Things-enabled embedded system architecture for remote and real-time monitoring of electromagnetic fields from medical devices is proposed. It integrates frequency probes, a Raspberry Pi 4, and a communication module. A three-month study conducted at Muhima District Hospital, Kigali, Rwanda, demonstrated the system’s effectiveness in monitoring electromagnetic field levels and cloud transmission. The signals were benchmarked against International Electrotechnical Commission and Rwanda Standards Board standards. Alerts are triggered when thresholds are exceeded, with results plotted on website and mobile interfaces. Emissions were highest at noon when the equipment was most active and lower after 1:30 PM, indicating reduced activity. The sample recorded statistics of electric fields include mean (1.0028), minimum (0.7228), and maximum (1.3515). Among the five filters evaluated, the Savitzky–Golay performed better, with MSE (0.235) and SNR (9.308). A 412 ms average latency and 24 h operation was achieved, offering a portable solution for hospital safety and equipment optimization.

1 October 2017
Verified
Conference Paper
Closed access
RMRchard Musabe
Rchard Musabe
VUV. Mugongo Ushindi
V. Mugongo Ushindi
SNSaid Rutabayiro Ngoga
Said Rutabayiro Ngoga
CTCelestin Twizere
Celestin Twizere
GBGaurav Bajpai
Gaurav Bajpai
Recent research has been focused on development of models to enhance the resources allocated to Device to Device Communication (D2D) within LTE-A cellular network, which is considered as promising technology for improving network throughput, spectrum efficiency and transmission delay. The availability of huge number of smart phone at affordable price has increase cellular data traffic, generated by data sharing applications. Therefore, it is of critical importance to achieve efficient throughput in LTE-A networks. In this paper, we propose the possible solution to improve this throughput by analyzing and simulating a model to enable multiple concurrent D2D pairs in evolution NBs. We first evaluate mathematic model to enhance the resource allocated to D2D users. Second, we simulate D2D communication scenario in LTE-Advanced network using network simulator version 3 (NS-3) under Ubuntu environment. Throughput was measured by taking into consideration control overhead. We also investigate the throughput at high layer the Packet Data Convergence Protocol (PDCP), which is above the Radio Link Control (RLC) layer. The results show that there are benefit in channel capacity when LTE-A users are used together with multiple D2D pairs.

1 December 2019
Verified
Conference Paper
Closed access
GRGerard Rushingabigwi
Gerard Rushingabigwi
LSL. G. Sun
L. G. Sun
CTCelestin Twizere
Celestin Twizere
PNPhilibert Nsengiyumva
Philibert Nsengiyumva
LSL. Sibomana
L. Sibomana
YHY. X. He
Y. X. He
Both the antenna miniaturization and bandwidth account for recent trends in designing modern antennas. This research is about the design of an ultra-wideband (UWB) planar monopole antenna, examining the specific absorption rate (SAR) induced by that antenna on a simplified human head model. The motives of the research are to miniaturize the antenna, targeting the UWB performance with minimized electromagnetic interference with the human brain fluid. An UWB small monopole antenna was designed, manufactured and tested (as a prototype); both the SAR and the electric field were simulated on a basic human head model. During the design process, as the antenna is grounded on one side, the performance is enhanced through impedance matching with the feed; electromagnetic (EM) far-field is strengthened too. Results from the grounded and ungrounded models at 3 GHz helped on the final prototype selection. A grounded monopole was selected, manufactured and the measured results proved the correctness of simulation results. The existing works in this area showed that computer simulation is a reliable method in studying electromagnetic radiation effects: sizing parameters and design properties are flexibly changed in simulation software. For main results, apart from the manufactured and tested prototype, the nearly zero SAR was achieved by simulation using the highfrequency structure simulator (HFSS) as a software tool; the brain fluid was directly placed in the main radiation near field beam of the antenna. The EM interference was studied on the modeled head and brain, in this research work; however, the same interference seriously affects the body’s organs which contain a big quantity of fluid, such as the heart, the cheeks, etc. Therefore, both the users and manufacturers of EM energy radiating devices are recommended to refer to their SAR design specifications before utilization, especially when those devices are intended to be used in closeness with the human body.

17 December 2025 in JMIR Research Protocols
Verified
Journal Article
Open access
ANAurore Nishimwe
Aurore Nishimwe
JGJuliette Gasana
Juliette Gasana
RMRegine Mugeni
Regine Mugeni
CTCelestin Twizere
Celestin Twizere
Eric HITIMANAEric HITIMANA
Eric HITIMANA
MTMarc Twagirumukiza
Marc Twagirumukiza
Background: Effective blood pressure (BP) monitoring is vital for the management of hypertension, allowing timely adjustments in treatment. This study focuses on the development and implementation of an innovative, locally designed eHealth technology, the HeartCare@Home system, to enhance the control and management of hypertension in outpatient noncommunicable disease (NCD) clinics in Rwanda. The HeartCare@Home system comprises a mobile health app that incorporates rapid SMS technology, an integrated dashboard for signal reception at the clinic office level, and a clinical decision support algorithm. Objective: This study aims to assess the clinical efficacy, feasibility, and acceptability of a novel eHealth technology, the HeartCare@Home system, that uses home and clinic-based automated BP monitoring with real-time management of elevated BP in an outpatient NCD clinic in Rwanda. Methods: This pilot study will use an interventional design with a crossover approach to test the clinical efficacy of the HeartCare@Home system at the NCD clinic of Kibagabaga District Hospital. A total of 140 patients with hypertension will take part in the study. All enrolled patients will be allocated to either the interventional group or the standard of care group. The follow-up for each group will be 6 months (3 months in each group follow-up). The data for the intervention group will be generated by our mobile health app, while data for the control group (standard care) will be retrieved from usual patient files at the NCD clinic. Data extraction sheets will be used for standard care data retrieval. The Feasibility of Intervention Measure and Acceptability of Intervention Measure tools will be used to cross-sectionally evaluate the feasibility and acceptability of the HeartCare@Home system. Data will be summarized with descriptive statistics. A paired sample 2-tailed t test will be used to test for differences between the pre- and postintervention records for hypertension control. Results: This study will yield a technical infrastructure, the HeartCare@Home system, to support the control and management of hypertension in outpatient NCD clinics. It will introduce a new model of health care delivery through innovative technology that enables home-based BP monitoring. This will offer a unique technology to enable elevated BP control and timely hypertension management and will also ensure a real-time communication linkage between patients and the appropriate level of care. Furthermore, the findings from the assessment of the clinical efficacy, feasibility, and acceptability of the HeartCare@Home system will inform possible scalability of the system to more NCD clinics. The study is currently in the implementation stage. Conclusions: The HeartCare@Home project will address the important gap of low BP control rates in patients with hypertension, which has contributed to delayed consultations and increased cardiovascular mortality. Such eHealth technology infrastructure may also be scalable to other settings. International Registered Report Identifier (IRRID): DERR1-10.2196/66211