na Lee

Dr. na Lee


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2018 in Sensors
Verified
Journal Article
Open access
PDF file
HPHeekyeong Park
Heekyeong Park
SLSungho Lee
Sungho Lee
SJSeok Hwan Jeong
Seok Hwan Jeong
UJUi Hyun Jung
Ui Hyun Jung
KPKidong Park
Kidong Park
JLJoonhyung Lee
Joonhyung Lee
Flexible sensors connected to cell phones are a promising technology that can aid in continuously monitoring signals in our daily lives, such as an individual’s health status and information from buildings, farms, and industry. Among such signals, real-time humidity monitoring is crucial to a comfortable life, as human bodies, plants, and industrial environments require appropriate humidity to be maintained. We propose a hydrophilic polytetrafluoroethylene (H-PTFE)-based flexible humidity sensor integrated with readout circuitry, wireless communication, and a mobile battery. To enhance its sensitivity, linearity, and reliability, treatment with sodium hydroxide implements additional hydroxyl (OH) groups, which further enhance the sensitivity, create a strong linearity with respect to variations in relative humidity, and produce a relatively free hysteresis. Furthermore, to create robust mechanical stability, cyclic upward bending was performed for up to 3000 cycles. The overall electrical and mechanical results demonstrate that the flexible real-time H-PTFE humidity sensor system is suitable for applications such as wearable smart devices.

6 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Heejung KimHeejung Kim
Heejung Kim
SKSunkook Kim
Sunkook Kim
NLna Lee
na Lee
YRYumie Rhee
Yumie Rhee
SLSungho Lee
Sungho Lee
SHSoyun Hong
Soyun Hong
There is a need for continuous, non-invasive monitoring of biological data to assess health and wellbeing. Currently, many types of smart patches have been developed to continuously monitor body temperature, but few trials have been completed to evaluate psychometrics and feasibility for human subjects in real-life scenarios. The aim of this feasibility study was to evaluate the reliability, validity and usability of a smart patch measuring body temperature in healthy adults. The smart patch consisted of a fully integrated wearable wireless sensor with a multichannel temperature sensor, signal processing integrated circuit, wireless communication feature and a flexible battery. Thirty-five healthy adults were recruited for this test, carried out by wearing the patches on their upper chests for 24 h and checking their body temperature six times a day using infrared forehead thermometers as a gold standard for testing validity. Descriptive statistics, one-sampled and independent t-tests, Pearson’s correlation coefficients and Bland-Altman plot were examined for body temperatures between two measures. In addition, multiple linear regression, receiver operating characteristic (ROC) and qualitative content analysis were conducted. Among the 35 participants, 29 of them wore the patch for over 19 h (dropout rate: 17.14%). Mean body temperature measured by infrared forehead thermometers and smart patch ranged between 32.53 and 38.2 °C per person and were moderately correlated (r = 0.23–0.43) overall. Based on a Bland-Altman plot, approximately 94% of the measurements were located within one standard deviation (upper limit = 4.52, lower limit = −5.82). Most outliers were identified on the first measurement and were located below the lower limit. It is appropriate to use 37.5 °C in infrared forehead temperature as a cutoff to define febrile conditions. Users’ position while checking and ambient temperature and humidity are not affected to the smart patch body temperature. Overall, the participants showed high usability and satisfaction on the survey. Few participants reported discomfort due to limited daily activity, itchy skin or detaching concerns. In conclusion, epidermal electronic sensor technologies provide a promising method for continuously monitoring individuals’ body temperatures, even in real-life situations. Our study findings show the potential for smart patches to monitoring non-febrile condition in the community.

18 November 2022 in Buildings
Verified
Journal Article
Open access
PDF file
SJsuyeon Jung
suyeon Jung
SHSowon Han
Sowon Han
NLna Lee
na Lee
HLHeangwoo Lee
Heangwoo Lee
Louvers are among the technical components considered for improving energy performance in buildings, and there has been increased interest in adapting the louver system. However, most previous studies have focused on their performance evaluation based on the width and angle of the slats, which allow for limited improvement in their efficiency. This study suggests a solar tracking-based movable louver (STML) system and examines the efficacy using a full-scale test bed. To do so, we developed a full-scale test bed and estimated the energy reduction and improvement of indoor uniformity of different types of STML systems, including vertical, horizontal, eggcrate, and hybrid. The main findings are as follows: (1) The proposed STML is a hybrid louver with four movable shafts due to its structural characteristics. The shading area is increased sequentially by controlling the length of the movable shaft adjacent to the sun through solar tracking. (2) Compared with conventional vertical and horizontal louvers, the STML can improve indoor uniformity by 5.0% and 13.9%, respectively. Unlike conventional louvers, the STML awnings are installed at the end of the daylighting window, reducing window view obstruction and creating a more pleasant indoor visual environment. (3) Compared with conventional louvers, the STML can reduce lighting and heating/cooling energy by 35.7–49.7%. These findings prove the effectiveness of the proposed system.

17 December 2023 in Energies
Verified
Journal Article
Open access
PDF file
SJsuyeon Jung
suyeon Jung
NLna Lee
na Lee
HLHeangwoo Lee
Heangwoo Lee
A light shelf is a type of natural daylight system that brings natural light from the outside into an indoor space through a reflector and a ceiling surface. The introduction of light shelves has led to studies evaluating their efficiency. However, past studies on light shelves did not consider the diversity of ceiling types when evaluating their performance. Therefore, this study derives fundamental data involving external light shelf designs by evaluating light shelf performance based on the ceiling type present using a light environment simulation method. This study analyzed the indoor illuminance distribution with Radiance to evaluate the performance according to light shelves and indoor space types. The results derived from this study are as follows: (1) In the case of a flat ceiling, the performance of an external light shelf can be improved by increasing its angle and width. However, adjusting the external light shelf angle to 30° during the middle of the season and 20° in winter is ineffective because natural light is not reflected by the ceiling surface. (2) The performance of a light shelf can be improved by increasing the slope and curvature of the ceiling types specified in this study. However, setting the light shelf angle to 30° during the middle season and to 30° and 20° in winter, when external natural light entering the indoor space is not reflected by the ceiling surface, is ineffective due to the low levels of daylight performance, regardless of the type of space. (3) To increase uniformity levels in gable ceilings and curved ceilings, it is advantageous to increase the number of reflections and diffusion areas on the ceiling’s surface due to the uniqueness of these ceiling shapes. Furthermore, the optimal external light shelf angle for these ceiling types differs from that of other types. (4) Regarding the appropriate external light shelf size according to a particular ceiling type, installing an angle-controllable external light shelf with a width of 1.2 m can improve daylight performance.

27 October 2026 in Buildings
Verified
Journal Article
Open access
PDF file
JCJiyeon Chae
Jiyeon Chae
JJJiwon Jang
Jiwon Jang
NLna Lee
na Lee
JSJanghoo Seo
Janghoo Seo
HLHeangwoo Lee
Heangwoo Lee
Underground spaces often experience poor luminous conditions because daylight access is limited. Although a light well (LiW) can introduce daylight, its passive geometry may not provide stable illuminance under seasonal changes in solar altitude and azimuth. This study proposes an active multistage light shelf (LiS) integrated with an LiW to improve daylight penetration and indoor luminous conditions. A Radiance-based model was validated using a 1/5 scale model, yielding a normalized mean bias error of +7.0% and a coefficient of variation of the root mean square error of 22.4%. The system was then evaluated under representative summer solstice, equinox, and winter solstice conditions using 300 and 500 lx illuminance thresholds, uniformity ratio (UR), useful daylight illuminance (UDI), and daylight-linked lighting reduction potential. A lower light shelf improved performance during the summer solstice but was less effective at lower solar altitudes. Combining upper and lower active shelves provided two-stage daylight redirection and improved daylight penetration, target illuminance satisfaction, UR, and UDI compared with the baseline and single-shelf cases. The results indicate that an active dual-shelf configuration can improve daylighting performance under the three representative seasonal conditions evaluated in this study.

28 November 2025 in Buildings
Verified
Journal Article
Open access
PDF file
SHSowon Han
Sowon Han
NLna Lee
na Lee
THTaegon Han
Taegon Han
JSJanghoo Seo
Janghoo Seo
HLHeangwoo Lee
Heangwoo Lee
Due to the recent increase in building energy consumption, daylighting technologies such as light ducts are becoming increasingly important. However, conventional light ducts have limitations, such as light loss, uneven illumination, and spectral distortion as the transmission distance increases, restricting the development of a comfortable lighting environment. This study developed technical alternatives for transmission and diffusion parts to overcome these limitations and improve the daylighting performance of light ducts. The performance of these alternatives was verified through testbed experiments. The proposed light duct design minimized light loss through the arrangement of multiple relay lenses in series in the transmission part and improved indoor illuminance uniformity in the diffusion part using a double-reflection structure with upper and lower reflectors. Consequently, for a transmission distance of 20 m, the average illuminance increased by ~27.3% and the uniformity improved by an average of 47.8% compared to a conventional plastic optical fiber (POF)-based light duct. Even under intense summer sunlight conditions, a transmission distance of 30 m showed a high useful daylighting illuminance (UDI) ratio and considerbly reduced glare risk, indicating characteristics favorable for maintaining a comfortable visual environment. Furthermore, the proposed light duct exhibited a spectral distribution similar to that of outdoor sunlight, demonstrating the potential to ensure the continuous spectral characteristics of natural light transmitted indoors. Finally, it also exhibited the potential to maintain its higher daylighting performance even at a transmission distance of 30 m compared to conventional technology.