Fang Cheng

Fang Cheng


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2021 in Photonics
Verified
Journal Article
Open access
PDF file
QYQing YU
Qing YU
YZYali Zhang
Yali Zhang
WSWenjian Shang
Wenjian Shang
SDShengchao Dong
Shengchao Dong
CWChong Wang
Chong Wang
FCFang Cheng
Fang Cheng
Chromatic confocal microscopy is a widely used method to measure the thickness of transparent specimens. In conventional configurations, both the illumination and imaging axes are perpendicular to the test specimen. The reflection will be very weak when measuring high-transparency specimens. In order to overcome this limitation, a special chromatic confocal measuring system was developed based on inclined illumination. This design was able to significantly improve the signal-to-noise ratio. Compared with conventional designs, the proposed system was also featured by its biaxial optical scheme, instead of a coaxial one. This biaxial design improved the flexibility of the system and also increased the energy efficiency by avoiding light beam splitting. Based on this design, a prototype was built by the authors’ team. In this paper, the theoretical model of this specially designed chromatic confocal system is analyzed, and the calculating formula for the thickness of transparent specimen is provided accordingly. In order to verify its measurement performance, two experimental methodology and results are presented. The experimental results show that the repeatability is better than 0.54 μm, and the axial measurement accuracy of the system could reach the micron level.

4 March 2022 in Photonics
Verified
Journal Article
Open access
PDF file
QYQing YU
Qing YU
CWChong Wang
Chong Wang
YZYali Zhang
Yali Zhang
SHShengming Hu
Shengming Hu
TLTing Liu
Ting Liu
LXLin Xi
Lin Xi
As a fast, high-accuracy and non-contact method, chromatic confocal microscopy is widely used in micro dimensional measurement. In this area, thickness measurement for transparent specimen is one of the typical applications. In conventional coaxial illumination mode, both the illumination and imaging axes are perpendicular to the test specimen. At the same time, there are also geometric measurement limitations in conventional mode. When measuring high-transparency specimen, the energy efficiency will be quite low, and the reflection will be very weak. This limitation will significantly affect the signal-to-noise ratio. The inclined illumination mode is a good solution to overcome this bottleneck, but the thickness results may vary at different axial positions of the sample. In this paper, an error correction method for thickness measurement of transparent samples is proposed. In the authors’ work, the error correction model was analyzed and simulated, and the influence caused by the different axial positions of sample could be theoretically eliminated. The experimental results showed that the thickness measurement of the samples was practically usable, and the measurement errors were significantly reduced by less than 2.12%, as compared to the uncorrected system. With this error correction model, the standard deviation had decreased significantly, and the axial measurement accuracy of the system can reach the micron level. Additionally, this model has the same correction effect on the samples with different refractive indexes. Therefore, the system can realize the requirement of measurement at different axial positions.

9 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
FCFang Cheng
Fang Cheng
ZDZhou Dongfang
Zhou Dongfang
QYQing YU
Qing YU
TTTegoeh Tjahjowidodo
Tegoeh Tjahjowidodo
To improve the accuracy of the current vision-based linear displacement measurement in a large range, a new type of linear displacement sensing system, namely, image grating, is proposed in this paper. The proposed system included a patterned glass plate attached to the moving object and an ultra-low distortion lens for high-accuracy image matching. A DFT local up-sampling phase correlation method was adopted to obtain the sub-pixel translation of the patterns onto the target plate. Multiple sets of stripe patterns with different designs were located on the glass plate to expand the measurement range, based on the principle of phase correlation. In order to improve the measurement accuracy, the main errors of the image grating system were analyzed, and the nonlinear error compensation was completed based on the dynamic calibration of the pixel equivalent. The measurement results, after the error compensation, showed that the total error of the proposed system was less than 2.5 μm in the range of 60 mm, and the repeatability was within 0.16 μm, as quantified by standard deviation.

5 November 2020 in Actuators
Verified
Journal Article
Open access
PDF file
Yin WangYin Wang
Yin Wang
ZCZiyan Chen
Ziyan Chen
Yunlai ShiYunlai Shi
Yunlai Shi
CCChangcai Cui
Changcai Cui
FCFang Cheng
Fang Cheng
In order to build a motion system with high resolution, fast response, and long travel range in a probe station, a linear ultrasonic motor was investigated as an alternative to the electromagnetic counterpart in a servo system. This work focused on a longitudinal composite-mode linear ultrasonic motor for the motion servo system in a probe station. The motor was designed based on the required specifications. A finite element model was built to analyze the dynamic response of the stator. The influence of the structural parameters on the dynamic performances, i.e., sensitivity parameters, was calculated to analyze the stability of the structure. Based on these analytical works, a prototype of the stator was developed and mode testing was conducted. The experimental results showed that the proposed design was able to achieve respectable performance: Despite the dual-mode design, the frequency difference between the two working modes was minimized to 608 Hz; and the prototype could operate stably under 55.4 kHz, providing a 0.5 N load with 980 mm/s speed.

7 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YZYali Zhang
Yali Zhang
QYQing YU
Qing YU
CWChong Wang
Chong Wang
YZYaozu Zhang
Yaozu Zhang
FCFang Cheng
Fang Cheng
LXLin Xi
Lin Xi
Conventional chromatic confocal systems are mostly single-point coaxial illumination systems with a low signal-to-noise ratio, light energy utility and measurement efficiency. To overcome the above shortcomings, we propose a parallel non-coaxial-illumination chromatic-confocal-measurement system based on an optical fiber bundle. Based on the existing single-point non-coaxial-illumination system, the optical fiber bundle is used as the optical beam splitter to achieve parallel measurements. Thus, the system can yield measurements through line scanning, which greatly improves measurement efficiency. To verify the measurement performance of the system, based on the calibration experiment, the system realizes the measurement of the height of the step, the thickness of the transparent specimen and the reconstruction of the three-dimensional topography of the surface of the step and coin. The experimental results show that the measuring range of the system is 200 μm. The measurement accurcy can reach micron level, and the system can realize a good three-dimensional topography reconstruction effect.

1 January 2020 in Chinese Optics
Verified
Journal Article
Closed access
PDF file
ZJZou Jing-Wu
Zou Jing-Wu
QYQing YU
Qing YU
FCFang Cheng
Fang Cheng
The predecessor of China Optics was China Optics and Applied Optics Digest, which was founded in 1985. At that time, it was the only retrieval journal in the field of optics in China. At the end of 2008, China Optics and Applied Optics Digest was renamed 《中国光学》的前身是1985年创办的《中国光学与应用光学文摘》,当时是国内光学领域唯一的检索刊物。2008年底《中国光学与应用光学文摘》转型更名为《中国光学与应用光学》期刊,刊载内容突破了文摘的限制,正式成为学术刊物。