The mechanical response of a tendon to load is strictly related to its complex and highly organized hierarchical structure, which ranges from the nano- to macroscale. In a broader context, the mechanical properties of tendons during tensile tests are affected by several distinct factors, due in part to tendon nature (anatomical site, age, training, injury, etc.) but also depending on the experimental setup and settings. This work aimed to present a systematic review of the mechanical properties of tendons reported in the scientific literature by considering different anatomical regions in humans and several animal species (horse, cow, swine, sheep, rabbit, dog, rat, mouse, and foal). This study was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) method. The literature research was conducted via Google Scholar, PubMed, PicoPolito (Politecnico di Torino’s online catalogue), and Science Direct. Sixty studies were selected and analyzed. The structural and mechanical properties described in different animal species were reported and summarized in tables. Only the results from studies reporting the strain rate parameter were considered for the comparison with human tendons, as they were deemed more reliable. Our findings showed similarities between animal and human tendons that should be considered in biomechanical evaluation. An additional analysis of the effects of different strain rates showed the influence of this parameter.
11 May 2023 in Biomechanics and Modeling in Mechanobiology
The interest in the properties of animal soft tissues is often related to the desire to find an animal model to replace human counterparts due to the unsteady availability of human tissues for experimental purposes. Once the most appropriate animal model is identified, it is possible to carry out ex-vivo and in-vivo studies for the repair of ligamentous tissues and performance testing of replacement and support healing devices. This work aims to present a systematic review of the mechanical properties of ligaments reported in the scientific literature by considering different anatomical regions in humans and several animal species. This study was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) method. Moreover, considering the lack of a standard protocol for preconditioning of tissues, this aspect is also addressed. Ninety-six studies were selected for the systematic review and analysed. The mechanical properties of different animal species are reported and summarised in tables. Only results from studies reporting the strain rate parameter were considered for comparison with human ligaments, as they were deemed more reliable. Elastic modulus, ultimate tensile stress, and ultimate strain properties are graphically reported identifying the range of values for each animal species and to facilitate comparison between values reported in the scientific literature in animal and human ligaments. Useful similarities between the mechanical properties of swine, cow, and rat and human ligaments have been found.
Present and future anatomical models for biomedical applications will need bio-mimicking three-dimensional (3D)-printed tissues. These would enable, for example, the evaluation of the quality-performance of novel devices at an intermediate step between ex-vivo and in-vivo trials. Nowadays, PolyJet technology produces anatomical models with varying levels of realism and fidelity to replicate organic tissues. These include anatomical presets set with combinations of multiple materials, transitions, and colors that vary in hardness, flexibility, and density. This study aims to mechanically characterize multi-material specimens designed and fabricated to mimic various bio-inspired hierarchical structures targeted to mimic tendons and ligaments. A Stratasys® J750™ 3D Printer was used, combining the Agilus30™ material at different hardness levels in the bio-mimicking configurations. Then, the mechanical properties of these different options were tested to evaluate their behavior under uni-axial tensile tests. Digital Image Correlation (DIC) was used to accurately quantify the specimens’ large strains in a non-contact fashion. A difference in the mechanical properties according to pattern type, proposed hardness combinations, and matrix-to-fiber ratio were evidenced. The specimens V, J1, A1, and C were selected as the best for every type of pattern. Specimens V were chosen as the leading combination since they exhibited the best balance of mechanical properties with the higher values of Modulus of elasticity (2.21 ± 0.17 MPa), maximum strain (1.86 ± 0.05 mm/mm), and tensile strength at break (2.11 ± 0.13 MPa). The approach demonstrates the versatility of PolyJet technology that enables core materials to be tailored based on specific needs. These findings will allow the development of more accurate and realistic computational and 3D printed soft tissue anatomical solutions mimicking something much closer to real tissues.
Stapling devices have emerged as a widespread and effective option for soft tissue surgery, offering promising outcomes for patients by reducing complication rates and surgery time. This review aims to provide an exhaustive analysis of commercially available alternatives in the market, incorporating insights from market analysis, patent landscape, and the existing literature. The main focus lies in identifying and evaluating the most widely adopted and innovative stapling devices, including linear, linear cutting, circular, and powered staplers. In addition, this review delves into the realm of bioabsorbable staples, exploring the materials utilized and the surgical fields where these advanced staples find applications. To facilitate easy comprehension, the gathered information is presented in tables, highlighting the essential parameters for each stapling device. This comprehensive research about stapling devices is intended to aid healthcare practitioners and researchers in making informed decisions when choosing the most appropriate instrument for specific surgical procedures.
Musculoskeletal injuries often occur when performing motocross; almost half of the overall ligamentous injuries (42%) are knee ligaments injuries. Lesions can be greatly reduced with knee braces. Commercial knee braces are expected to oppose and limit unwanted and potentially harmful movements such as hyperextension and excessive rotation of the knee joint. However, this aspect has not been fully investigated from a biomechanical point of view. This would require proper Finite Element Modelling (FEM) and Analysis (FEA). However, to perform FEA and evaluate the efficacy of the brace simulating sportive conditions, numerical models need to be built. It requires a dedicated setup and several preprocessing steps, for which no industrial standard or widely accepted better practise is available as of today. Firstly, the brace and the lower limb are scanned using a 3D scanner. The geometry is reconstructed using reverse engineering techniques. These allow us to obtain a smooth, reliable 3D model starting from the points cloud acquired during scanning. A lower limb model was created using a mixed approach, combining MRI data and 3D scanning. Finally, a simulation of the impact condition after a jump using the developed model was carried out.
Background: Nowadays, flexor hand tendon repair represents a clinical need, and new suture patterns or devices are commonly tested on animal surrogates. Considering the literature, the most frequently adopted animal models for testing are the equivalent tendons taken from porcine specimens. The constitutive modelling of these tendons could open the way to the numerical testing of new repair techniques and the development of digital twins, reducing the use of animal models. Methods: Uniaxial tensile stress-relaxation tests at different strain levels during the loading and unloading phases on porcine tendons were performed. Constitutive formulations based on the assumptions of incompressible and nearly incompressible materials were evaluated. Results: The experimental data were evaluated considering the relaxation tests at different strain levels during both the loading and unloading phases. The experimental tests were used for the material parameter calibration of both models. Conclusions: The stress-relaxation tests conducted at different strain levels during the loading phase showed good agreement with previous findings reported in the literature. Both constitutive model formulations provided a reliable approximation for numerical simulations.