Absorption systems are a sustainable solution as solar driven air conditioning devices in places with warm climatic conditions, however, the reliability of these systems must be improved. The absorbing component has a significant effect on the cycle performance, as this process is complex and needs efficient heat exchangers. This paper presents an experimental study of a bubble mode absorption in a plate heat exchanger (PHE)-type absorber with NH3-LiNO3 using a vapor distributor in order to increase the mass transfer at solar cooling operating conditions. The vapor distributor had a diameter of 0.005 m with five perforations distributed uniformly along the tube. Experiments were carried out using a corrugated plate heat exchanger model NB51, with three channels, where the ammonia vapor was injected in a bubble mode into the solution in the central channel. The range of solution concentrations and mass flow rates of the dilute solution were from 35 to 50% weight and 11.69 to 35.46 × 10−3 kg·s−1, respectively. The mass flow rate of ammonia vapor was from 0.79 to 4.92 × 10−3 kg·s−1 and the mass flow rate of cooling water was fixed at 0.31 kg·s−1. The results achieved for the absorbed flux was 0.015 to 0.024 kg m−2·s−1 and the values obtained for the mass transfer coefficient were in the order of 0.036 to 0.059 m·s−1. The solution heat transfer coefficient values were obtained from 0.9 to 1.8 kW·m−2·K−1 under transition conditions and from 0.96 to 3.16 kW·m−2·K−1 at turbulent conditions. Nusselt number correlations were obtained based on experimental data during the absorption process with the NH3-LiNO3 working pair.

28 December 2017 in Energies
Verified
Journal Article
Open access
PDF file
Jesus CerezoJesus Cerezo
Jesus Cerezo
RBRoberto Best
Roberto Best
JCJorge Chan
Jorge Chan
Rosenberg J RomeroRosenberg J Romero
Rosenberg J Romero
JHJorge I. Hernandez
Jorge I. Hernandez
Fernando LaraFernando Lara
Fernando Lara
The heat transfer in double pipe heat exchangers is very poor. This complicates its application in absorption cooling systems, however, the implementation of simple passive techniques should help to increase the heat and mass transfer mainly in the absorber. This paper carried out a simulation and its experimental comparison of a NH3-H2O bubble absorption process using a double tube heat exchanger with a helical screw static mixer in both central and annular sides. The experimental results showed that the absorption heat load per area is 31.61% higher with the helical screw mixer than the smooth tube. The theoretical and experimental comparison showed that the absorption heat load difference values were 28.0 and 21.9% for smooth tube and the helical mixer, respectively. These difference values were caused by the calculation of the log mean temperature difference in equilibrium conditions to avoid the overlap of solution temperatures. Therefore, the theoretical and experimental results should be improved when the absorption heat is included in the heat transfer equation or avoiding the operation condition when output is lower than input solution temperature.

5 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
YMYeudiel Garcíadealva Magos
Yeudiel Garcíadealva Magos
RBRoberto Best
Roberto Best
VEVICTOR HIGO GOMEZ ESPINOZA
VICTOR HIGO GOMEZ ESPINOZA
AVAlejandro Vargas
Alejandro Vargas
WRWilfrido Rivera
Wilfrido Rivera
J. Camilo Jiménez GarcíaJ. Camilo Jiménez García
J. Camilo Jiménez García
Automatic proportional integral derivative control techniques are applied in a single-stage solar absorption cooling system, showing 3.8 kW (~1 ton) cooling capacity, with a coefficient of performance of 0.6 and −4.1 °C evaporator cooling temperature. It is built with plate heat exchangers as main components, using ammonia–water as the working mixture fluid and solar collectors as the main source of hot water. Control tuning was verified with a dynamical simulation model for a solution regarding mass flow stability and temperature control in the solar absorption cooling system. The controller improved steady thermodynamic state and time response. According to experimental cooling temperatures, the system could work in ranges of refrigeration or air-conditioning end-uses, whose operation makes this control technique an attractive option to be implemented in the solar absorption cooling system.