Mariana Rodriguez Reinoso

Prof. Mariana Rodriguez Reinoso

Politecnico di Torino, corso duca degli Abruzzi 24
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2021 in Applied Mechanics
Verified
Journal Article
Open access
PDF file
Carmela RiccioCarmela Riccio
Carmela Riccio
Marco CiveraMarco Civera
Marco Civera
OROliver Grimaldo Ruiz
Oliver Grimaldo Ruiz
PPPerla Pedullà
Perla Pedullà
MRMariana Rodriguez Reinoso
Mariana Rodriguez Reinoso
Cecilia SuraceCecilia Surace
Cecilia Surace
Different mechanical properties characterise the materials of 3D printed components, depending on the specific additive manufacturing (AM) process, its parameters, and the post-treatment adopted. Specifically, stereolithography (SLA) uses a photopolymerisation technique that creates solid components through selective solidification. In this study, 72 specimens were 3D printed using 12 commercial-grade methacrylate resins and tested under uniaxial tensile loads. The resin specimens were evaluated before and after curing. The recommended cure temperature and time were followed for all materials. The stress-strain curves measured during the testing campaign were evaluated in terms of maximum tensile strength, Young’s modulus, ductility, resilience, and toughness. The results reveal that the curing process increases the material stiffness and resistance to tensile loads. However, it was found that the curing process generally reduces the plasticity of the resins, causing a more or less marked brittle behaviour. This represents a potential limitation to the use of SLA 3D printing for structural elements which require some plasticity to avoid dangerous sudden failures.

28 February 2022 in Processes
Verified
Journal Article
Open access
PDF file
VBVito Burgio
Vito Burgio
Marco CiveraMarco Civera
Marco Civera
MRMariana Rodriguez Reinoso
Mariana Rodriguez Reinoso
EPElena Pizzolante
Elena Pizzolante
SPSimona Prezioso
Simona Prezioso
Cecilia SuraceCecilia Surace
Cecilia Surace
The mechanical response of a tendon to load is strictly related to its complex and highly organized hierarchical structure, which ranges from the nano- to macroscale. In a broader context, the mechanical properties of tendons during tensile tests are affected by several distinct factors, due in part to tendon nature (anatomical site, age, training, injury, etc.) but also depending on the experimental setup and settings. This work aimed to present a systematic review of the mechanical properties of tendons reported in the scientific literature by considering different anatomical regions in humans and several animal species (horse, cow, swine, sheep, rabbit, dog, rat, mouse, and foal). This study was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) method. The literature research was conducted via Google Scholar, PubMed, PicoPolito (Politecnico di Torino’s online catalogue), and Science Direct. Sixty studies were selected and analyzed. The structural and mechanical properties described in different animal species were reported and summarized in tables. Only the results from studies reporting the strain rate parameter were considered for the comparison with human tendons, as they were deemed more reliable. Our findings showed similarities between animal and human tendons that should be considered in biomechanical evaluation. An additional analysis of the effects of different strain rates showed the influence of this parameter.

11 May 2023 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
VBVito Burgio
Vito Burgio
SCS. Casari
S. Casari
MMM. Milizia
M. Milizia
FSF. Sanna
F. Sanna
GSG. Spezia
G. Spezia
Cecilia SuraceCecilia Surace
Cecilia Surace
The interest in the properties of animal soft tissues is often related to the desire to find an animal model to replace human counterparts due to the unsteady availability of human tissues for experimental purposes. Once the most appropriate animal model is identified, it is possible to carry out ex-vivo and in-vivo studies for the repair of ligamentous tissues and performance testing of replacement and support healing devices. This work aims to present a systematic review of the mechanical properties of ligaments reported in the scientific literature by considering different anatomical regions in humans and several animal species. This study was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) method. Moreover, considering the lack of a standard protocol for preconditioning of tissues, this aspect is also addressed. Ninety-six studies were selected for the systematic review and analysed. The mechanical properties of different animal species are reported and summarised in tables. Only results from studies reporting the strain rate parameter were considered for comparison with human ligaments, as they were deemed more reliable. Elastic modulus, ultimate tensile stress, and ultimate strain properties are graphically reported identifying the range of values for each animal species and to facilitate comparison between values reported in the scientific literature in animal and human ligaments. Useful similarities between the mechanical properties of swine, cow, and rat and human ligaments have been found.

28 June 2022 in Polymers
Verified
Journal Article
Open access
PDF file
OROliver Grimaldo Ruiz
Oliver Grimaldo Ruiz
MRMariana Rodriguez Reinoso
Mariana Rodriguez Reinoso
EIElena Ingrassia
Elena Ingrassia
FVFederico Vecchio
Federico Vecchio
FMFilippo Maniero
Filippo Maniero
Cecilia SuraceCecilia Surace
Cecilia Surace
Present and future anatomical models for biomedical applications will need bio-mimicking three-dimensional (3D)-printed tissues. These would enable, for example, the evaluation of the quality-performance of novel devices at an intermediate step between ex-vivo and in-vivo trials. Nowadays, PolyJet technology produces anatomical models with varying levels of realism and fidelity to replicate organic tissues. These include anatomical presets set with combinations of multiple materials, transitions, and colors that vary in hardness, flexibility, and density. This study aims to mechanically characterize multi-material specimens designed and fabricated to mimic various bio-inspired hierarchical structures targeted to mimic tendons and ligaments. A Stratasys® J750™ 3D Printer was used, combining the Agilus30™ material at different hardness levels in the bio-mimicking configurations. Then, the mechanical properties of these different options were tested to evaluate their behavior under uni-axial tensile tests. Digital Image Correlation (DIC) was used to accurately quantify the specimens’ large strains in a non-contact fashion. A difference in the mechanical properties according to pattern type, proposed hardness combinations, and matrix-to-fiber ratio were evidenced. The specimens V, J1, A1, and C were selected as the best for every type of pattern. Specimens V were chosen as the leading combination since they exhibited the best balance of mechanical properties with the higher values of Modulus of elasticity (2.21 ± 0.17 MPa), maximum strain (1.86 ± 0.05 mm/mm), and tensile strength at break (2.11 ± 0.13 MPa). The approach demonstrates the versatility of PolyJet technology that enables core materials to be tailored based on specific needs. These findings will allow the development of more accurate and realistic computational and 3D printed soft tissue anatomical solutions mimicking something much closer to real tissues.

21 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LLLucrezia Lazzarini
Lucrezia Lazzarini
Marco CiveraMarco Civera
Marco Civera
VBVito Burgio
Vito Burgio
MRMariana Rodriguez Reinoso
Mariana Rodriguez Reinoso
PAPaola Antonaci
Paola Antonaci
Cecilia SuraceCecilia Surace
Cecilia Surace
Musculoskeletal injuries often occur when performing motocross; almost half of the overall ligamentous injuries (42%) are knee ligaments injuries. Lesions can be greatly reduced with knee braces. Commercial knee braces are expected to oppose and limit unwanted and potentially harmful movements such as hyperextension and excessive rotation of the knee joint. However, this aspect has not been fully investigated from a biomechanical point of view. This would require proper Finite Element Modelling (FEM) and Analysis (FEA). However, to perform FEA and evaluate the efficacy of the brace simulating sportive conditions, numerical models need to be built. It requires a dedicated setup and several preprocessing steps, for which no industrial standard or widely accepted better practise is available as of today. Firstly, the brace and the lower limb are scanned using a 3D scanner. The geometry is reconstructed using reverse engineering techniques. These allow us to obtain a smooth, reliable 3D model starting from the points cloud acquired during scanning. A lower limb model was created using a mixed approach, combining MRI data and 3D scanning. Finally, a simulation of the impact condition after a jump using the developed model was carried out.

15 March 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VBVito Burgio
Vito Burgio
JBJanira Bei
Janira Bei
MRMariana Rodriguez Reinoso
Mariana Rodriguez Reinoso
Marco CiveraMarco Civera
Marco Civera
OROliver Grimaldo Ruiz
Oliver Grimaldo Ruiz
Nicola PugnoNicola Pugno
Nicola Pugno
Stapling devices have emerged as a widespread and effective option for soft tissue surgery, offering promising outcomes for patients by reducing complication rates and surgery time. This review aims to provide an exhaustive analysis of commercially available alternatives in the market, incorporating insights from market analysis, patent landscape, and the existing literature. The main focus lies in identifying and evaluating the most widely adopted and innovative stapling devices, including linear, linear cutting, circular, and powered staplers. In addition, this review delves into the realm of bioabsorbable staples, exploring the materials utilized and the surgical fields where these advanced staples find applications. To facilitate easy comprehension, the gathered information is presented in tables, highlighting the essential parameters for each stapling device. This comprehensive research about stapling devices is intended to aid healthcare practitioners and researchers in making informed decisions when choosing the most appropriate instrument for specific surgical procedures.