Narayan Prasad Patidar

Prof. Dr. Narayan Prasad Patidar


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2014 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
PPPriyanka Paliwal
Priyanka Paliwal
NPNarayan Prasad Patidar
Narayan Prasad Patidar
RNR.K. Nema
R.K. Nema

3 July 2020 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
ARArun Rathore
Arun Rathore
NPNarayan Prasad Patidar
Narayan Prasad Patidar
Hybrid renewable energy systems (RESs) with storage are gaining significant attention for off‐grid communities. Planning of reliability constrained social‐economic analysis is a combinatory optimisation problem. This work focuses on the reliability constrained optimisation of the levelized cost of energy (LCOE) of RES with the storage considering the cost of emission. Hybrid energy systems consist of photovoltaic (PV), wind turbine (WT) and diesel generator (DG) with storage. In this work, a systematic approach for determination of reliability constrained optimal combination of generating and storage technologies based on techno‐socio‐economic criteria has been developed. To evaluate the reliability and the expected generation from the individual unit, probabilistic production costing simulation has been performed using an analytical technique. The optimal sizing of RES with storage has been evaluated using particle swarm optimisation technique and tested on ten different cases. The combination of generation/storage technologies that fetch minimum LCOE while satisfying the reliability standards is chosen as the optimal configuration. Results show that a combination of PV, WT and pumped storage hydro is the best option to meet the energy requirements, with the least LCOE of 0.268 $/kW while satisfying reliability criteria. Further, an optimum generation expansion plan has also been determined for the aforementioned optimal configuration.

17 February 2023 in International Journal of Ambient Energy
Verified
Journal Article
Closed access
ARArun Rathore
Arun Rathore
AKAnupam Kumar
Anupam Kumar
NPNarayan Prasad Patidar
Narayan Prasad Patidar
Hybrid power systems (HPS) are appropriate for delivering steady and quality energy to an isolated area and have the possibility of decreasing pollutants. In this work, a hybrid model comprised of PV array, Wind turbine units, Diesel Generator and Battery Energy Storage. The suggested framework takes into account the intermittent nature of renewable resources in the simulation. The hourly data of site i.e. solar irradiance and wind speed have been modelled using Beta and Weibull probability distribution function. The suggested microgrid is optimized using HOMER software and Particle Swarm Optimization (PSO) technique for determining the optimal size of the system components and carrying out the cost assessment. The peak demand for the HPS is taken to be 60 kW, and the time-dependent load curve shape is modelled using IEEE RTS system. This study focuses on determining the optimal components size of the HPS with lowest levelized cost of energy (LCOE) while taking into account the time-dependent load profile of the Hatta village located in Damoh district, Madhya Pradesh, India. Reliability indicator(Loss of Power Supply Probability (LPSP)), Battery State of Charge (SOC), and other technical parameters are used as constraints in the planning of HPS. The analysis has been carried out for seven different combination of generating and storage unit, and the combination that achieves least LCOE after meeting all the constraints is selected as the optimal cases. The results shows that case 7 fetches minimum LCOE of 0.209 $/kWh for the selected site and the optimal PV, WT, and battery storage unit sizes are 172 kW, 78 kW, and 640 kWh, respectively. Results from the HOMER software have been verified by comparison with the PSO. Sensitivity analysis was also carried out by changing the component sizes close to their obtained values for analysing the optimal sizing results. Further, the effect of load growth on LCOE and LPSP is presented for the optimal configuration.

19 May 2024 in Cleaner Engineering and Technology
Verified
Journal Article
Open access
SNSonali R. Nandanwar
Sonali R. Nandanwar
NPNarayan Prasad Patidar
Narayan Prasad Patidar
SPSiddharth Panda
Siddharth Panda
JTJalpa Thakkar
Jalpa Thakkar
Mohan Lal KOLHEMohan Lal KOLHE
Mohan Lal KOLHE
The integration of Decentralized Energy Resources (DERs), Energy Storage Systems (ESS), and Electric Vehicles (EVs) into grid-connected networks presents a transformative paradigm in modern power systems. This article introduces a synergistic control framework tailored for optimizing frequency stability within grid-integrated distributed networks. The proposed approach leverages advanced control algorithms to orchestrate the dynamic interaction between DERs, ESS, and EVs, ensuring seamless operation and enhanced grid resilience. The effectiveness of the proposed control strategy is demonstrated in mitigating frequency deviations, thereby contributing to a more stable and reliable grid infrastructure. This article introduces a novel approach utilizing the Selfish Herd Optimization (SHO) algorithm to address this critical issue. Inspired by the self-preservation behavior observed in animal herding, the SHO algorithm is adapted to coordinate the operation of DERs with loads within a distributed network. By dynamically adjusting their output based on local frequency measurements, DERs collectively exhibit a self-organizing behavior, resulting in improved frequency stability. The SHO based PID controller is also proven to be far more effective at controlling frequency than the traditional PI controller. The findings underscore the potential of bio-inspired algorithms in enhancing the resilience of grid-integrated DER systems, offering a promising avenue for future grid control methodologies.

1 January 2006
Verified
Conference Paper
Closed access
NPNarayan Prasad Patidar
Narayan Prasad Patidar
JSJaydev Sharma
Jaydev Sharma
This paper presents case-based reasoning (CBR) technique, a novel approach for voltage security assessment in real time environment. The CBR is an artificial intelligence methodology; extract the information of voltage security from large sets of possible operating conditions of the power system, which are screened off-line by randomly varying the real and reactive loads at PQ buses. In real time environment, data-base may be created by keeping the record of operating states by state estimation. The severity of contingency for each case with respect to different contingencies (single line outages) is assessed by number of secure and insecure operating states, which is predicted by CBR. Security classes are defined by threshold value of maximum loadability margins, calculated using the continuation power flow analysis. The effectiveness of the proposed approach is tested on 30-Bus IEEE test system. The proposed method gives fast and accurate voltage security information for unknown patterns and it is found to be suitable for on-line applications at energy management systems.

1 January 2023 in IET Electrical Systems in Transportation
Verified
Journal Article
Open access
PDF file
TSTanmay Shukla
Tanmay Shukla
NPNarayan Prasad Patidar
Narayan Prasad Patidar
AAApsara Adhikari
Apsara Adhikari
This article presents a nonbridged isolated positive Cuk (NB‐IPCuk) converter‐based single‐stage battery charging system (SSBCS). The architecture of the suggested charger ensures the intrinsic advantage of power quality improvement in discontinuous current conduction (DCC) mode at the supply mains. The suggested NB‐IPCuk converter scheme has fewer components than other bridgeless/nonbridged Cuk converter schemes. This is because the NB‐IPCuk converter is a partial integration of two Cuk converters. The usage of the Cuk converter garnishes the system with input and output inductances, which lessens supply current harmonic distortion and, thus supply terminal low pass filter requirement is eradicated. The advantages of the NB‐IPCuk converter are the eradication of one inductor and multiple diodes (two back‐feeding diodes), which are generally used in NB converter configurations. In place of two separate inductors, the NB‐IPCuk converter uses a single secondary side output inductor. The usage of BL configuration of NB‐IPCuk converter eradicates the bridge rectifier (BR) stage, and thus, the BR‐associated losses also got eradicated. The NB‐IPCuk converter also garnishes the system with electrical isolation which adds to the safety standards of the system. DCC mode operation of the NB‐IPCuk converter is used in the present work. DCC mode requires lesser sensors in comparison to continuous current conduction mode. The abovementioned benefits of the NB‐IPCuk converter make the SSBCS system cheaper, compact, and more efficient. The detailed stability analysis (Bode diagram and pole‐zero map) and mathematics for the NB‐IPCuk converter are also included in the paper. The prototype and MATLAB/Simulink model of NB‐IPCuk converter‐based SSBCS system with DCC mode control has been built, and results of both prototype and MATLAB/Simulink are deployed to verify SSBCS system’s performance during dynamic and steady‐state conditions.