The capacitive voltage transformer (CVT) plays a critical role in power grid metering; however, over time, CVT measurement errors can become a prevalent issue. This study establishes an online detection method for CVT measurement errors utilizing a voltage online monitoring system and the maximum approximate coefficient growth rate (MACGR) method. First, a voltage online monitoring system integrated TV54A71 voltage sensors and a ZU3EG chip is designed. The TV54A71 voltage sensors and ZU3EG chip are respectively used to capture and deal the three-phase voltage on the CVT’s secondary side. Subsequently, the collected CVT secondary voltage is decomposed using the wavelet transform method in the monitoring system, and the MACGR of each phase is calculated to serve as a statistical index for CVT measurement errors. A kernel density statistical method is then applied to establish a measurement error threshold of 0.2%. The efficacy of the proposed MACGR method is validated through tests conducted using the CVT online test system of the China Electric Power Research Institute. The results indicate the ability of the MACGR method to accurately estimate CVT measurement errors. Furthermore, the designed monitoring system is assessed at a Xuzhou substation of the State Grid Corporation of China. The system consistently collects CVT secondary voltage accurately over an extended period. Employing the proposed MACGR method on the measured data confirms its effectiveness in estimating the measurement errors of CVT of the State Grid Corporation of China.
25 January 2021 in IEEE Transactions on Instrumentation and Measurement
Two-stage voltage transformer (VT) based on high-voltage excitation is usually less than 10 kV due to insulation limitation. To develop a two-stage VT with high-voltage excitation above 10 kV, this article designed two feasible structures. By calculating and comparing the lengths of the magnetic path, a better structural scheme was selected. The excitation winding and the precise ratio winding are in an “up-and-down” structure. This makes it work at a higher voltage possible. Moreover, a flexible compensation circuit was added to the secondary of this two-stage VT to acquire higher accuracy. Based on the principle, a 500/√3-kV two-stage VT has been developed. The half-symmetry summation method was used to calibrate this two-stage VT. The measurement results indicate that the voltage coefficient is very low. The error is (-2.2 to +3.1) μV/V for the ratio error and (-2.6 to -0.2) μrad for the phase displacement in the range of (20%-120%) rated voltage.
23 October 2024 in IET Science, Measurement & Technology
This paper proposes an online identification method utilizing phasor measurement unit (PMU) measurements, symmetric dot pattern (SDP) graphs, and the ResNet50‐L1 M model to facilitate the rapid identification of metering relative errors among interconnected capacitor voltage transformers (CVTs) in wide‐area substations within power systems. First, PMUs measured the three‐phase voltage data from interconnected CVTs across wide‐area substations. The amplitude differences of the three‐phase voltages were converted into Euclidean distances, which were then transformed into SDP graphs, with each type of metering relative error corresponding to a distinct SDP graph. The ResNet50‐L1 M model was established by integrating an L1 norm‐based attention mechanism into the ResNet50 architecture. This model was then trained on CVT SDP graphs representing various error states to develop an online error identification system. The effectiveness of the proposed method was evaluated based on data from the “Houshou transmission line” in Ningxia province, which connects the 330 kV Niushoushan substation and the 330 kV Houqiao substation operated by the State Grid Corporation of China. With 16 different error states tested, the model achieved an identification accuracy rate of 89.39%, demonstrating a notable improvement over other methods in comparative tests.
3 July 2018 in Journal of Electrical and Computer Engineering
One of the key issues of the accurate parameters analysis for the piecewise envelope current signal is to position the change point precisely. Discrete wavelet transform (DWT) modulus maxima method can detect change point, but the detection window of DWT will cause suspicious change point. Besides, the amount of calculated data is very large in actual process of envelope current signal. Therefore, in this paper, the envelope is used instead of the original sampling data for DWT so as to reduce the calculation amount. What is more, combined with the sliding dislocation window method, the change point can be located accurately and the pseudo-change point can be eliminated. The simulation results as well as the electric locomotive current and forging machine current examples show that it is feasible to detect the change point precisely through the proposed method, which provides possibilities for real-time online monitoring of change point.
17 July 2023 in IEEE Transactions on Instrumentation and Measurement
A two-stage voltage transformer (VT) with several rated transformer ratios and with a rated maximum voltage of 40 kV and a rated minimum voltage of 5 kV has been designed. To guarantee high accuracy over the full medium voltage range, the primary winding has been split into 4 primary windings, which can be configured in three different series and parallel connections. With five windings of the secondary, 15 different voltage ratios can be accomplished. This connection scheme, which is already used in older commercial standard VTs of the error class 0.02, achieves a very low effective output resistance, which in turn results in very small additional errors of less than 0.5·10 -6 due to the loading by the input of the transformer bridge. According to the measuring results, for all the 15 different ratios, the error is less than 20 μV/V for ratio error and 20 μrad for phase displacement.