Kun Zheng

Mr. Kun Zheng


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
JSJinhao Shen
Jinhao Shen
HZHua Zhang
Hua Zhang
XSXueneng Su
Xueneng Su
YGYiwen Gao
Yiwen Gao
KZKun Zheng
Kun Zheng
XLXinbo Liu
Xinbo Liu
If unplanned off-grid events occur in microgrids, stable operation is disrupted. In particular, dynamic unbalanced loads, power pulse, and voltage changes also lead to system instability. To overcome these issues, this paper develops a smooth droop control strategy for multi-functional inverters. By introducing a QPR (quasi-proportional resonant) controller, the load voltage regulator is designed to compensate for the harmonic and unbalanced voltages of microgrids. Compared with traditional strategies, the proposed multi-functional inverter can reduce voltage pulses by more than 60%, and the off-grid voltage THD (total harmonic distortion) is decreased from 7% to less than 3%. At the same time, dynamic unbalanced loads and non-linear dynamic loads are both considered, and the derived strategy achieves smoother grid-connected and off-grid switching. In grid-connected mode (the microgrid connects to the distribution network at the PCC), the peak voltages and overshoots across transitions are definitely decreased, and continuous monitoring shows that the grid’s current THD stays steadily below 3%. This meets compatibility requirements, avoids harmonic interference on distribution networks, and follows the core principle of IEC TS 62898-1:2023. The simulation and experimental results verify the effectiveness of the proposed multi-function inverter control strategy for grid-connected inverters.

28 July 2026 in Processes
Verified
Journal Article
Open access
PDF file
CLCheng Long
Cheng Long
HZHua Zhang
Hua Zhang
XSXueneng Su
Xueneng Su
YGYiwen Gao
Yiwen Gao
QXQian Xie
Qian Xie
KZKun Zheng
Kun Zheng
This paper proposes an operation-index-driven intelligent generation method for distribution network simulation models, integrating model library predefinition, multi-level equivalent modeling, and multi-agent collaboration into an automated pipeline. Three agents collaborate through a unified message bus, task queue, and device model library as follows: Monitor Agent performs time-series data acquisition, national-standard threshold evaluation, and topology verification to trigger modeling tasks; Energy-flow-Model Agent uses a hierarchical model library and LLM (Large Language Model) to automatically match standardized models, parses CIM topology, and applies Thevenin/Ward/three-phase admittance matrix multi-level equivalent modeling to construct Energy Flow Network (EFN) computation graphs; Device-Model-Data Agent supplies missing impedance parameters via a public device standard library. The pipeline automatically generates 15 min granularity current-state assessment models synchronized with operating conditions. Validation on eight consecutive days of 10 kV feeder field measurements (96-time sections/day, 91 transformer areas) shows three-phase voltage mean MAPE of 2.52% and 98.9% correct trigger rate with no false activations or missed detections, achieving end-to-end automation from archive parsing to model generation.

17 July 2026 in Processes
Verified
Journal Article
Open access
PDF file
CLCheng Long
Cheng Long
HZHua Zhang
Hua Zhang
XSXueneng Su
Xueneng Su
YGYiwen Gao
Yiwen Gao
QXQian Xie
Qian Xie
KZKun Zheng
Kun Zheng
To address the two fundamental contradictions in distribution network digital simulation systems: “diversified simulation requirements versus standardized configuration” and “massive simulation outputs versus sparse decision-making information”, this paper builds upon existing work on Common Information Model (CIM)-based automatic simulation model generation and dynamic voltage regulation simulation and further constructs a user-oriented intelligent simulation service layer. This layer is collaboratively composed of an Orchestration_Agent (simulation orchestration agent) and an Analysis_Agent (result analysis agent), tasked with three responsibilities: based on multi-level simulation granularity (L0–L3) and a simulation template library, leveraging a large language model (LLM) to achieve natural language requirements parsing and automatic workflow orchestration; based on a simulation knowledge graph, implementing parameter recommendation, verification, and anomaly-adaptive recovery for process control; and based on a hybrid architecture of rule templates, statistical analysis, and causal graph models, achieving automatic result analysis, root cause reasoning, and structured report generation, with case feedback driving knowledge base iteration. Validation was conducted on data from a real 10 kV feeder with 91 distribution transformer areas over 30 consecutive days (2880 time cross-sections): comprehensive requirements-parsing accuracy of 96.3%, automatic parameter configuration coverage rate of 94.7%, anomaly identification recall/precision of 94.0%/96.9%, root cause reasoning accuracy of 92.1%, and the median end-to-end time per simulation shortened from approximately 36 min under the manual mode to 4.7 min. The results demonstrate that the proposed service layer provides a viable engineering technology pathway for the evolution of distribution network simulation from tool-oriented to service-oriented.

16 September 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JSJinhao Shen
Jinhao Shen
HZHua Zhang
Hua Zhang
XSXueneng Su
Xueneng Su
YGYiwen Gao
Yiwen Gao
KZKun Zheng
Kun Zheng
XLXinbo Liu
Xinbo Liu
Nonlinear and asymmetrical loads in microgrids cause severe current distortion and phase unbalance, presenting critical challenges for grid-connected energy storage inverters. Conventional dq-frame Linear Active Disturbance Rejection Control (LADRC) suffers from two key limitations: bandwidth coupling between the observer and controller, and insufficient AC disturbance attenuation. To address these issues, an improved Quasi-Proportional Resonant-LADRC (QPR-LADRC) strategy is proposed for the inner current loop. First, by reconfiguring the disturbance feedback structure within the Linear Extended State Observer (LESO), observer bandwidth is decoupled from controller bandwidth, eliminating parameter tuning conflicts. Second, parallel QPR units tuned at 2ω0 and 6ω0 are integrated into the LESO state-error feedback loop to construct a QPR-LESO. This provides high selective gain for dq-frame AC ripples, enabling zero steady-state error tracking for negative-sequence components and dominant 5th/7th harmonics. Validated via MATLAB/Simulink and StarSim Hardware-in-the-Loop (HIL) testing, the proposed strategy restricts grid-connected current Total Harmonic Distortion (THD) below 2.7% (2.61%, 2.54%, and 2.63% for phases A, B, and C) under severe nonlinear and unbalanced loads. Compared with conventional PI and conventional LADRC schemes, it achieves maximum THD reductions of 1.68% and 3.43%, respectively, while maintaining three-phase current unbalance below 1.1%.

23 July 2026 in Processes
Verified
Journal Article
Open access
PDF file
HZHua Zhang
Hua Zhang
CLCheng Long
Cheng Long
XSXueneng Su
Xueneng Su
YGYiwen Gao
Yiwen Gao
QXQian Xie
Qian Xie
KZKun Zheng
Kun Zheng
This paper proposes a dynamic intelligent method for voltage violation management in high-renewable-penetration distribution networks. The method employs a dual-agent architecture: DERMS_Agent coordinates task scheduling, data management, and computational resource allocation, while Solution_Agent performs three-phase unbalanced power flow calculation and MIQP-based voltage violation joint optimization. Four key technical contributions are presented. (i) An asymmetric nodal admittance matrix is developed to incorporate transformer tap-phase-shift and capacitor branches within a unified formulation. (ii) Five categories of analytical sensitivities are systematically derived, covering transformer tap, phase shift, and capacitor compensation effects for both voltage regulation and harmonic suppression. (iii) A three-parameter MIQP joint optimization model is constructed with voltage deviation minimization as the objective and three-phase unbalance and resonance avoidance as constraints. (iv) A two-stage hybrid solution strategy combining Ipopt continuous relaxation with Gurobi neighborhood enumeration is designed to achieve real-time solvability. Validation on a real 10 kV feeder with 91 transformer areas over 768 time sections (8 days) demonstrates a 95.6% voltage violation resolution rate within the first three polling cycles and an average single-section solution time of 0.83 s, satisfying the real-time requirements of 15 min operational control cycles.